Performance Analysis of Variable Speed Pump Systems by Applying Bernoulli Equation
碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 102 === The energy consumed by air conditioning system for general commercial building is about 40~50% of the total energy consumption, therefore, there is still a lot of room for energy saving on air conditioning system. Popular energy saving method includes us...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/tn778e |
id |
ndltd-TW-102TIT05703034 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102TIT057030342019-05-15T21:42:32Z http://ndltd.ncl.edu.tw/handle/tn778e Performance Analysis of Variable Speed Pump Systems by Applying Bernoulli Equation 柏努利方程式應用於空調變頻泵浦配管系統之計算與分析 Chien-Cheng Shih 施建成 碩士 國立臺北科技大學 能源與冷凍空調工程系碩士班 102 The energy consumed by air conditioning system for general commercial building is about 40~50% of the total energy consumption, therefore, there is still a lot of room for energy saving on air conditioning system. Popular energy saving method includes using variable air volume for fan system and using variable water volume for pump system. The system speed will adjust air and water volume according to the loading to optimize energy consumption. Fan and pump of air conditioning system are both in the field of fluid mechanics where fan affinity laws and pump affinity laws are applicable. There is a cubic relationship between the shaft horsepower in theoretical affinity law and the shaft horsepower in variable air volume and variable water volume. However, in reality, the difference between real shaft horsepower and theoretical shaft horsepower is significant. This study will simulate and calculate the energy consumption at one operating point in an air conditioning variable speed pump piping system and come up with the energy consumption in all operating points in the system by using Bernoulli''s equation. The result will be compared with the theoretical energy consumption calculated by using pump affinity laws and derive a formula for the energy consumption of air conditioning variable speed pump piping system. 柯明村 2014 學位論文 ; thesis 70 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 102 === The energy consumed by air conditioning system for general commercial building is about 40~50% of the total energy consumption, therefore, there is still a lot of room for energy saving on air conditioning system. Popular energy saving method includes using variable air volume for fan system and using variable water volume for pump system. The system speed will adjust air and water volume according to the loading to optimize energy consumption.
Fan and pump of air conditioning system are both in the field of fluid mechanics where fan affinity laws and pump affinity laws are applicable. There is a cubic relationship between the shaft horsepower in theoretical affinity law and the shaft horsepower in variable air volume and variable water volume. However, in reality, the difference between real shaft horsepower and theoretical shaft horsepower is significant.
This study will simulate and calculate the energy consumption at one operating point in an air conditioning variable speed pump piping system and come up with the energy consumption in all operating points in the system by using Bernoulli''s equation. The result will be compared with the theoretical energy consumption calculated by using pump affinity laws and derive a formula for the energy consumption of air conditioning variable speed pump piping system.
|
author2 |
柯明村 |
author_facet |
柯明村 Chien-Cheng Shih 施建成 |
author |
Chien-Cheng Shih 施建成 |
spellingShingle |
Chien-Cheng Shih 施建成 Performance Analysis of Variable Speed Pump Systems by Applying Bernoulli Equation |
author_sort |
Chien-Cheng Shih |
title |
Performance Analysis of Variable Speed Pump Systems by Applying Bernoulli Equation |
title_short |
Performance Analysis of Variable Speed Pump Systems by Applying Bernoulli Equation |
title_full |
Performance Analysis of Variable Speed Pump Systems by Applying Bernoulli Equation |
title_fullStr |
Performance Analysis of Variable Speed Pump Systems by Applying Bernoulli Equation |
title_full_unstemmed |
Performance Analysis of Variable Speed Pump Systems by Applying Bernoulli Equation |
title_sort |
performance analysis of variable speed pump systems by applying bernoulli equation |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/tn778e |
work_keys_str_mv |
AT chienchengshih performanceanalysisofvariablespeedpumpsystemsbyapplyingbernoulliequation AT shījiànchéng performanceanalysisofvariablespeedpumpsystemsbyapplyingbernoulliequation AT chienchengshih bǎinǔlìfāngchéngshìyīngyòngyúkōngdiàobiànpínbèngpǔpèiguǎnxìtǒngzhījìsuànyǔfēnxī AT shījiànchéng bǎinǔlìfāngchéngshìyīngyòngyúkōngdiàobiànpínbèngpǔpèiguǎnxìtǒngzhījìsuànyǔfēnxī |
_version_ |
1719118100488519680 |