Topography Optimization and Manufacture of Soluble Microneedle Array

碩士 === 明志科技大學 === 機械工程系機械與機電工程碩士班 === 103 === The present study aimed to design a drug-delivery microneedle that could facili-tate painless drug administration using soluble materials exhibiting specific shapes and robustness. To achieve these specifications, ANSYS software was employed to ana-lyze...

Full description

Bibliographic Details
Main Authors: Yi-Cheng Yang, 楊益成
Other Authors: Kuo-Yung Hung
Format: Others
Language:zh-TW
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/95s8a3
id ndltd-TW-103MIT00657011
record_format oai_dc
spelling ndltd-TW-103MIT006570112018-05-19T04:28:26Z http://ndltd.ncl.edu.tw/handle/95s8a3 Topography Optimization and Manufacture of Soluble Microneedle Array 可溶性微針頭陣列形貌最佳化設計及製程研製 Yi-Cheng Yang 楊益成 碩士 明志科技大學 機械工程系機械與機電工程碩士班 103 The present study aimed to design a drug-delivery microneedle that could facili-tate painless drug administration using soluble materials exhibiting specific shapes and robustness. To achieve these specifications, ANSYS software was employed to ana-lyze the mechanical strength and lateral deflection critical load of the designs (pyra-mid column, triangular column, pentagon column and cone cloumn). The structural design was examined using the Taguchi method combined with critical buckling anal-ysis to identify the optimal size for the microneedle array. Mechanical strength analysis showed that when applying the same pressure, the stress among each shape of the tip was near 70 MPa error of ± 0.5 MPa, it can not dis-tinguish the difference, buckling analysis showed that the buckling load of pyramid column is 0.117 N, triangular column is 0.091 N, pentagon column was 0.087 N and cone column is 0.068 N, The analysis results indicated that pyramidal column exhib-ited superior cirtical load strength. An inclined exposure technique and micro molding method were used to fabri-cate the microneedle array. Carboxymethyl cellulose was selected as the constituents of the microneedle array. For the manufacturing process, the inclined exposure tech-nique was first employed in a laboratory to produce a pyramidal column-shaped sam-ple (base length = 320 μm, microneedle height = 650 μm, needle tip width = 15 μm) and an equilateral triangular column-shaped sample (base length = 396 μm, micronee-dle height = 650 μm, needle tip width = 15 μm). Then, high precision micro molding was employed using polydimethylsiloxane material to fabricate the female mold. Lastly, centrifugal casting was used to produce the microneedle structures. Microneedles degradation test consists of in vitro and in vivo tests, in vitro tests using Hank solution asbhuman body solution, microneedle are completely degraded within a minute,in vivo test inserts microneedles into rabbit and observe the degradation, the result was showed that it’s completely degraded in twenty-five minutes. In needle buckling load tests when pyra-mid column is forced 0.307 N which produce buckling; triangular column is forced 0.1257 N which produce buckling. Through this study confirmed that the pyramid shape needles have the better design of critical load and achieve the purpose of miceoneedles imme-diately degradation after piercing the skin. Kuo-Yung Hung Yun-Ju Chuang 洪國永 莊昀儒 2015 學位論文 ; thesis 131 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 明志科技大學 === 機械工程系機械與機電工程碩士班 === 103 === The present study aimed to design a drug-delivery microneedle that could facili-tate painless drug administration using soluble materials exhibiting specific shapes and robustness. To achieve these specifications, ANSYS software was employed to ana-lyze the mechanical strength and lateral deflection critical load of the designs (pyra-mid column, triangular column, pentagon column and cone cloumn). The structural design was examined using the Taguchi method combined with critical buckling anal-ysis to identify the optimal size for the microneedle array. Mechanical strength analysis showed that when applying the same pressure, the stress among each shape of the tip was near 70 MPa error of ± 0.5 MPa, it can not dis-tinguish the difference, buckling analysis showed that the buckling load of pyramid column is 0.117 N, triangular column is 0.091 N, pentagon column was 0.087 N and cone column is 0.068 N, The analysis results indicated that pyramidal column exhib-ited superior cirtical load strength. An inclined exposure technique and micro molding method were used to fabri-cate the microneedle array. Carboxymethyl cellulose was selected as the constituents of the microneedle array. For the manufacturing process, the inclined exposure tech-nique was first employed in a laboratory to produce a pyramidal column-shaped sam-ple (base length = 320 μm, microneedle height = 650 μm, needle tip width = 15 μm) and an equilateral triangular column-shaped sample (base length = 396 μm, micronee-dle height = 650 μm, needle tip width = 15 μm). Then, high precision micro molding was employed using polydimethylsiloxane material to fabricate the female mold. Lastly, centrifugal casting was used to produce the microneedle structures. Microneedles degradation test consists of in vitro and in vivo tests, in vitro tests using Hank solution asbhuman body solution, microneedle are completely degraded within a minute,in vivo test inserts microneedles into rabbit and observe the degradation, the result was showed that it’s completely degraded in twenty-five minutes. In needle buckling load tests when pyra-mid column is forced 0.307 N which produce buckling; triangular column is forced 0.1257 N which produce buckling. Through this study confirmed that the pyramid shape needles have the better design of critical load and achieve the purpose of miceoneedles imme-diately degradation after piercing the skin.
author2 Kuo-Yung Hung
author_facet Kuo-Yung Hung
Yi-Cheng Yang
楊益成
author Yi-Cheng Yang
楊益成
spellingShingle Yi-Cheng Yang
楊益成
Topography Optimization and Manufacture of Soluble Microneedle Array
author_sort Yi-Cheng Yang
title Topography Optimization and Manufacture of Soluble Microneedle Array
title_short Topography Optimization and Manufacture of Soluble Microneedle Array
title_full Topography Optimization and Manufacture of Soluble Microneedle Array
title_fullStr Topography Optimization and Manufacture of Soluble Microneedle Array
title_full_unstemmed Topography Optimization and Manufacture of Soluble Microneedle Array
title_sort topography optimization and manufacture of soluble microneedle array
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/95s8a3
work_keys_str_mv AT yichengyang topographyoptimizationandmanufactureofsolublemicroneedlearray
AT yángyìchéng topographyoptimizationandmanufactureofsolublemicroneedlearray
AT yichengyang kěróngxìngwēizhēntóuzhènlièxíngmàozuìjiāhuàshèjìjízhìchéngyánzhì
AT yángyìchéng kěróngxìngwēizhēntóuzhènlièxíngmàozuìjiāhuàshèjìjízhìchéngyánzhì
_version_ 1718640852481343488