Determination of Arsenic Species in Fishes and Cobalt Species in Functional drinks &; Nutritive supplements Using High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry

碩士 === 國立中山大學 === 化學系研究所 === 102 === The purpose of the first study was to assess the arsenic species content in the fishes and hoped for using the principal component analysis (PCA) to discriminate the different fishes. The determination of arsenic species in fishes was performed using ion exchange...

Full description

Bibliographic Details
Main Authors: Che-wei Wu, 吳哲維
Other Authors: Shiuh-Jen Jiang
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/cf2k52
id ndltd-TW-102NSYS5065072
record_format oai_dc
spelling ndltd-TW-102NSYS50650722018-05-09T05:10:29Z http://ndltd.ncl.edu.tw/handle/cf2k52 Determination of Arsenic Species in Fishes and Cobalt Species in Functional drinks &; Nutritive supplements Using High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry 液相層析結合感應耦合電漿質譜儀於魚肉中砷物種及功能性飲料和營養補給品中鈷物種之分析應用 Che-wei Wu 吳哲維 碩士 國立中山大學 化學系研究所 102 The purpose of the first study was to assess the arsenic species content in the fishes and hoped for using the principal component analysis (PCA) to discriminate the different fishes. The determination of arsenic species in fishes was performed using ion exchange chromatography on a PRP X-100 column with inductively coupled plasma mass spectrometry detection after two step microwave assisted extraction. The arsenic species studied were arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB) and arsenocholine (AsC). Chromatographic separation of all the species was achieved in &;lt;8 min in gradient elution mode using (NH4)2CO3 and methanol at pH 8.5. The six extraction methods on arsenic extraction recoveries was evaluated in real sample. The recovery of arsenic species with the two step extraction ( MeOH / Mobile phase A and 1% nitric acid) in real samples were up to 94%. The limits of detection were in the range of 0.005−0.011 μg L−1 for various arsenic species based on peak height. The purpose of the second study was to develop a method for separating the cobalt species and assess the species content in the functional drinks, nutritive supplements and seaweeds. The determination of cobalt species in functional drinks and nutritive supplements was performed using reversed phase chromatography on C8 micropore column with inductively coupled plasma mass spectrometry detection after microwave assisted extraction. The cobalt species studied were cobalt [Co(II)], hydroxocobalamin (OH-Cbl), cyanocobalamin (CN-Cbl), 5’-deoxyladenosylcobalamin (Ado-Cbl) and methylcobalamin (Me-Cbl). The species were separated by using NH4OAc and acetonitrile at pH 4.0 as elution solution, operated in a stepwise mode, yielded well resolved chromatograms of all the species within 15 min. The five extraction methods on cobalt extraction recoveries was evaluated in real sample. The recovery of arsenic species with the two step extraction (0.5% nitric acid) in real samples were up to 91%. The detection limits of the procedure were 0.007−0.031 μg L−1 for various cobalt species based on peak height. Shiuh-Jen Jiang 江旭禎 2014 學位論文 ; thesis 133 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中山大學 === 化學系研究所 === 102 === The purpose of the first study was to assess the arsenic species content in the fishes and hoped for using the principal component analysis (PCA) to discriminate the different fishes. The determination of arsenic species in fishes was performed using ion exchange chromatography on a PRP X-100 column with inductively coupled plasma mass spectrometry detection after two step microwave assisted extraction. The arsenic species studied were arsenite [As(III)], arsenate [As(V)], monomethylarsonic acid (MMA), dimethylarsinic acid (DMA), arsenobetaine (AsB) and arsenocholine (AsC). Chromatographic separation of all the species was achieved in &;lt;8 min in gradient elution mode using (NH4)2CO3 and methanol at pH 8.5. The six extraction methods on arsenic extraction recoveries was evaluated in real sample. The recovery of arsenic species with the two step extraction ( MeOH / Mobile phase A and 1% nitric acid) in real samples were up to 94%. The limits of detection were in the range of 0.005−0.011 μg L−1 for various arsenic species based on peak height. The purpose of the second study was to develop a method for separating the cobalt species and assess the species content in the functional drinks, nutritive supplements and seaweeds. The determination of cobalt species in functional drinks and nutritive supplements was performed using reversed phase chromatography on C8 micropore column with inductively coupled plasma mass spectrometry detection after microwave assisted extraction. The cobalt species studied were cobalt [Co(II)], hydroxocobalamin (OH-Cbl), cyanocobalamin (CN-Cbl), 5’-deoxyladenosylcobalamin (Ado-Cbl) and methylcobalamin (Me-Cbl). The species were separated by using NH4OAc and acetonitrile at pH 4.0 as elution solution, operated in a stepwise mode, yielded well resolved chromatograms of all the species within 15 min. The five extraction methods on cobalt extraction recoveries was evaluated in real sample. The recovery of arsenic species with the two step extraction (0.5% nitric acid) in real samples were up to 91%. The detection limits of the procedure were 0.007−0.031 μg L−1 for various cobalt species based on peak height.
author2 Shiuh-Jen Jiang
author_facet Shiuh-Jen Jiang
Che-wei Wu
吳哲維
author Che-wei Wu
吳哲維
spellingShingle Che-wei Wu
吳哲維
Determination of Arsenic Species in Fishes and Cobalt Species in Functional drinks &; Nutritive supplements Using High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry
author_sort Che-wei Wu
title Determination of Arsenic Species in Fishes and Cobalt Species in Functional drinks &; Nutritive supplements Using High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry
title_short Determination of Arsenic Species in Fishes and Cobalt Species in Functional drinks &; Nutritive supplements Using High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry
title_full Determination of Arsenic Species in Fishes and Cobalt Species in Functional drinks &; Nutritive supplements Using High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry
title_fullStr Determination of Arsenic Species in Fishes and Cobalt Species in Functional drinks &; Nutritive supplements Using High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry
title_full_unstemmed Determination of Arsenic Species in Fishes and Cobalt Species in Functional drinks &; Nutritive supplements Using High Performance Liquid Chromatography Inductively Coupled Plasma Mass Spectrometry
title_sort determination of arsenic species in fishes and cobalt species in functional drinks &; nutritive supplements using high performance liquid chromatography inductively coupled plasma mass spectrometry
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/cf2k52
work_keys_str_mv AT cheweiwu determinationofarsenicspeciesinfishesandcobaltspeciesinfunctionaldrinksnutritivesupplementsusinghighperformanceliquidchromatographyinductivelycoupledplasmamassspectrometry
AT wúzhéwéi determinationofarsenicspeciesinfishesandcobaltspeciesinfunctionaldrinksnutritivesupplementsusinghighperformanceliquidchromatographyinductivelycoupledplasmamassspectrometry
AT cheweiwu yèxiāngcéngxījiéhégǎnyīngǒuhédiànjiāngzhìpǔyíyúyúròuzhōngshēnwùzhǒngjígōngnéngxìngyǐnliàohéyíngyǎngbǔgěipǐnzhōnggǔwùzhǒngzhīfēnxīyīngyòng
AT wúzhéwéi yèxiāngcéngxījiéhégǎnyīngǒuhédiànjiāngzhìpǔyíyúyúròuzhōngshēnwùzhǒngjígōngnéngxìngyǐnliàohéyíngyǎngbǔgěipǐnzhōnggǔwùzhǒngzhīfēnxīyīngyòng
_version_ 1718635079820902400