Power-Factor-Corrected Rectifier with Input Current Zero-Crossing Distortion Improved

碩士 === 國立臺北科技大學 === 電機工程系所 === 102 === As generally acknowledged, energy saving has two methods. One is to upgrade the efficiency of the product; the other is to improve its power factor and reduce its harmonic distortion. In the power electronics product, the harmonic current affects the power fact...

Full description

Bibliographic Details
Main Authors: Chang-Hsun Chiang, 江昶勳
Other Authors: 胡國英
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/tnu7fc
id ndltd-TW-102TIT05442001
record_format oai_dc
spelling ndltd-TW-102TIT054420012019-06-27T05:12:32Z http://ndltd.ncl.edu.tw/handle/tnu7fc Power-Factor-Corrected Rectifier with Input Current Zero-Crossing Distortion Improved 具有改善輸入電流零交越失真之升壓型功率因數修正器 Chang-Hsun Chiang 江昶勳 碩士 國立臺北科技大學 電機工程系所 102 As generally acknowledged, energy saving has two methods. One is to upgrade the efficiency of the product; the other is to improve its power factor and reduce its harmonic distortion. In the power electronics product, the harmonic current affects the power factor and creates the undesired noise and the additional power loss. Therefore, the International Electrotechnical Commission (IEC) released IEC 6100-3-2 harmonics standards in 2001, and accordingly the harmonic limits were described in detail. In these standards, if the electronics product has the output power above 75W, the harmonic test is needed, which measures a single testing device so as to know how much the harmonics affect the power system. Although many active power factor correction topologies are presented to reduce the harmonic distortion to some extent, there still exists a common problem that the input current stops flowing and is distorted in the neighborhood of the zero input voltage. This is due to the forward voltages of the diodes in the bridge rectifier and the capacitor used to filter out high-frequency switching noises. In this study, based on the mention above, the voltage superposition is used without phase adjustment in the input current command and without enlarging the turn-on period of the switch in the vicinity of the zero input voltage, but only with a few components, so as to improve the zero-crossing distortion of the input current, thereby reducing the value of the total harmonic distortion. 胡國英 2013 學位論文 ; thesis 164 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 電機工程系所 === 102 === As generally acknowledged, energy saving has two methods. One is to upgrade the efficiency of the product; the other is to improve its power factor and reduce its harmonic distortion. In the power electronics product, the harmonic current affects the power factor and creates the undesired noise and the additional power loss. Therefore, the International Electrotechnical Commission (IEC) released IEC 6100-3-2 harmonics standards in 2001, and accordingly the harmonic limits were described in detail. In these standards, if the electronics product has the output power above 75W, the harmonic test is needed, which measures a single testing device so as to know how much the harmonics affect the power system. Although many active power factor correction topologies are presented to reduce the harmonic distortion to some extent, there still exists a common problem that the input current stops flowing and is distorted in the neighborhood of the zero input voltage. This is due to the forward voltages of the diodes in the bridge rectifier and the capacitor used to filter out high-frequency switching noises. In this study, based on the mention above, the voltage superposition is used without phase adjustment in the input current command and without enlarging the turn-on period of the switch in the vicinity of the zero input voltage, but only with a few components, so as to improve the zero-crossing distortion of the input current, thereby reducing the value of the total harmonic distortion.
author2 胡國英
author_facet 胡國英
Chang-Hsun Chiang
江昶勳
author Chang-Hsun Chiang
江昶勳
spellingShingle Chang-Hsun Chiang
江昶勳
Power-Factor-Corrected Rectifier with Input Current Zero-Crossing Distortion Improved
author_sort Chang-Hsun Chiang
title Power-Factor-Corrected Rectifier with Input Current Zero-Crossing Distortion Improved
title_short Power-Factor-Corrected Rectifier with Input Current Zero-Crossing Distortion Improved
title_full Power-Factor-Corrected Rectifier with Input Current Zero-Crossing Distortion Improved
title_fullStr Power-Factor-Corrected Rectifier with Input Current Zero-Crossing Distortion Improved
title_full_unstemmed Power-Factor-Corrected Rectifier with Input Current Zero-Crossing Distortion Improved
title_sort power-factor-corrected rectifier with input current zero-crossing distortion improved
publishDate 2013
url http://ndltd.ncl.edu.tw/handle/tnu7fc
work_keys_str_mv AT changhsunchiang powerfactorcorrectedrectifierwithinputcurrentzerocrossingdistortionimproved
AT jiāngchǎngxūn powerfactorcorrectedrectifierwithinputcurrentzerocrossingdistortionimproved
AT changhsunchiang jùyǒugǎishànshūrùdiànliúlíngjiāoyuèshīzhēnzhīshēngyāxínggōnglǜyīnshùxiūzhèngqì
AT jiāngchǎngxūn jùyǒugǎishànshūrùdiànliúlíngjiāoyuèshīzhēnzhīshēngyāxínggōnglǜyīnshùxiūzhèngqì
_version_ 1719210927784460288