Influence of Synchronous Generator Parameterson Power System Stability
碩士 === 義守大學 === 電機工程學系 === 103 === In this thesis, the influence of parameters change in the synchronous generator power system to the power system stability is discussed. The system includes synchronous generator, 5MW load, three-phase transformer, 10MW load, three-phase ground fault and the grid....
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2015
|
Online Access: | http://ndltd.ncl.edu.tw/handle/20222662119869115227 |
id |
ndltd-TW-103ISU05442002 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-103ISU054420022016-08-28T04:11:48Z http://ndltd.ncl.edu.tw/handle/20222662119869115227 Influence of Synchronous Generator Parameterson Power System Stability 同步發電機參數於電力系統穩定度之影響 Chia-Wen Cheng 鄭嘉文 碩士 義守大學 電機工程學系 103 In this thesis, the influence of parameters change in the synchronous generator power system to the power system stability is discussed. The system includes synchronous generator, 5MW load, three-phase transformer, 10MW load, three-phase ground fault and the grid. The system is simulated with MATLAB internal module by adjusting the parameters of exciting system and the speed governor; the transient stability performance is judged by critical clearing time, and the steady state stability is judged by observing the time domain waveform. The result shows that the system stability is acceptable while adjusting the parameters in this sort of system. The value of this thesis is to establish critical reference data of system stability while adjusting parameters in the system mentioned above. Yu-Jen Lin 林堉仁 2015 學位論文 ; thesis 48 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 義守大學 === 電機工程學系 === 103 === In this thesis, the influence of parameters change in the synchronous generator power
system to the power system stability is discussed. The system includes synchronous
generator, 5MW load, three-phase transformer, 10MW load, three-phase ground fault and
the grid. The system is simulated with MATLAB internal module by adjusting the
parameters of exciting system and the speed governor; the transient stability performance
is judged by critical clearing time, and the steady state stability is judged by observing the
time domain waveform. The result shows that the system stability is acceptable while
adjusting the parameters in this sort of system. The value of this thesis is to establish
critical reference data of system stability while adjusting parameters in the system
mentioned above.
|
author2 |
Yu-Jen Lin |
author_facet |
Yu-Jen Lin Chia-Wen Cheng 鄭嘉文 |
author |
Chia-Wen Cheng 鄭嘉文 |
spellingShingle |
Chia-Wen Cheng 鄭嘉文 Influence of Synchronous Generator Parameterson Power System Stability |
author_sort |
Chia-Wen Cheng |
title |
Influence of Synchronous Generator Parameterson Power System Stability |
title_short |
Influence of Synchronous Generator Parameterson Power System Stability |
title_full |
Influence of Synchronous Generator Parameterson Power System Stability |
title_fullStr |
Influence of Synchronous Generator Parameterson Power System Stability |
title_full_unstemmed |
Influence of Synchronous Generator Parameterson Power System Stability |
title_sort |
influence of synchronous generator parameterson power system stability |
publishDate |
2015 |
url |
http://ndltd.ncl.edu.tw/handle/20222662119869115227 |
work_keys_str_mv |
AT chiawencheng influenceofsynchronousgeneratorparametersonpowersystemstability AT zhèngjiāwén influenceofsynchronousgeneratorparametersonpowersystemstability AT chiawencheng tóngbùfādiànjīcānshùyúdiànlìxìtǒngwěndìngdùzhīyǐngxiǎng AT zhèngjiāwén tóngbùfādiànjīcānshùyúdiànlìxìtǒngwěndìngdùzhīyǐngxiǎng |
_version_ |
1718380528096247808 |