Indoor air quality and bio-aerosols distribution of a hospital in southern Taiwan
碩士 === 弘光科技大學 === 環境工程研究所 === 103 === The indoor air quality (IAQ) plays an important role in the human health and comfort ability of occupants, especially in hospitals. The nosocomial airborne contamination in hospitals can arrive from non-biological and biological sources, which in-turn causes pre...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2015
|
Online Access: | http://ndltd.ncl.edu.tw/handle/e8g938 |
id |
ndltd-TW-103HKU00515011 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-103HKU005150112019-05-15T22:08:04Z http://ndltd.ncl.edu.tw/handle/e8g938 Indoor air quality and bio-aerosols distribution of a hospital in southern Taiwan 台灣南部某醫院室內空氣品質及生物氣膠分佈研究 Shin-Yuan Wang 王信元 碩士 弘光科技大學 環境工程研究所 103 The indoor air quality (IAQ) plays an important role in the human health and comfort ability of occupants, especially in hospitals. The nosocomial airborne contamination in hospitals can arrive from non-biological and biological sources, which in-turn causes precipitating of symptoms and infecting disease in susceptible subject’s i.e. elderly or immuno-compromised subjects. For analysis and maintenance protocols to comprise the hospital IAQ within the IAQ standards, I use the Andersen single-stage viable particle sizing sampler to investigate the presence of bacteria and fungi in the indoor-air of a hospital. In addition, we intend to investigate the relationship between IAQ and various environmental factors such as CO2 concentration, temperature, relative humidity, PM10 and PM2.5. The sampling was taken place at nine specific locations in the hospital, southern Taiwan during the time period of 18 January 2014 till 5 December 2014. Form this study, we understand the bio-aerosols average concentration range at these nine area. Two different sampling was used in this specific study: the TSA technique and MEA technique. The TSA technique, the sample was kept in an incubation of 48 hours at 30 degrees. The result shows that the average concentrations of the bacteria (CFU/m3) with these specific locations (A-I) were 937±281, 805±330, 436±237, 1648±269, 1252±451, 1196±372, 1485±421, 403±108, 178±94. The MEA technique, the sample was kept in an incubation of 48 hours at 30 degrees. The fungal average concentrations (CFU/m3) were 166±65, 124±32, 189±98, 65±28, 28±19, 70±40, 106±43, 207±146, 294±124. This study has identified five different species of bacteria as Acinetobacter, Bacillus megaterium, Microbacterium, Micrococcus, Staphylococcus. The fungal species was identified as follows Aspergillus niger strain, Eutypa, Fusarium, Penicillium, Phellinus noxius, Pseudozyma. 王俊欽 2015 學位論文 ; thesis 100 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 弘光科技大學 === 環境工程研究所 === 103 === The indoor air quality (IAQ) plays an important role in the human health and comfort ability of occupants, especially in hospitals. The nosocomial airborne contamination in hospitals can arrive from non-biological and biological sources, which in-turn causes precipitating of symptoms and infecting disease in susceptible subject’s i.e. elderly or immuno-compromised subjects. For analysis and maintenance protocols to comprise the hospital IAQ within the IAQ standards, I use the Andersen single-stage viable particle sizing sampler to investigate the presence of bacteria and fungi in the indoor-air of a hospital. In addition, we intend to investigate the relationship between IAQ and various environmental factors such as CO2 concentration, temperature, relative humidity, PM10 and PM2.5.
The sampling was taken place at nine specific locations in the hospital, southern Taiwan during the time period of 18 January 2014 till 5 December 2014. Form this study, we understand the bio-aerosols average concentration range at these nine area. Two different sampling was used in this specific study: the TSA technique and MEA technique. The TSA technique, the sample was kept in an incubation of 48 hours at 30 degrees. The result shows that the average concentrations of the bacteria (CFU/m3) with these specific locations (A-I) were 937±281, 805±330, 436±237, 1648±269, 1252±451, 1196±372, 1485±421, 403±108, 178±94. The MEA technique, the sample was kept in an incubation of 48 hours at 30 degrees. The fungal average concentrations (CFU/m3) were 166±65, 124±32, 189±98, 65±28, 28±19, 70±40, 106±43, 207±146, 294±124.
This study has identified five different species of bacteria as Acinetobacter, Bacillus megaterium, Microbacterium, Micrococcus, Staphylococcus. The fungal species was identified as follows Aspergillus niger strain, Eutypa, Fusarium, Penicillium, Phellinus noxius, Pseudozyma.
|
author2 |
王俊欽 |
author_facet |
王俊欽 Shin-Yuan Wang 王信元 |
author |
Shin-Yuan Wang 王信元 |
spellingShingle |
Shin-Yuan Wang 王信元 Indoor air quality and bio-aerosols distribution of a hospital in southern Taiwan |
author_sort |
Shin-Yuan Wang |
title |
Indoor air quality and bio-aerosols distribution of a hospital in southern Taiwan |
title_short |
Indoor air quality and bio-aerosols distribution of a hospital in southern Taiwan |
title_full |
Indoor air quality and bio-aerosols distribution of a hospital in southern Taiwan |
title_fullStr |
Indoor air quality and bio-aerosols distribution of a hospital in southern Taiwan |
title_full_unstemmed |
Indoor air quality and bio-aerosols distribution of a hospital in southern Taiwan |
title_sort |
indoor air quality and bio-aerosols distribution of a hospital in southern taiwan |
publishDate |
2015 |
url |
http://ndltd.ncl.edu.tw/handle/e8g938 |
work_keys_str_mv |
AT shinyuanwang indoorairqualityandbioaerosolsdistributionofahospitalinsoutherntaiwan AT wángxìnyuán indoorairqualityandbioaerosolsdistributionofahospitalinsoutherntaiwan AT shinyuanwang táiwānnánbùmǒuyīyuànshìnèikōngqìpǐnzhìjíshēngwùqìjiāofēnbùyánjiū AT wángxìnyuán táiwānnánbùmǒuyīyuànshìnèikōngqìpǐnzhìjíshēngwùqìjiāofēnbùyánjiū |
_version_ |
1719124927876956160 |