The initial design and setup of camera system for ship cavitation observation
碩士 === 國立臺灣海洋大學 === 系統工程暨造船學系 === 102 === The goal of this research work is to design and setup the ship cavitation observation camera system and its supporting rotating stages for the camera and light source. The ability to remote control and adjust the snap angle of the camera is very important f...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/zykjqm |
id |
ndltd-TW-102NTOU5345011 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102NTOU53450112019-05-15T21:51:45Z http://ndltd.ncl.edu.tw/handle/zykjqm The initial design and setup of camera system for ship cavitation observation 船舶空蝕現象觀測攝影系統規劃設計與架設 Huang, Yi-Kai 黃詣凱 碩士 國立臺灣海洋大學 系統工程暨造船學系 102 The goal of this research work is to design and setup the ship cavitation observation camera system and its supporting rotating stages for the camera and light source. The ability to remote control and adjust the snap angle of the camera is very important for the ship cavitation observation and has been achieved. The requirements of the lamp and the camera have been defined and then different light collecting cover for the lamp have been designed and produced. To verify the effect of the light collecting cover, some tests has been done and the qualities of the images acquired with different camera snap parameters have been confirmed. The rotating stages for the lamp and camera have been designed according to the specifications. The camera rotating mechanism is commercial, and the position of the limit switches has been shifted to confine the rotation angle to the need. The rotating stage for the light source has been completed by adapting two gear motors and designing rotation mechanical components and the simple control circuit. The limit switches was also used to prevent the damage caused by collision. The two rotating stages have been confirmed its feasibility. A series images were captured by the camera with different observation angles of the optical axis by remote controlling of the stage. The rotating angle of the camera has been calculated and it was about ±30 degree. The same range of the rotating angle could be achieved by the limit switches of different position. It showed that both the modified and the self-design rotating stages and the whole system satisfy the remote control requirements of ship cavitation observation 李舒昇 2014 學位論文 ; thesis 43 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立臺灣海洋大學 === 系統工程暨造船學系 === 102 === The goal of this research work is to design and setup the ship cavitation observation camera system and its supporting rotating stages for the camera and light source. The ability to remote control and adjust the snap angle of the camera is very important for the ship cavitation observation and has been achieved. The requirements of the lamp and the camera have been defined and then different light collecting cover for the lamp have been designed and produced. To verify the effect of the light collecting cover, some tests has been done and the qualities of the images acquired with different camera snap parameters have been confirmed. The rotating stages for the lamp and camera have been designed according to the specifications. The camera rotating mechanism is commercial, and the position of the limit switches has been shifted to confine the rotation angle to the need. The rotating stage for the light source has been completed by adapting two gear motors and designing rotation mechanical components and the simple control circuit. The limit switches was also used to prevent the damage caused by collision.
The two rotating stages have been confirmed its feasibility. A series images were captured by the camera with different observation angles of the optical axis by remote controlling of the stage. The rotating angle of the camera has been calculated and it was about ±30 degree. The same range of the rotating angle could be achieved by the limit switches of different position. It showed that both the modified and the self-design rotating stages and the whole system satisfy the remote control requirements of ship cavitation observation
|
author2 |
李舒昇 |
author_facet |
李舒昇 Huang, Yi-Kai 黃詣凱 |
author |
Huang, Yi-Kai 黃詣凱 |
spellingShingle |
Huang, Yi-Kai 黃詣凱 The initial design and setup of camera system for ship cavitation observation |
author_sort |
Huang, Yi-Kai |
title |
The initial design and setup of camera system for ship cavitation observation |
title_short |
The initial design and setup of camera system for ship cavitation observation |
title_full |
The initial design and setup of camera system for ship cavitation observation |
title_fullStr |
The initial design and setup of camera system for ship cavitation observation |
title_full_unstemmed |
The initial design and setup of camera system for ship cavitation observation |
title_sort |
initial design and setup of camera system for ship cavitation observation |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/zykjqm |
work_keys_str_mv |
AT huangyikai theinitialdesignandsetupofcamerasystemforshipcavitationobservation AT huángyìkǎi theinitialdesignandsetupofcamerasystemforshipcavitationobservation AT huangyikai chuánbókōngshíxiànxiàngguāncèshèyǐngxìtǒngguīhuàshèjìyǔjiàshè AT huángyìkǎi chuánbókōngshíxiànxiàngguāncèshèyǐngxìtǒngguīhuàshèjìyǔjiàshè AT huangyikai initialdesignandsetupofcamerasystemforshipcavitationobservation AT huángyìkǎi initialdesignandsetupofcamerasystemforshipcavitationobservation |
_version_ |
1719120672428392448 |