碩士 === 逢甲大學 === 資電碩士在職專班 === 103 === The content of this thesis is to investigate the energy-saving methods of elevator controller systems. From the progress of conventional controlling speed methods, it can be used to improve the main-motor controlling efficiency. By means of motor structures and c...

Full description

Bibliographic Details
Main Authors: Cheng Kuen-Feng, 鄭坤豐
Other Authors: 劉文豐
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/15476856160458724844
id ndltd-TW-103FCU05392009
record_format oai_dc
spelling ndltd-TW-103FCU053920092016-07-31T04:22:33Z http://ndltd.ncl.edu.tw/handle/15476856160458724844 The Study of energy-saving technology for the elevator controller system 電梯控制系統節能技術之研究 Cheng Kuen-Feng 鄭坤豐 碩士 逢甲大學 資電碩士在職專班 103 The content of this thesis is to investigate the energy-saving methods of elevator controller systems. From the progress of conventional controlling speed methods, it can be used to improve the main-motor controlling efficiency. By means of motor structures and control theorem, we will use the frequency conversion technique to investigate the saving-energy reason and to recycle the unused rising-up-voltage energy. We also use the fuzzy control theory to improve the operating efficiency of the dispatching system of an elevator and to increase the sleep-saving-energy efficiency. In this thesis we proposed a novel technique of dynamic loading capacity variation based on the principle of conservation of energy and the balancing operation of 50 % loading. If every running of an elevator is the balancing operation, it not only requires the minimum electrical power and but also creates the minimum rising-up voltage for achieving the destination of saving energy. The key technique of saving energy for an elevator depends mainly on operating the facilities of control system. For the user to operate an elevator with the time and voltage/current, and button-level etc. to be recorded, the fuzzy control theory is used for finding the fuzzy controlling flag and then to tell elevator’s control unit to operate the saving-energy model operation. We also use the optimum saving-energy operating experience of 50 % balancing loading of an elevator and the dynamic varying rated-loading for reaching the maximum saving energy. Keywords: elevator control system, saving energy, frequency conversion technique, rising-up voltage, fuzzy control, control flag, and dynamic loading-capacity. 劉文豐 2014 學位論文 ; thesis 194 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 逢甲大學 === 資電碩士在職專班 === 103 === The content of this thesis is to investigate the energy-saving methods of elevator controller systems. From the progress of conventional controlling speed methods, it can be used to improve the main-motor controlling efficiency. By means of motor structures and control theorem, we will use the frequency conversion technique to investigate the saving-energy reason and to recycle the unused rising-up-voltage energy. We also use the fuzzy control theory to improve the operating efficiency of the dispatching system of an elevator and to increase the sleep-saving-energy efficiency. In this thesis we proposed a novel technique of dynamic loading capacity variation based on the principle of conservation of energy and the balancing operation of 50 % loading. If every running of an elevator is the balancing operation, it not only requires the minimum electrical power and but also creates the minimum rising-up voltage for achieving the destination of saving energy. The key technique of saving energy for an elevator depends mainly on operating the facilities of control system. For the user to operate an elevator with the time and voltage/current, and button-level etc. to be recorded, the fuzzy control theory is used for finding the fuzzy controlling flag and then to tell elevator’s control unit to operate the saving-energy model operation. We also use the optimum saving-energy operating experience of 50 % balancing loading of an elevator and the dynamic varying rated-loading for reaching the maximum saving energy. Keywords: elevator control system, saving energy, frequency conversion technique, rising-up voltage, fuzzy control, control flag, and dynamic loading-capacity.
author2 劉文豐
author_facet 劉文豐
Cheng Kuen-Feng
鄭坤豐
author Cheng Kuen-Feng
鄭坤豐
spellingShingle Cheng Kuen-Feng
鄭坤豐
The Study of energy-saving technology for the elevator controller system
author_sort Cheng Kuen-Feng
title The Study of energy-saving technology for the elevator controller system
title_short The Study of energy-saving technology for the elevator controller system
title_full The Study of energy-saving technology for the elevator controller system
title_fullStr The Study of energy-saving technology for the elevator controller system
title_full_unstemmed The Study of energy-saving technology for the elevator controller system
title_sort study of energy-saving technology for the elevator controller system
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/15476856160458724844
work_keys_str_mv AT chengkuenfeng thestudyofenergysavingtechnologyfortheelevatorcontrollersystem
AT zhèngkūnfēng thestudyofenergysavingtechnologyfortheelevatorcontrollersystem
AT chengkuenfeng diàntīkòngzhìxìtǒngjiénéngjìshùzhīyánjiū
AT zhèngkūnfēng diàntīkòngzhìxìtǒngjiénéngjìshùzhīyánjiū
AT chengkuenfeng studyofenergysavingtechnologyfortheelevatorcontrollersystem
AT zhèngkūnfēng studyofenergysavingtechnologyfortheelevatorcontrollersystem
_version_ 1718367770497777664