Study of range verification using PET imaging induced in proton therapy based on Monte Carlo simulation

碩士 === 長庚大學 === 醫學影像暨放射科學系 === 103 === The advantages of proton therapy, in contrast to conventional radiotherapy from photons and electrons, are based on the characteristic proton Bragg peak. However, the advantages are hampered by uncertainties in the proton range caused by many factors. As a qual...

Full description

Bibliographic Details
Main Authors: Cheng Yi Ke, 柯承邑
Other Authors: I. T. Hsiao
Format: Others
Published: 2015
Online Access:http://ndltd.ncl.edu.tw/handle/26344947838465851188
id ndltd-TW-103CGU05770011
record_format oai_dc
spelling ndltd-TW-103CGU057700112016-07-31T04:22:28Z http://ndltd.ncl.edu.tw/handle/26344947838465851188 Study of range verification using PET imaging induced in proton therapy based on Monte Carlo simulation 利用質子治療引發正子影像應用於質子劑量驗證之研究 Cheng Yi Ke 柯承邑 碩士 長庚大學 醫學影像暨放射科學系 103 The advantages of proton therapy, in contrast to conventional radiotherapy from photons and electrons, are based on the characteristic proton Bragg peak. However, the advantages are hampered by uncertainties in the proton range caused by many factors. As a quality assurance (QC) process, verification on correctness of the dose delivery and irradiation field position is necessary after proton therapy. Position emission tomography (PET) as a tool for verifying dose distribution in proton therapy after treatment has became one of the research interests among associated research groups recently. The aim of this study is to study the range difference between proton and PET activity based on Monte Carlo simulation. The results indicated that the proton dose range is dependent on PET acquisition time, and also on irradiated materials. The acquired 15O signal leads to least range difference between PET activity and proton dose range, and thus PET activity acquired from earlier scanning time frame (2-5min) is with both high-counting statistics and less biological washout. The study also showed that the three de-convolution methods are able to provide results with acceptable range errors for proton range verification. I. T. Hsiao 蕭穎聰 2015 學位論文 ; thesis 89
collection NDLTD
format Others
sources NDLTD
description 碩士 === 長庚大學 === 醫學影像暨放射科學系 === 103 === The advantages of proton therapy, in contrast to conventional radiotherapy from photons and electrons, are based on the characteristic proton Bragg peak. However, the advantages are hampered by uncertainties in the proton range caused by many factors. As a quality assurance (QC) process, verification on correctness of the dose delivery and irradiation field position is necessary after proton therapy. Position emission tomography (PET) as a tool for verifying dose distribution in proton therapy after treatment has became one of the research interests among associated research groups recently. The aim of this study is to study the range difference between proton and PET activity based on Monte Carlo simulation. The results indicated that the proton dose range is dependent on PET acquisition time, and also on irradiated materials. The acquired 15O signal leads to least range difference between PET activity and proton dose range, and thus PET activity acquired from earlier scanning time frame (2-5min) is with both high-counting statistics and less biological washout. The study also showed that the three de-convolution methods are able to provide results with acceptable range errors for proton range verification.
author2 I. T. Hsiao
author_facet I. T. Hsiao
Cheng Yi Ke
柯承邑
author Cheng Yi Ke
柯承邑
spellingShingle Cheng Yi Ke
柯承邑
Study of range verification using PET imaging induced in proton therapy based on Monte Carlo simulation
author_sort Cheng Yi Ke
title Study of range verification using PET imaging induced in proton therapy based on Monte Carlo simulation
title_short Study of range verification using PET imaging induced in proton therapy based on Monte Carlo simulation
title_full Study of range verification using PET imaging induced in proton therapy based on Monte Carlo simulation
title_fullStr Study of range verification using PET imaging induced in proton therapy based on Monte Carlo simulation
title_full_unstemmed Study of range verification using PET imaging induced in proton therapy based on Monte Carlo simulation
title_sort study of range verification using pet imaging induced in proton therapy based on monte carlo simulation
publishDate 2015
url http://ndltd.ncl.edu.tw/handle/26344947838465851188
work_keys_str_mv AT chengyike studyofrangeverificationusingpetimaginginducedinprotontherapybasedonmontecarlosimulation
AT kēchéngyì studyofrangeverificationusingpetimaginginducedinprotontherapybasedonmontecarlosimulation
AT chengyike lìyòngzhìzizhìliáoyǐnfāzhèngziyǐngxiàngyīngyòngyúzhìzijìliàngyànzhèngzhīyánjiū
AT kēchéngyì lìyòngzhìzizhìliáoyǐnfāzhèngziyǐngxiàngyīngyòngyúzhìzijìliàngyànzhèngzhīyánjiū
_version_ 1718367673866256384