The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom

碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 103 === Recently, dental computed tomography has become the important examination before dental implantations. This examination wasto simulate the implantation performed with an image guide system.Previous researches indicated that there...

Full description

Bibliographic Details
Main Authors: Hsu, Wei-Cheng, 徐暐程
Other Authors: Cheng, Kai-Yuan
Format: Others
Language:zh-TW
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/09166335760349479923
id ndltd-TW-103CTC00770033
record_format oai_dc
spelling ndltd-TW-103CTC007700332016-12-04T04:07:59Z http://ndltd.ncl.edu.tw/handle/09166335760349479923 The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom 運用擬人假體評估牙科電腦斷層對腦膜造成之輻射劑量 Hsu, Wei-Cheng 徐暐程 碩士 中臺科技大學 醫學影像暨放射科學系暨研究所 103 Recently, dental computed tomography has become the important examination before dental implantations. This examination wasto simulate the implantation performed with an image guide system.Previous researches indicated that there are higher probability of meningiomas for patients underwent dental computed tomography. Therefore, this study used an anthropomorphic Rando phantom with TLDs and Gafchromic film to measure the absorbed dose of themeninges area in the brain. The data was analyzed to discuss the risk for meningioma resulting from the dental computed tomography examinations. The results showed 0.14mSv from TLD and 0.12mSv from film. Calculation was done based on ICRP 103 with nominal risk coefficient of 5.7%Sv-1, the risk of stochastic effect for patient undergoing dentalcomputed tomography were 0.0008% from TLD and 0.0007% from film. Based on the effective dose contribution obtained from both radiation detectors, estimated stochastic effect and radiation risk were relatively low. The effective dose contributions for meninges were only8% (Gafchromic film)and 7% (TLD). Therefore, it is concluded that the impact of dental computed tomography on the causing of meningiomas would be minimal. Cheng, Kai-Yuan 鄭凱元 2015 學位論文 ; thesis 72 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 103 === Recently, dental computed tomography has become the important examination before dental implantations. This examination wasto simulate the implantation performed with an image guide system.Previous researches indicated that there are higher probability of meningiomas for patients underwent dental computed tomography. Therefore, this study used an anthropomorphic Rando phantom with TLDs and Gafchromic film to measure the absorbed dose of themeninges area in the brain. The data was analyzed to discuss the risk for meningioma resulting from the dental computed tomography examinations. The results showed 0.14mSv from TLD and 0.12mSv from film. Calculation was done based on ICRP 103 with nominal risk coefficient of 5.7%Sv-1, the risk of stochastic effect for patient undergoing dentalcomputed tomography were 0.0008% from TLD and 0.0007% from film. Based on the effective dose contribution obtained from both radiation detectors, estimated stochastic effect and radiation risk were relatively low. The effective dose contributions for meninges were only8% (Gafchromic film)and 7% (TLD). Therefore, it is concluded that the impact of dental computed tomography on the causing of meningiomas would be minimal.
author2 Cheng, Kai-Yuan
author_facet Cheng, Kai-Yuan
Hsu, Wei-Cheng
徐暐程
author Hsu, Wei-Cheng
徐暐程
spellingShingle Hsu, Wei-Cheng
徐暐程
The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom
author_sort Hsu, Wei-Cheng
title The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom
title_short The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom
title_full The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom
title_fullStr The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom
title_full_unstemmed The Dose Evaluation of Dental Computed Tomography in Meninges Area via CIRS phantom
title_sort dose evaluation of dental computed tomography in meninges area via cirs phantom
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/09166335760349479923
work_keys_str_mv AT hsuweicheng thedoseevaluationofdentalcomputedtomographyinmeningesareaviacirsphantom
AT xúwěichéng thedoseevaluationofdentalcomputedtomographyinmeningesareaviacirsphantom
AT hsuweicheng yùnyòngnǐrénjiǎtǐpínggūyákēdiànnǎoduàncéngduìnǎomózàochéngzhīfúshèjìliàng
AT xúwěichéng yùnyòngnǐrénjiǎtǐpínggūyákēdiànnǎoduàncéngduìnǎomózàochéngzhīfúshèjìliàng
AT hsuweicheng doseevaluationofdentalcomputedtomographyinmeningesareaviacirsphantom
AT xúwěichéng doseevaluationofdentalcomputedtomographyinmeningesareaviacirsphantom
_version_ 1718398983155482624