An Improved Method for Attenuation Correction in Single Photon Emission Computed Tomography

碩士 === 國立清華大學 === 生醫工程與環境科學系 === 102 === Single photon emission computed tomography (SPECT), an important technique in nuclear medicine, can collect the emitted photons of the radionuclide and reconstruct the images of radionuclide distribution inside body through computer calculation. However, atte...

Full description

Bibliographic Details
Main Author: 王信超
Other Authors: 莊克士
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/96473205680105946061
id ndltd-TW-102NTHU5810038
record_format oai_dc
spelling ndltd-TW-102NTHU58100382016-03-09T04:31:13Z http://ndltd.ncl.edu.tw/handle/96473205680105946061 An Improved Method for Attenuation Correction in Single Photon Emission Computed Tomography 單光子射出電腦斷層攝影之改良式衰減校正法 王信超 碩士 國立清華大學 生醫工程與環境科學系 102 Single photon emission computed tomography (SPECT), an important technique in nuclear medicine, can collect the emitted photons of the radionuclide and reconstruct the images of radionuclide distribution inside body through computer calculation. However, attenuation and scatter effect occurs when photon passing through the body and will reduce quantitative accuracy of measured radioactivity concentration. In order to achieve the quantitative accuracy, it is necessary to compensate the photon attenuation in the object. The most used attenuation correction method in SPECT is Chang’s method. In this study, we proposed a method called Improved Attenuation Correction (IAC) method. The IAC method estimates the ACF map by calculating the equivalent linear attenuation coefficient based on the attenuation map and the activity map. The attenuation map can be calculated from CT images, while the activity map can be assumed uniform in the initial step. After attenuation correction using the calculated ACF map of IAC, the image can be reconstructed by filter back-projection algorithm and the activity map for next iteration. The iteration stops when the difference between the reconstructed images of two successive iterations is smaller than a predefined criterion. The performance was evaluated by using Monte Carlo simulations of two digital phantoms (brain phantom and thorax phantom). The simulated results demonstrated that the proposed method achieved better image quality and quantitative accuracy than Chang’s method. We concluded that the proposed attenuation correction method could effectively restore the activity concentration and is potential for clinical uses. 莊克士 2014 學位論文 ; thesis 82 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立清華大學 === 生醫工程與環境科學系 === 102 === Single photon emission computed tomography (SPECT), an important technique in nuclear medicine, can collect the emitted photons of the radionuclide and reconstruct the images of radionuclide distribution inside body through computer calculation. However, attenuation and scatter effect occurs when photon passing through the body and will reduce quantitative accuracy of measured radioactivity concentration. In order to achieve the quantitative accuracy, it is necessary to compensate the photon attenuation in the object. The most used attenuation correction method in SPECT is Chang’s method. In this study, we proposed a method called Improved Attenuation Correction (IAC) method. The IAC method estimates the ACF map by calculating the equivalent linear attenuation coefficient based on the attenuation map and the activity map. The attenuation map can be calculated from CT images, while the activity map can be assumed uniform in the initial step. After attenuation correction using the calculated ACF map of IAC, the image can be reconstructed by filter back-projection algorithm and the activity map for next iteration. The iteration stops when the difference between the reconstructed images of two successive iterations is smaller than a predefined criterion. The performance was evaluated by using Monte Carlo simulations of two digital phantoms (brain phantom and thorax phantom). The simulated results demonstrated that the proposed method achieved better image quality and quantitative accuracy than Chang’s method. We concluded that the proposed attenuation correction method could effectively restore the activity concentration and is potential for clinical uses.
author2 莊克士
author_facet 莊克士
王信超
author 王信超
spellingShingle 王信超
An Improved Method for Attenuation Correction in Single Photon Emission Computed Tomography
author_sort 王信超
title An Improved Method for Attenuation Correction in Single Photon Emission Computed Tomography
title_short An Improved Method for Attenuation Correction in Single Photon Emission Computed Tomography
title_full An Improved Method for Attenuation Correction in Single Photon Emission Computed Tomography
title_fullStr An Improved Method for Attenuation Correction in Single Photon Emission Computed Tomography
title_full_unstemmed An Improved Method for Attenuation Correction in Single Photon Emission Computed Tomography
title_sort improved method for attenuation correction in single photon emission computed tomography
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/96473205680105946061
work_keys_str_mv AT wángxìnchāo animprovedmethodforattenuationcorrectioninsinglephotonemissioncomputedtomography
AT wángxìnchāo dānguāngzishèchūdiànnǎoduàncéngshèyǐngzhīgǎiliángshìshuāijiǎnxiàozhèngfǎ
AT wángxìnchāo improvedmethodforattenuationcorrectioninsinglephotonemissioncomputedtomography
_version_ 1718202297081659392