Investigation of the Emission Factors for Dioxin from Stationary Sources
碩士 === 國立高雄第一科技大學 === 環境與安全衛生工程研究所 === 102 === Estimation of expellant amount is fundamental to air pollution control. Emission factor establishment contributes to measuring expelling pollutants. Nowadays, domestic studies focus on the research of incinerators and agglomerating furnace on the emissi...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/85110505894372689450 |
id |
ndltd-TW-102NKIT5519031 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102NKIT55190312016-07-03T04:13:34Z http://ndltd.ncl.edu.tw/handle/85110505894372689450 Investigation of the Emission Factors for Dioxin from Stationary Sources 固定源排放管道戴奧辛排放係數調查研究 Hsueh-Chang Hsieh 謝學昌 碩士 國立高雄第一科技大學 環境與安全衛生工程研究所 102 Estimation of expellant amount is fundamental to air pollution control. Emission factor establishment contributes to measuring expelling pollutants. Nowadays, domestic studies focus on the research of incinerators and agglomerating furnace on the emission of Dioxin and its correlation. Most of the research is based on foreign thesis and AP-42, which refers to a low credibility in domestic research. This study aims to conduct the research of Dioxin discharged by coal burning, secondary smelting and alloying of alumni, and cement kiln procedure. Relevant experiments were carried out according to the items announced by Environmental Protection Administration (EPA). This study aims to analyze the emission factors from fixed pollutants, such as coal burning, secondary smelting and alloying of alumni, and cement kiln procedure. The method is based on PCDD/Fs analysis on NIEA A810.13B announced by EPA. The emission factor of coal burning is 1326.71-1349.45 ng I-TEQ/Ton, the secondary smelting and alloying of alumni emission factor is 24.84-549.62 ng I-TEQ/Ton. And the emission factor of cement kiln procedure is 95.4-102.66 ng I-TEQ/Ton. The statistics shows that the emission factor is lower than that provided by American EPA, which indicates that American EPA emission factor shows less undefined dealing efficiency in control equipment. Jim Juimin Lin 林銳敏 2014 學位論文 ; thesis 83 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立高雄第一科技大學 === 環境與安全衛生工程研究所 === 102 === Estimation of expellant amount is fundamental to air pollution control. Emission factor establishment contributes to measuring expelling pollutants. Nowadays, domestic studies focus on the research of incinerators and agglomerating furnace on the emission of Dioxin and its correlation. Most of the research is based on foreign thesis and AP-42, which refers to a low credibility in domestic research. This study aims to conduct the research of Dioxin discharged by coal burning, secondary smelting and alloying of alumni, and cement kiln procedure. Relevant experiments were carried out according to the items announced by Environmental Protection Administration (EPA).
This study aims to analyze the emission factors from fixed pollutants, such as coal burning, secondary smelting and alloying of alumni, and cement kiln procedure. The method is based on PCDD/Fs analysis on NIEA A810.13B announced by EPA. The emission factor of coal burning is 1326.71-1349.45 ng I-TEQ/Ton, the secondary smelting and alloying of alumni emission factor is 24.84-549.62 ng I-TEQ/Ton. And the emission factor of cement kiln procedure is 95.4-102.66 ng I-TEQ/Ton. The statistics shows that the emission factor is lower than that provided by American EPA, which indicates that American EPA emission factor shows less undefined dealing efficiency in control equipment.
|
author2 |
Jim Juimin Lin |
author_facet |
Jim Juimin Lin Hsueh-Chang Hsieh 謝學昌 |
author |
Hsueh-Chang Hsieh 謝學昌 |
spellingShingle |
Hsueh-Chang Hsieh 謝學昌 Investigation of the Emission Factors for Dioxin from Stationary Sources |
author_sort |
Hsueh-Chang Hsieh |
title |
Investigation of the Emission Factors for Dioxin from Stationary Sources |
title_short |
Investigation of the Emission Factors for Dioxin from Stationary Sources |
title_full |
Investigation of the Emission Factors for Dioxin from Stationary Sources |
title_fullStr |
Investigation of the Emission Factors for Dioxin from Stationary Sources |
title_full_unstemmed |
Investigation of the Emission Factors for Dioxin from Stationary Sources |
title_sort |
investigation of the emission factors for dioxin from stationary sources |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/85110505894372689450 |
work_keys_str_mv |
AT hsuehchanghsieh investigationoftheemissionfactorsfordioxinfromstationarysources AT xièxuéchāng investigationoftheemissionfactorsfordioxinfromstationarysources AT hsuehchanghsieh gùdìngyuánpáifàngguǎndàodàiàoxīnpáifàngxìshùdiàocháyánjiū AT xièxuéchāng gùdìngyuánpáifàngguǎndàodàiàoxīnpáifàngxìshùdiàocháyánjiū |
_version_ |
1718333934172897280 |