The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom
碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 103 === Recently, dental computed tomography has become the important examination before dental implantations. This examination wasto simulate the implantation performed with an image guide system.Previous researches indicated that there...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2015
|
Online Access: | http://ndltd.ncl.edu.tw/handle/09166335760349479923 |
id |
ndltd-TW-103CTC00770033 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-103CTC007700332016-12-04T04:07:59Z http://ndltd.ncl.edu.tw/handle/09166335760349479923 The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom 運用擬人假體評估牙科電腦斷層對腦膜造成之輻射劑量 Hsu, Wei-Cheng 徐暐程 碩士 中臺科技大學 醫學影像暨放射科學系暨研究所 103 Recently, dental computed tomography has become the important examination before dental implantations. This examination wasto simulate the implantation performed with an image guide system.Previous researches indicated that there are higher probability of meningiomas for patients underwent dental computed tomography. Therefore, this study used an anthropomorphic Rando phantom with TLDs and Gafchromic film to measure the absorbed dose of themeninges area in the brain. The data was analyzed to discuss the risk for meningioma resulting from the dental computed tomography examinations. The results showed 0.14mSv from TLD and 0.12mSv from film. Calculation was done based on ICRP 103 with nominal risk coefficient of 5.7%Sv-1, the risk of stochastic effect for patient undergoing dentalcomputed tomography were 0.0008% from TLD and 0.0007% from film. Based on the effective dose contribution obtained from both radiation detectors, estimated stochastic effect and radiation risk were relatively low. The effective dose contributions for meninges were only8% (Gafchromic film)and 7% (TLD). Therefore, it is concluded that the impact of dental computed tomography on the causing of meningiomas would be minimal. Cheng, Kai-Yuan 鄭凱元 2015 學位論文 ; thesis 72 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 103 === Recently, dental computed tomography has become the important examination before dental implantations. This examination wasto simulate the implantation performed with an image guide system.Previous researches indicated that there are higher probability of meningiomas for patients underwent dental computed tomography. Therefore, this study used an anthropomorphic Rando phantom with TLDs and Gafchromic film to measure the absorbed dose of themeninges area in the brain. The data was analyzed to discuss the risk for meningioma resulting from the dental computed tomography examinations. The results showed 0.14mSv from TLD and 0.12mSv from film. Calculation was done based on ICRP 103 with nominal risk coefficient of 5.7%Sv-1, the risk of stochastic effect for patient undergoing dentalcomputed tomography were 0.0008% from TLD and 0.0007% from film. Based on the effective dose contribution obtained from both radiation detectors, estimated stochastic effect and radiation risk were relatively low. The effective dose contributions for meninges were only8% (Gafchromic film)and 7% (TLD). Therefore, it is concluded that the impact of dental computed tomography on the causing of meningiomas would be minimal.
|
author2 |
Cheng, Kai-Yuan |
author_facet |
Cheng, Kai-Yuan Hsu, Wei-Cheng 徐暐程 |
author |
Hsu, Wei-Cheng 徐暐程 |
spellingShingle |
Hsu, Wei-Cheng 徐暐程 The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom |
author_sort |
Hsu, Wei-Cheng |
title |
The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom |
title_short |
The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom |
title_full |
The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom |
title_fullStr |
The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom |
title_full_unstemmed |
The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom |
title_sort |
dose evaluation of dental computed tomography in meninges area via cirs phantom |
publishDate |
2015 |
url |
http://ndltd.ncl.edu.tw/handle/09166335760349479923 |
work_keys_str_mv |
AT hsuweicheng thedoseevaluationofdentalcomputedtomographyinmeningesareaviacirsphantom AT xúwěichéng thedoseevaluationofdentalcomputedtomographyinmeningesareaviacirsphantom AT hsuweicheng yùnyòngnǐrénjiǎtǐpínggūyákēdiànnǎoduàncéngduìnǎomózàochéngzhīfúshèjìliàng AT xúwěichéng yùnyòngnǐrénjiǎtǐpínggūyákēdiànnǎoduàncéngduìnǎomózàochéngzhīfúshèjìliàng AT hsuweicheng doseevaluationofdentalcomputedtomographyinmeningesareaviacirsphantom AT xúwěichéng doseevaluationofdentalcomputedtomographyinmeningesareaviacirsphantom |
_version_ |
1718398983155482624 |