The feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique

碩士 === 國立臺北科技大學 === 機電整合研究所 === 102 === The purpose of this study is to evaluate the feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique. According to the respiratory motion, the maximum range of organ displacement surrounding the lower...

Full description

Bibliographic Details
Main Authors: Shu-Kan Nieh, 聶叔衎
Other Authors: Ho-Chiao Chuang
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/2tn5h7
id ndltd-TW-102TIT05651117
record_format oai_dc
spelling ndltd-TW-102TIT056511172019-05-15T21:42:34Z http://ndltd.ncl.edu.tw/handle/2tn5h7 The feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique 超音波影像追蹤技術結合自動調控腫瘤定位系統之可行性評估 Shu-Kan Nieh 聶叔衎 碩士 國立臺北科技大學 機電整合研究所 102 The purpose of this study is to evaluate the feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique. According to the respiratory motion, the maximum range of organ displacement surrounding the lower lobe of lung is Superior-Inferior. The SI direction is issued with respiratory compensation in this study. However, there is respiratory signal delay in the system through generating ultrasound image, image processing, and signal transferring. For compensating the signal delay time, this study approaches the design of phase-lead compensator in the controller. There are two variants, variable “a” and gain of compensator, in the design of phase-lead compensator. When fixing the delay time for compensating, the variants will increase as the frequency of respiratory signal raise up. When fixing the frequency of respiratory signal, the variants will also increase as the delay time raise up. Before design of phase-lead compensator, we analyzed the system delay and concluded the respiratory delay time as 0.254+0.023 seconds in this study. For evaluating the feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique, there are 5 different frequencies of sine wave for simulating the respiratory signal as 0.5, 0.333, 0.25, 0.2, and 0.167 Hz. According to the varying frequency of sine wave, we tuned the variants of the compensator through the relationship of curve fitting. The conclusion is the rate of compensating the respiratory motion is stable and improved through phase-lead compensator. The rate of compensation promotes to 7.04-18.82% rather than without compensator, and the average of the compensation rate is approximately 97%. As a result, the auto tuning respiratory compensation system with ultrasonic image tracking technique is feasible. The advantages of the auto tuning respiratory compensation system as follows: 1. Non-invasive ultrasound sensor for active respiratory compensation. 2. Continuously radiotherapy treatment with this system. 3. Independent system suited for any treatment couch. 4. Operating easily for auto tuning respiratory compensation system. Ho-Chiao Chuang 莊賀喬 2014 學位論文 ; thesis 54 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 機電整合研究所 === 102 === The purpose of this study is to evaluate the feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique. According to the respiratory motion, the maximum range of organ displacement surrounding the lower lobe of lung is Superior-Inferior. The SI direction is issued with respiratory compensation in this study. However, there is respiratory signal delay in the system through generating ultrasound image, image processing, and signal transferring. For compensating the signal delay time, this study approaches the design of phase-lead compensator in the controller. There are two variants, variable “a” and gain of compensator, in the design of phase-lead compensator. When fixing the delay time for compensating, the variants will increase as the frequency of respiratory signal raise up. When fixing the frequency of respiratory signal, the variants will also increase as the delay time raise up. Before design of phase-lead compensator, we analyzed the system delay and concluded the respiratory delay time as 0.254+0.023 seconds in this study. For evaluating the feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique, there are 5 different frequencies of sine wave for simulating the respiratory signal as 0.5, 0.333, 0.25, 0.2, and 0.167 Hz. According to the varying frequency of sine wave, we tuned the variants of the compensator through the relationship of curve fitting. The conclusion is the rate of compensating the respiratory motion is stable and improved through phase-lead compensator. The rate of compensation promotes to 7.04-18.82% rather than without compensator, and the average of the compensation rate is approximately 97%. As a result, the auto tuning respiratory compensation system with ultrasonic image tracking technique is feasible. The advantages of the auto tuning respiratory compensation system as follows: 1. Non-invasive ultrasound sensor for active respiratory compensation. 2. Continuously radiotherapy treatment with this system. 3. Independent system suited for any treatment couch. 4. Operating easily for auto tuning respiratory compensation system.
author2 Ho-Chiao Chuang
author_facet Ho-Chiao Chuang
Shu-Kan Nieh
聶叔衎
author Shu-Kan Nieh
聶叔衎
spellingShingle Shu-Kan Nieh
聶叔衎
The feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique
author_sort Shu-Kan Nieh
title The feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique
title_short The feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique
title_full The feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique
title_fullStr The feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique
title_full_unstemmed The feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique
title_sort feasibility assessment of the auto tuning respiratory compensation system with ultrasonic image tracking technique
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/2tn5h7
work_keys_str_mv AT shukannieh thefeasibilityassessmentoftheautotuningrespiratorycompensationsystemwithultrasonicimagetrackingtechnique
AT nièshūkàn thefeasibilityassessmentoftheautotuningrespiratorycompensationsystemwithultrasonicimagetrackingtechnique
AT shukannieh chāoyīnbōyǐngxiàngzhuīzōngjìshùjiéhézìdòngdiàokòngzhǒngliúdìngwèixìtǒngzhīkěxíngxìngpínggū
AT nièshūkàn chāoyīnbōyǐngxiàngzhuīzōngjìshùjiéhézìdòngdiàokòngzhǒngliúdìngwèixìtǒngzhīkěxíngxìngpínggū
AT shukannieh feasibilityassessmentoftheautotuningrespiratorycompensationsystemwithultrasonicimagetrackingtechnique
AT nièshūkàn feasibilityassessmentoftheautotuningrespiratorycompensationsystemwithultrasonicimagetrackingtechnique
_version_ 1719118379196874752