Clinical comparision of two image guidance methods for breast cancer treatment : 4D CBCT versus 2D PlanarView

碩士 === 高雄醫學大學 === 醫學影像暨放射科學系碩士在職專班 === 103 === Verification images are applied clinically before radiation treatment to ensure the accuracy of isocenter localization. The setup errors are recorded and corrected by calculating the displacement of the isocenter location on treatment setup and CT sim...

Full description

Bibliographic Details
Main Authors: Peng-Hao Chen, 陳鵬壕
Other Authors: Pao-Hsu Chang
Format: Others
Language:zh-TW
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/mhz75g
id ndltd-TW-103KMC05770005
record_format oai_dc
spelling ndltd-TW-103KMC057700052019-05-15T22:18:03Z http://ndltd.ncl.edu.tw/handle/mhz75g Clinical comparision of two image guidance methods for breast cancer treatment : 4D CBCT versus 2D PlanarView 比較四維錐狀射束電腦斷層與二維千伏X射線影像對於乳癌影像導引放射治療的相關性 Peng-Hao Chen 陳鵬壕 碩士 高雄醫學大學 醫學影像暨放射科學系碩士在職專班 103 Verification images are applied clinically before radiation treatment to ensure the accuracy of isocenter localization. The setup errors are recorded and corrected by calculating the displacement of the isocenter location on treatment setup and CT simulation. This study examined images of breast cancer patient was taken with the two most commonly used image-guided verification techniques, cone beam CT and X-ray orthogonal images. Localization errors in three axes (the caudal/cephalad, anterior/ posterior, and left/right axes) were recorded and analyzed. 11 patients with breast cancer were treated with image-guided radiotherapy with an Elekta Synergy linear accelerator. Images were taken with 4D CBCT and 2D X-ray prior to treatment. Magnitude of displacements along the three directional axes was measured. Distributions of the data were analyzed using Mann Whitney U test to define significance. Spearman’s rank correlation was used to measure the degree of association of these displacements between the two sets of images. From the analysis of the positioning X-ray orthogonal radiographs, results showed that the mean setup displacements and standard deviations were -0.05±2.45 mm, 1.83±4.38 mm, and -0.36±2.38 mm for left/right (X axis), cranial/caudal (Y axis) and anterior/posterior (Z axis) directions respectively. The mean setup displacements and standard deviations from the CBCT images when referenced to the CT simulation position were -0.12±1.97 mm, 0.65±4.52 mm and 0.64±2.08 mm for left/right (X axis)﹐cranial/caudal (Y axis) and anterior/posterior (Z axis) directions respectively. The p values for X,Y,Z axis calculated using Mann Whitney U test were 0.892, 0.003, and 0.0 for the two different sets of images. The Spearman rank correlation coefficient was 0.528, 0.741 and 0.345, with p values of 0, 0, 0.01 for X, Y, and Z axis respectively. For both image sets, the largest displacement was found in the cranial/caudal direction (Y axis). The variations along the Y axis and Z axis are statistically significant in 4D CBCT that take respiratory cycle in account and in 2D kV radiographs. Spearman''s rank correlation coefficient revealed a positively correlated relationship between the displacements along all the three axes from these two different image-guided techniques but differ in magnitude. Pao-Hsu Chang 張寶樹 2015 學位論文 ; thesis 53 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 高雄醫學大學 === 醫學影像暨放射科學系碩士在職專班 === 103 === Verification images are applied clinically before radiation treatment to ensure the accuracy of isocenter localization. The setup errors are recorded and corrected by calculating the displacement of the isocenter location on treatment setup and CT simulation. This study examined images of breast cancer patient was taken with the two most commonly used image-guided verification techniques, cone beam CT and X-ray orthogonal images. Localization errors in three axes (the caudal/cephalad, anterior/ posterior, and left/right axes) were recorded and analyzed. 11 patients with breast cancer were treated with image-guided radiotherapy with an Elekta Synergy linear accelerator. Images were taken with 4D CBCT and 2D X-ray prior to treatment. Magnitude of displacements along the three directional axes was measured. Distributions of the data were analyzed using Mann Whitney U test to define significance. Spearman’s rank correlation was used to measure the degree of association of these displacements between the two sets of images. From the analysis of the positioning X-ray orthogonal radiographs, results showed that the mean setup displacements and standard deviations were -0.05±2.45 mm, 1.83±4.38 mm, and -0.36±2.38 mm for left/right (X axis), cranial/caudal (Y axis) and anterior/posterior (Z axis) directions respectively. The mean setup displacements and standard deviations from the CBCT images when referenced to the CT simulation position were -0.12±1.97 mm, 0.65±4.52 mm and 0.64±2.08 mm for left/right (X axis)﹐cranial/caudal (Y axis) and anterior/posterior (Z axis) directions respectively. The p values for X,Y,Z axis calculated using Mann Whitney U test were 0.892, 0.003, and 0.0 for the two different sets of images. The Spearman rank correlation coefficient was 0.528, 0.741 and 0.345, with p values of 0, 0, 0.01 for X, Y, and Z axis respectively. For both image sets, the largest displacement was found in the cranial/caudal direction (Y axis). The variations along the Y axis and Z axis are statistically significant in 4D CBCT that take respiratory cycle in account and in 2D kV radiographs. Spearman''s rank correlation coefficient revealed a positively correlated relationship between the displacements along all the three axes from these two different image-guided techniques but differ in magnitude.
author2 Pao-Hsu Chang
author_facet Pao-Hsu Chang
Peng-Hao Chen
陳鵬壕
author Peng-Hao Chen
陳鵬壕
spellingShingle Peng-Hao Chen
陳鵬壕
Clinical comparision of two image guidance methods for breast cancer treatment : 4D CBCT versus 2D PlanarView
author_sort Peng-Hao Chen
title Clinical comparision of two image guidance methods for breast cancer treatment : 4D CBCT versus 2D PlanarView
title_short Clinical comparision of two image guidance methods for breast cancer treatment : 4D CBCT versus 2D PlanarView
title_full Clinical comparision of two image guidance methods for breast cancer treatment : 4D CBCT versus 2D PlanarView
title_fullStr Clinical comparision of two image guidance methods for breast cancer treatment : 4D CBCT versus 2D PlanarView
title_full_unstemmed Clinical comparision of two image guidance methods for breast cancer treatment : 4D CBCT versus 2D PlanarView
title_sort clinical comparision of two image guidance methods for breast cancer treatment : 4d cbct versus 2d planarview
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/mhz75g
work_keys_str_mv AT penghaochen clinicalcomparisionoftwoimageguidancemethodsforbreastcancertreatment4dcbctversus2dplanarview
AT chénpéngháo clinicalcomparisionoftwoimageguidancemethodsforbreastcancertreatment4dcbctversus2dplanarview
AT penghaochen bǐjiàosìwéizhuīzhuàngshèshùdiànnǎoduàncéngyǔèrwéiqiānfúxshèxiànyǐngxiàngduìyúrǔáiyǐngxiàngdǎoyǐnfàngshèzhìliáodexiāngguānxìng
AT chénpéngháo bǐjiàosìwéizhuīzhuàngshèshùdiànnǎoduàncéngyǔèrwéiqiānfúxshèxiànyǐngxiàngduìyúrǔáiyǐngxiàngdǎoyǐnfàngshèzhìliáodexiāngguānxìng
_version_ 1719128311986126848