The Study of D-lactate Fluorescence Biosensor Assay in Human Urine
碩士 === 國立臺北科技大學 === 光電工程系研究所 === 102 === The purpose of this study is to develop a method using solid phase extraction to remove the impurities in urine to decrease fluorescent noise, then add the nicotinamide adenine dinucleotide (NAD+) and D-lactate dehydrogenase (D-LDH) in urine. D-LDH will catal...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/dy2bax |
id |
ndltd-TW-102TIT05124030 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102TIT051240302019-05-15T21:42:32Z http://ndltd.ncl.edu.tw/handle/dy2bax The Study of D-lactate Fluorescence Biosensor Assay in Human Urine D-乳酸螢光生物感測器於人體尿液檢測方法之研究 Han-Yin Yu 余函穎 碩士 國立臺北科技大學 光電工程系研究所 102 The purpose of this study is to develop a method using solid phase extraction to remove the impurities in urine to decrease fluorescent noise, then add the nicotinamide adenine dinucleotide (NAD+) and D-lactate dehydrogenase (D-LDH) in urine. D-LDH will catalyze D-lactate and NAD+ to pyruvate and NADH, and then using biosensor that use the wavelength of 340 nm UV-LED to excite NADH and release the fluorescence of 490 nm to detect the concentration of D-lactate in urine. This method has good linearity (R2=0.9979) and calibration range from 1 μM to 125 μM. Accuracy is between 93.22~110.54% and precision is between 2.04 - 20.83%. The linearity, accuracy and precision of this method are complied with rules of analysis. And compared to Two-dimensional HPLC system (2-D HPLC system) this method can reduce the determination time from 90 minutes to 1 minute each sample. 陳建銘 2014 學位論文 ; thesis 45 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺北科技大學 === 光電工程系研究所 === 102 === The purpose of this study is to develop a method using solid phase extraction to remove the impurities in urine to decrease fluorescent noise, then add the nicotinamide adenine dinucleotide (NAD+) and D-lactate dehydrogenase (D-LDH) in urine. D-LDH will catalyze D-lactate and NAD+ to pyruvate and NADH, and then using biosensor that use the wavelength of 340 nm UV-LED to excite NADH and release the fluorescence of 490 nm to detect the concentration of D-lactate in urine. This method has good linearity (R2=0.9979) and calibration range from 1 μM to 125 μM. Accuracy is between 93.22~110.54% and precision is between 2.04 - 20.83%. The linearity, accuracy and precision of this method are complied with rules of analysis. And compared to Two-dimensional HPLC system (2-D HPLC system) this method can reduce the determination time from 90 minutes to 1 minute each sample.
|
author2 |
陳建銘 |
author_facet |
陳建銘 Han-Yin Yu 余函穎 |
author |
Han-Yin Yu 余函穎 |
spellingShingle |
Han-Yin Yu 余函穎 The Study of D-lactate Fluorescence Biosensor Assay in Human Urine |
author_sort |
Han-Yin Yu |
title |
The Study of D-lactate Fluorescence Biosensor Assay in Human Urine |
title_short |
The Study of D-lactate Fluorescence Biosensor Assay in Human Urine |
title_full |
The Study of D-lactate Fluorescence Biosensor Assay in Human Urine |
title_fullStr |
The Study of D-lactate Fluorescence Biosensor Assay in Human Urine |
title_full_unstemmed |
The Study of D-lactate Fluorescence Biosensor Assay in Human Urine |
title_sort |
study of d-lactate fluorescence biosensor assay in human urine |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/dy2bax |
work_keys_str_mv |
AT hanyinyu thestudyofdlactatefluorescencebiosensorassayinhumanurine AT yúhányǐng thestudyofdlactatefluorescencebiosensorassayinhumanurine AT hanyinyu drǔsuānyíngguāngshēngwùgǎncèqìyúréntǐniàoyèjiǎncèfāngfǎzhīyánjiū AT yúhányǐng drǔsuānyíngguāngshēngwùgǎncèqìyúréntǐniàoyèjiǎncèfāngfǎzhīyánjiū AT hanyinyu studyofdlactatefluorescencebiosensorassayinhumanurine AT yúhányǐng studyofdlactatefluorescencebiosensorassayinhumanurine |
_version_ |
1719117759491604480 |