Performance Measurement and Control Approach of Water-to-Water Heat Pump in a Liquid State Dehumidification System
碩士 === 國立勤益科技大學 === 冷凍空調系 === 103 === This thesis has been used water source heat pump system to provide the cold- and heat-side water to achieve the dehumidification research. First, it must setup the experimental construction of water source heat pump system then it can integrate the liquid st...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2015
|
Online Access: | http://ndltd.ncl.edu.tw/handle/11054066919690866915 |
id |
ndltd-TW-103NCIT5680026 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-103NCIT56800262016-09-11T04:09:14Z http://ndltd.ncl.edu.tw/handle/11054066919690866915 Performance Measurement and Control Approach of Water-to-Water Heat Pump in a Liquid State Dehumidification System 水對水熱泵液態除濕系統性能量測及其控制策略模式之研究 Chao-Yung Huang 黃照詠 碩士 國立勤益科技大學 冷凍空調系 103 This thesis has been used water source heat pump system to provide the cold- and heat-side water to achieve the dehumidification research. First, it must setup the experimental construction of water source heat pump system then it can integrate the liquid state dehumidification system. It can measure the data of liquid state dehumidification system and analysis the operating characteristics of water source heat pump system. This heat pump system is running to use R410A refrigerant with liquid state dehumidification system cold- and heat-side heat exchanger. This heat pump system is also using adjustable speed drive to regulate compressor speed and combine with monitoring to acquire the operation data. In the experimental process, this heat pump system need a stable cold- and heat-side water supply liquid state dehumidification system to determine the performance of the heat pump operation. Then this heat pump system will be introduced into compare the PID (Proportional Integral Derivative) control algorithm approach and PI-PD (Proportional Integral - Proportional Derivative) approach, Smith predictor control approach. This study will use the Cascade control approach in the inner loop control compressor pressure and the outer loop control water temperature. This study control approach will use the Cascade Smith-PID approach, the Cascade Smith-Smith approach, and the Cascade PSO-Smith approach etc. An investigation of control approach and Cascade control approach optimal analysis. Chih-Neng Hsu 許智能 2015 學位論文 ; thesis 171 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立勤益科技大學 === 冷凍空調系 === 103 === This thesis has been used water source heat pump system to provide the cold- and heat-side water to achieve the dehumidification research. First, it must setup the experimental construction of water source heat pump system then it can integrate the liquid state dehumidification system. It can measure the data of liquid state dehumidification system and analysis the operating characteristics of water source heat pump system. This heat pump system is running to use R410A refrigerant with liquid state dehumidification system cold- and heat-side heat exchanger. This heat pump system is also using adjustable speed drive to regulate compressor speed and combine with monitoring to acquire the operation data.
In the experimental process, this heat pump system need a stable cold- and heat-side water supply liquid state dehumidification system to determine the performance of the heat pump operation. Then this heat pump system will be introduced into compare the PID (Proportional Integral Derivative) control algorithm approach and PI-PD (Proportional Integral - Proportional Derivative) approach, Smith predictor control approach. This study will use the Cascade control approach in the inner loop control compressor pressure and the outer loop control water temperature. This study control approach will use the Cascade Smith-PID approach, the Cascade Smith-Smith approach, and the Cascade PSO-Smith approach etc. An investigation of control approach and Cascade control approach optimal analysis.
|
author2 |
Chih-Neng Hsu |
author_facet |
Chih-Neng Hsu Chao-Yung Huang 黃照詠 |
author |
Chao-Yung Huang 黃照詠 |
spellingShingle |
Chao-Yung Huang 黃照詠 Performance Measurement and Control Approach of Water-to-Water Heat Pump in a Liquid State Dehumidification System |
author_sort |
Chao-Yung Huang |
title |
Performance Measurement and Control Approach of Water-to-Water Heat Pump in a Liquid State Dehumidification System |
title_short |
Performance Measurement and Control Approach of Water-to-Water Heat Pump in a Liquid State Dehumidification System |
title_full |
Performance Measurement and Control Approach of Water-to-Water Heat Pump in a Liquid State Dehumidification System |
title_fullStr |
Performance Measurement and Control Approach of Water-to-Water Heat Pump in a Liquid State Dehumidification System |
title_full_unstemmed |
Performance Measurement and Control Approach of Water-to-Water Heat Pump in a Liquid State Dehumidification System |
title_sort |
performance measurement and control approach of water-to-water heat pump in a liquid state dehumidification system |
publishDate |
2015 |
url |
http://ndltd.ncl.edu.tw/handle/11054066919690866915 |
work_keys_str_mv |
AT chaoyunghuang performancemeasurementandcontrolapproachofwatertowaterheatpumpinaliquidstatedehumidificationsystem AT huángzhàoyǒng performancemeasurementandcontrolapproachofwatertowaterheatpumpinaliquidstatedehumidificationsystem AT chaoyunghuang shuǐduìshuǐrèbèngyètàichúshīxìtǒngxìngnéngliàngcèjíqíkòngzhìcèlüèmóshìzhīyánjiū AT huángzhàoyǒng shuǐduìshuǐrèbèngyètàichúshīxìtǒngxìngnéngliàngcèjíqíkòngzhìcèlüèmóshìzhīyánjiū |
_version_ |
1718383781390319616 |