A Study on Kinmen Power System protection Scheme

碩士 === 大同大學 === 電機工程學系(所) === 102 === The study is illustrate on the example of an isolated power system, Kinmen power system, consisting of diesel generators, wind turbine generators and PVs. The characteristic of renewable energy, intermittence, has potential impacts on power quality and system re...

Full description

Bibliographic Details
Main Authors: Bo-Wei Chen, 陳柏瑋
Other Authors: Bin-Kwie Chen
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/95908496871767504687
id ndltd-TW-102TTU05442002
record_format oai_dc
spelling ndltd-TW-102TTU054420022016-02-28T04:20:19Z http://ndltd.ncl.edu.tw/handle/95908496871767504687 A Study on Kinmen Power System protection Scheme 金門電力系統防衛計畫分析研究 Bo-Wei Chen 陳柏瑋 碩士 大同大學 電機工程學系(所) 102 The study is illustrate on the example of an isolated power system, Kinmen power system, consisting of diesel generators, wind turbine generators and PVs. The characteristic of renewable energy, intermittence, has potential impacts on power quality and system reliability, though it depends on the penetration of the existing renewable energy. The operator also worries about the issue and limit the wind output, especially when high penetration of wind power occurs in winter off-peak period. Installing energy storage facilities could be considered to smooth out the fluctuations and improve supply continuity. This study refers to IEC 61400-21 for power quality measurement and assessment of power quality characteristics of grid connected wind turbines, and uses the power analysis software, PSS/E, and its dynamics models for load flow analysis and transient stability analysis, which are based on the existing scheduling criteria, typical load patterns to inestigate contribution of renewable energy and energy storage to steady and dynamic responses. Therefore, provide some advice for power generation operation and control. Bin-Kwie Chen 陳斌魁 2013 學位論文 ; thesis 171 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 大同大學 === 電機工程學系(所) === 102 === The study is illustrate on the example of an isolated power system, Kinmen power system, consisting of diesel generators, wind turbine generators and PVs. The characteristic of renewable energy, intermittence, has potential impacts on power quality and system reliability, though it depends on the penetration of the existing renewable energy. The operator also worries about the issue and limit the wind output, especially when high penetration of wind power occurs in winter off-peak period. Installing energy storage facilities could be considered to smooth out the fluctuations and improve supply continuity. This study refers to IEC 61400-21 for power quality measurement and assessment of power quality characteristics of grid connected wind turbines, and uses the power analysis software, PSS/E, and its dynamics models for load flow analysis and transient stability analysis, which are based on the existing scheduling criteria, typical load patterns to inestigate contribution of renewable energy and energy storage to steady and dynamic responses. Therefore, provide some advice for power generation operation and control.
author2 Bin-Kwie Chen
author_facet Bin-Kwie Chen
Bo-Wei Chen
陳柏瑋
author Bo-Wei Chen
陳柏瑋
spellingShingle Bo-Wei Chen
陳柏瑋
A Study on Kinmen Power System protection Scheme
author_sort Bo-Wei Chen
title A Study on Kinmen Power System protection Scheme
title_short A Study on Kinmen Power System protection Scheme
title_full A Study on Kinmen Power System protection Scheme
title_fullStr A Study on Kinmen Power System protection Scheme
title_full_unstemmed A Study on Kinmen Power System protection Scheme
title_sort study on kinmen power system protection scheme
publishDate 2013
url http://ndltd.ncl.edu.tw/handle/95908496871767504687
work_keys_str_mv AT boweichen astudyonkinmenpowersystemprotectionscheme
AT chénbǎiwěi astudyonkinmenpowersystemprotectionscheme
AT boweichen jīnméndiànlìxìtǒngfángwèijìhuàfēnxīyánjiū
AT chénbǎiwěi jīnméndiànlìxìtǒngfángwèijìhuàfēnxīyánjiū
AT boweichen studyonkinmenpowersystemprotectionscheme
AT chénbǎiwěi studyonkinmenpowersystemprotectionscheme
_version_ 1718195938556641280