Study on the Influencing Factors of Reinforcement Corrosion Measurements in Concrete

碩士 === 國立臺灣科技大學 === 營建工程系 === 102 === This study explores the influencing factors, reliability, and methods to increase the accuracy in reinforment corrosion measurements. The results are expected to be applicable onsite, thereby contributing to draft for a new standard and evaluate the lifecycles i...

Full description

Bibliographic Details
Main Authors: Ching-Hsien Wu, 吳靖賢
Other Authors: Chun-tao Chen
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/77736665675189041713
id ndltd-TW-102NTUS5512115
record_format oai_dc
spelling ndltd-TW-102NTUS55121152016-03-09T04:30:59Z http://ndltd.ncl.edu.tw/handle/77736665675189041713 Study on the Influencing Factors of Reinforcement Corrosion Measurements in Concrete 影響混凝土中鋼筋腐蝕量測之因子探討 Ching-Hsien Wu 吳靖賢 碩士 國立臺灣科技大學 營建工程系 102 This study explores the influencing factors, reliability, and methods to increase the accuracy in reinforment corrosion measurements. The results are expected to be applicable onsite, thereby contributing to draft for a new standard and evaluate the lifecycles in existing or new buildings. During the tests, the specimens were immersed in 3.5% salt water and charged for accelerated coccorion. The corrosion currents were measured daily using galvanostatic technique, linear polarization and impendences. The corrosion rates and the amount of corrosion were then estimated and used to be compared with the weight loss. Results showed that the calculated weight loss is linearly proportional to the weight loss in mortar specimens with w/c of 0.4, 0.5, and 0.6, and cover thickness of 3 cm or 6 cm. The weight loss can be estimated by multiplying the calculated weight losses by 25, 50, 250, or 1000, respectively. In concrete specimens, such multiplying factor is only 5. In addition, the measuring values of the corrosion currents were reduced by 20% as the moisture content of the specimens were reduced by 5%. The measurements at the location where the dow bars overlapped were unstable and the dow bars had more severe corrosion than the main bars. Adequate polarization can be archieved by using impulse current of 100 μA and impulse time of 10 s, and stable measurements were obtained by using an overpotential of ±10 mV and duration of 30 s. On the other hand, the measurements were not taken in specimens with tiles ontop. Therefore, in future applications, the tiles must be removed and the cover properties must be considered prior to the corrosion measurements. Chun-tao Chen 陳君弢 2014 學位論文 ; thesis 199 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 營建工程系 === 102 === This study explores the influencing factors, reliability, and methods to increase the accuracy in reinforment corrosion measurements. The results are expected to be applicable onsite, thereby contributing to draft for a new standard and evaluate the lifecycles in existing or new buildings. During the tests, the specimens were immersed in 3.5% salt water and charged for accelerated coccorion. The corrosion currents were measured daily using galvanostatic technique, linear polarization and impendences. The corrosion rates and the amount of corrosion were then estimated and used to be compared with the weight loss. Results showed that the calculated weight loss is linearly proportional to the weight loss in mortar specimens with w/c of 0.4, 0.5, and 0.6, and cover thickness of 3 cm or 6 cm. The weight loss can be estimated by multiplying the calculated weight losses by 25, 50, 250, or 1000, respectively. In concrete specimens, such multiplying factor is only 5. In addition, the measuring values of the corrosion currents were reduced by 20% as the moisture content of the specimens were reduced by 5%. The measurements at the location where the dow bars overlapped were unstable and the dow bars had more severe corrosion than the main bars. Adequate polarization can be archieved by using impulse current of 100 μA and impulse time of 10 s, and stable measurements were obtained by using an overpotential of ±10 mV and duration of 30 s. On the other hand, the measurements were not taken in specimens with tiles ontop. Therefore, in future applications, the tiles must be removed and the cover properties must be considered prior to the corrosion measurements.
author2 Chun-tao Chen
author_facet Chun-tao Chen
Ching-Hsien Wu
吳靖賢
author Ching-Hsien Wu
吳靖賢
spellingShingle Ching-Hsien Wu
吳靖賢
Study on the Influencing Factors of Reinforcement Corrosion Measurements in Concrete
author_sort Ching-Hsien Wu
title Study on the Influencing Factors of Reinforcement Corrosion Measurements in Concrete
title_short Study on the Influencing Factors of Reinforcement Corrosion Measurements in Concrete
title_full Study on the Influencing Factors of Reinforcement Corrosion Measurements in Concrete
title_fullStr Study on the Influencing Factors of Reinforcement Corrosion Measurements in Concrete
title_full_unstemmed Study on the Influencing Factors of Reinforcement Corrosion Measurements in Concrete
title_sort study on the influencing factors of reinforcement corrosion measurements in concrete
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/77736665675189041713
work_keys_str_mv AT chinghsienwu studyontheinfluencingfactorsofreinforcementcorrosionmeasurementsinconcrete
AT wújìngxián studyontheinfluencingfactorsofreinforcementcorrosionmeasurementsinconcrete
AT chinghsienwu yǐngxiǎnghùnníngtǔzhōnggāngjīnfǔshíliàngcèzhīyīnzitàntǎo
AT wújìngxián yǐngxiǎnghùnníngtǔzhōnggāngjīnfǔshíliàngcèzhīyīnzitàntǎo
_version_ 1718202476872597504