Using Surface Plasmon Resonance Sensor for Detecting Bacterial Concentration
碩士 === 國立虎尾科技大學 === 光電與材料科技研究所 === 102 === Surface plasmon resonance sensing technique is a rapid, real-time, convenient operation without between calibrations can detect biomolecular interaction, is widely used in the field of medical, food, environment detection. Surface plasmon resonance sensor b...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/4es28a |
id |
ndltd-TW-102NYPI5124087 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102NYPI51240872019-09-22T03:41:16Z http://ndltd.ncl.edu.tw/handle/4es28a Using Surface Plasmon Resonance Sensor for Detecting Bacterial Concentration 利用表面電漿共振感測器檢測細菌濃度 Bing-Yu Peng 彭秉煜 碩士 國立虎尾科技大學 光電與材料科技研究所 102 Surface plasmon resonance sensing technique is a rapid, real-time, convenient operation without between calibrations can detect biomolecular interaction, is widely used in the field of medical, food, environment detection. Surface plasmon resonance sensor by refraction detection of metal film on the surface of a rate change so that the incident light resonance angle change to analyze the interaction between biological molecules. In this study, using surface plasmon resonance sensing technology to carry out bacterial concentration detection, at a fixed wavelength of the incident light detection of different concentration, the detecting resonance angle can change that change the object to be measured, and establish the relationship between the surface plasmon resonance angle and the bacterial concentration. Also with the determination of colonies number application method, spread plate, the different concentration with sterile water for dilution, colonies forming the dilution of the number, and to calculate the concentration of the bacteria from the number of colonies. Finally, based on the relation between the surface plasmon resonance angle and the number of colonies for rapid detection of bacterial concentration. Using of surface plasmon resonance sensor for rapid detection of bacterial concentration to replace the traditional detection method time-consuming spread plate method in the determination of the number of colonies in future. 蔡裕勝 劉育松 2014 學位論文 ; thesis 59 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立虎尾科技大學 === 光電與材料科技研究所 === 102 === Surface plasmon resonance sensing technique is a rapid, real-time, convenient operation without between calibrations can detect biomolecular interaction, is widely used in the field of medical, food, environment detection. Surface plasmon resonance sensor by refraction detection of metal film on the surface of a rate change so that the incident light resonance angle change to analyze the interaction between biological molecules.
In this study, using surface plasmon resonance sensing technology to carry out bacterial concentration detection, at a fixed wavelength of the incident light detection of different concentration, the detecting resonance angle can change that change the object to be measured, and establish the relationship between the surface plasmon resonance angle and the bacterial concentration. Also with the determination of colonies number application method, spread plate, the different concentration with sterile water for dilution, colonies forming the dilution of the number, and to calculate the concentration of the bacteria from the number of colonies.
Finally, based on the relation between the surface plasmon resonance angle and the number of colonies for rapid detection of bacterial concentration. Using of surface plasmon resonance sensor for rapid detection of bacterial concentration to replace the traditional detection method time-consuming spread plate method in the determination of the number of colonies in future.
|
author2 |
蔡裕勝 |
author_facet |
蔡裕勝 Bing-Yu Peng 彭秉煜 |
author |
Bing-Yu Peng 彭秉煜 |
spellingShingle |
Bing-Yu Peng 彭秉煜 Using Surface Plasmon Resonance Sensor for Detecting Bacterial Concentration |
author_sort |
Bing-Yu Peng |
title |
Using Surface Plasmon Resonance Sensor for Detecting Bacterial Concentration |
title_short |
Using Surface Plasmon Resonance Sensor for Detecting Bacterial Concentration |
title_full |
Using Surface Plasmon Resonance Sensor for Detecting Bacterial Concentration |
title_fullStr |
Using Surface Plasmon Resonance Sensor for Detecting Bacterial Concentration |
title_full_unstemmed |
Using Surface Plasmon Resonance Sensor for Detecting Bacterial Concentration |
title_sort |
using surface plasmon resonance sensor for detecting bacterial concentration |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/4es28a |
work_keys_str_mv |
AT bingyupeng usingsurfaceplasmonresonancesensorfordetectingbacterialconcentration AT péngbǐngyù usingsurfaceplasmonresonancesensorfordetectingbacterialconcentration AT bingyupeng lìyòngbiǎomiàndiànjiānggòngzhèngǎncèqìjiǎncèxìjūnnóngdù AT péngbǐngyù lìyòngbiǎomiàndiànjiānggòngzhèngǎncèqìjiǎncèxìjūnnóngdù |
_version_ |
1719254998170206208 |