The biocompatibility study of porous titanium alloy by Anodic method

碩士 === 國立高雄應用科技大學 === 機械與精密工程研究所 === 103 === Titanium and its alloys are currently used as implant materials due to their good mechanical properties, high corrosion resistance and excellent biocompatibility. In this study, anodic oxidation in a Na2SO4¬, CA and Ca-GP solution has been employed to mod...

Full description

Bibliographic Details
Main Authors: Mu-Huan Li, 李牧桓
Other Authors: Tsung-Chieh Cheng
Format: Others
Language:zh-TW
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/bk74hp
id ndltd-TW-103KUAS0693066
record_format oai_dc
spelling ndltd-TW-103KUAS06930662019-05-15T22:08:05Z http://ndltd.ncl.edu.tw/handle/bk74hp The biocompatibility study of porous titanium alloy by Anodic method 以陽極處理製備多孔鈦合金及其生物相容性之研究 Mu-Huan Li 李牧桓 碩士 國立高雄應用科技大學 機械與精密工程研究所 103 Titanium and its alloys are currently used as implant materials due to their good mechanical properties, high corrosion resistance and excellent biocompatibility. In this study, anodic oxidation in a Na2SO4¬, CA and Ca-GP solution has been employed to modify the structure and bioactivity of the biomedical Ti6Al4V alloy. The electrolyte solution allows for the production of bioactive titanium films to enhance its bone-forming function,hence increasing the efficacy of the orthopedic implant. After being treated with anodic oxidation treatment and soaked in simulated body fluid (SBF), the Ti6Al4V alloy was able to induce the formation of apatite on its surface. The films were investigated by means of scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), XRD and X-ray photoelectron spectrometer (XPS) to determine morphology and chemical composition of the surface layer and characterize structure, surface bonding and atomic composition before and after being soaked in SBF . The results showed that anodic oxidation in a Na2SO4, CA and Ca-GP solution can be employed to produce crystalline titanium films on Ti6Al4V surfaces. which will then induce the formation of hydroxyapatite in simulated body fluid (SBF). Additionally, the hydroxyapatite-forming ability of the films obtained through anodic oxidation has been shown to increase with the increase of the concentration of Na2SO4 in the solution. The same increase resulted in an increase of porosity and number of pores and a decrease of their size. The average diameter of the pores is within 80nm~160nm. The electrolyte solution used was made of Na2SO4 and allowed for the formation of more and smaller holes, if compared with the solution without Na2SO4. As a consequence, the oxidation capacity of the solution with Na2SO4 resulted better than that of the solution without Na2SO4. After soaking the alloy in simulated body fluid (SBF), the presence of Na2SO4 in the solution was shown to induce a faster growth of hydroxyl-apatite on its surface. On the other hand, more time is required to induce the growth of hydroxyl-apatite if the solution does not contain Na2SO4. The hydroxyapatite film formed after soaking the alloy in SBF for 14 days was 5.78 μm thick. To conclude, the anodic oxidation in a Na2SO4¬, CA and Ca-GP solution can be seen as an effective way to prepare a bioactive Ti6Al4V alloy. Tsung-Chieh Cheng 鄭宗杰 2015 學位論文 ; thesis 130 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立高雄應用科技大學 === 機械與精密工程研究所 === 103 === Titanium and its alloys are currently used as implant materials due to their good mechanical properties, high corrosion resistance and excellent biocompatibility. In this study, anodic oxidation in a Na2SO4¬, CA and Ca-GP solution has been employed to modify the structure and bioactivity of the biomedical Ti6Al4V alloy. The electrolyte solution allows for the production of bioactive titanium films to enhance its bone-forming function,hence increasing the efficacy of the orthopedic implant. After being treated with anodic oxidation treatment and soaked in simulated body fluid (SBF), the Ti6Al4V alloy was able to induce the formation of apatite on its surface. The films were investigated by means of scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), XRD and X-ray photoelectron spectrometer (XPS) to determine morphology and chemical composition of the surface layer and characterize structure, surface bonding and atomic composition before and after being soaked in SBF . The results showed that anodic oxidation in a Na2SO4, CA and Ca-GP solution can be employed to produce crystalline titanium films on Ti6Al4V surfaces. which will then induce the formation of hydroxyapatite in simulated body fluid (SBF). Additionally, the hydroxyapatite-forming ability of the films obtained through anodic oxidation has been shown to increase with the increase of the concentration of Na2SO4 in the solution. The same increase resulted in an increase of porosity and number of pores and a decrease of their size. The average diameter of the pores is within 80nm~160nm. The electrolyte solution used was made of Na2SO4 and allowed for the formation of more and smaller holes, if compared with the solution without Na2SO4. As a consequence, the oxidation capacity of the solution with Na2SO4 resulted better than that of the solution without Na2SO4. After soaking the alloy in simulated body fluid (SBF), the presence of Na2SO4 in the solution was shown to induce a faster growth of hydroxyl-apatite on its surface. On the other hand, more time is required to induce the growth of hydroxyl-apatite if the solution does not contain Na2SO4. The hydroxyapatite film formed after soaking the alloy in SBF for 14 days was 5.78 μm thick. To conclude, the anodic oxidation in a Na2SO4¬, CA and Ca-GP solution can be seen as an effective way to prepare a bioactive Ti6Al4V alloy.
author2 Tsung-Chieh Cheng
author_facet Tsung-Chieh Cheng
Mu-Huan Li
李牧桓
author Mu-Huan Li
李牧桓
spellingShingle Mu-Huan Li
李牧桓
The biocompatibility study of porous titanium alloy by Anodic method
author_sort Mu-Huan Li
title The biocompatibility study of porous titanium alloy by Anodic method
title_short The biocompatibility study of porous titanium alloy by Anodic method
title_full The biocompatibility study of porous titanium alloy by Anodic method
title_fullStr The biocompatibility study of porous titanium alloy by Anodic method
title_full_unstemmed The biocompatibility study of porous titanium alloy by Anodic method
title_sort biocompatibility study of porous titanium alloy by anodic method
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/bk74hp
work_keys_str_mv AT muhuanli thebiocompatibilitystudyofporoustitaniumalloybyanodicmethod
AT lǐmùhuán thebiocompatibilitystudyofporoustitaniumalloybyanodicmethod
AT muhuanli yǐyángjíchùlǐzhìbèiduōkǒngtàihéjīnjíqíshēngwùxiāngróngxìngzhīyánjiū
AT lǐmùhuán yǐyángjíchùlǐzhìbèiduōkǒngtàihéjīnjíqíshēngwùxiāngróngxìngzhīyánjiū
AT muhuanli biocompatibilitystudyofporoustitaniumalloybyanodicmethod
AT lǐmùhuán biocompatibilitystudyofporoustitaniumalloybyanodicmethod
_version_ 1719124994243428352