Development of non-invasive system for measuring compartment pressure

碩士 === 國立臺灣科技大學 === 機械工程系 === 102 === Compartment syndrome (CS) occurs when the tissue pressure within a closed muscle compartment exceeds the perfusion pressure and results in muscle and nerve ischemia. Common causes of compartment syndrome include long bone fractures, high-energy trauma, puncture...

Full description

Bibliographic Details
Main Authors: Liang-chun Chen, 陳亮均
Other Authors: none
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/60259122391507213632
id ndltd-TW-102NTUS5489111
record_format oai_dc
spelling ndltd-TW-102NTUS54891112016-09-25T04:04:34Z http://ndltd.ncl.edu.tw/handle/60259122391507213632 Development of non-invasive system for measuring compartment pressure 非侵入式腔室壓力量測系統開發 Liang-chun Chen 陳亮均 碩士 國立臺灣科技大學 機械工程系 102 Compartment syndrome (CS) occurs when the tissue pressure within a closed muscle compartment exceeds the perfusion pressure and results in muscle and nerve ischemia. Common causes of compartment syndrome include long bone fractures, high-energy trauma, puncture wounds, venous injury, crush injuries. If the pressure continues to rise for several hours, then tissue will die and it may cause irreversible damage. Currently, a needle is inserted into the area of suspected compartment syndrome while an attached pressure monitor records the pressure to diagnose the compartment syndrome. The invasive method has some problems: 1. neurovascular injuries and wound infections. 2. it has to be used in operaration room. This study developed a non-invasive compartment pressure measuring system which is with flexble pressure sensors, and experiments were performed with this system on a lower leg CS simulation model. Compartment pressure and on skin pressure according to placed sensor positions were simulated by finite element analysis software ANSYS Workbench 14.5. In addition, the material properties of nonlinear materials, soft tissue and muscle, were applied in the theoretical simulation to approach the real lower leg compartment syndrome case, to study tissue and muscle deformation and pressure distribution. Finally, the results of the experiment and simulation were discussed in detail. none 張復瑜 2014 學位論文 ; thesis 108 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣科技大學 === 機械工程系 === 102 === Compartment syndrome (CS) occurs when the tissue pressure within a closed muscle compartment exceeds the perfusion pressure and results in muscle and nerve ischemia. Common causes of compartment syndrome include long bone fractures, high-energy trauma, puncture wounds, venous injury, crush injuries. If the pressure continues to rise for several hours, then tissue will die and it may cause irreversible damage. Currently, a needle is inserted into the area of suspected compartment syndrome while an attached pressure monitor records the pressure to diagnose the compartment syndrome. The invasive method has some problems: 1. neurovascular injuries and wound infections. 2. it has to be used in operaration room. This study developed a non-invasive compartment pressure measuring system which is with flexble pressure sensors, and experiments were performed with this system on a lower leg CS simulation model. Compartment pressure and on skin pressure according to placed sensor positions were simulated by finite element analysis software ANSYS Workbench 14.5. In addition, the material properties of nonlinear materials, soft tissue and muscle, were applied in the theoretical simulation to approach the real lower leg compartment syndrome case, to study tissue and muscle deformation and pressure distribution. Finally, the results of the experiment and simulation were discussed in detail.
author2 none
author_facet none
Liang-chun Chen
陳亮均
author Liang-chun Chen
陳亮均
spellingShingle Liang-chun Chen
陳亮均
Development of non-invasive system for measuring compartment pressure
author_sort Liang-chun Chen
title Development of non-invasive system for measuring compartment pressure
title_short Development of non-invasive system for measuring compartment pressure
title_full Development of non-invasive system for measuring compartment pressure
title_fullStr Development of non-invasive system for measuring compartment pressure
title_full_unstemmed Development of non-invasive system for measuring compartment pressure
title_sort development of non-invasive system for measuring compartment pressure
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/60259122391507213632
work_keys_str_mv AT liangchunchen developmentofnoninvasivesystemformeasuringcompartmentpressure
AT chénliàngjūn developmentofnoninvasivesystemformeasuringcompartmentpressure
AT liangchunchen fēiqīnrùshìqiāngshìyālìliàngcèxìtǒngkāifā
AT chénliàngjūn fēiqīnrùshìqiāngshìyālìliàngcèxìtǒngkāifā
_version_ 1718384885658288128