Lattice-parameter-controlled sensitivities of imprinted photonic crystals for BPA detection

碩士 === 國立交通大學 === 環境工程系所 === 102 === In this study, a high sensitive and quick responsive ZrO2 imprinted photonic crystal (IPC) for detection of BPA was developed. The diffraction wavelength shift, resulting from the changes in the refractive index(n) of the IPC after rebinding of BPA, is used for t...

Full description

Bibliographic Details
Main Authors: Fang, Chih-Hsiang, 方峙翔
Other Authors: Chang, Sue-Min
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/57743510136412379233
id ndltd-TW-102NCTU5515005
record_format oai_dc
spelling ndltd-TW-102NCTU55150052016-07-02T04:20:29Z http://ndltd.ncl.edu.tw/handle/57743510136412379233 Lattice-parameter-controlled sensitivities of imprinted photonic crystals for BPA detection 晶格參數調控拓印光子晶體感測雙酚A之靈敏度 Fang, Chih-Hsiang 方峙翔 碩士 國立交通大學 環境工程系所 102 In this study, a high sensitive and quick responsive ZrO2 imprinted photonic crystal (IPC) for detection of BPA was developed. The diffraction wavelength shift, resulting from the changes in the refractive index(n) of the IPC after rebinding of BPA, is used for the quantification of the target compound. Polystyrene(PS) microspheres with the sizes in the range of 235-285 nm as the template for inverse opal photonic crystals were prepared using emulsion free and emulsion polymerization method. They self-assembled into opal structure through a heat-assisted method at 50C. Imprinted precursor solution, containing phenyltrimethoxysilane (PTMOS) as the functional monomer and zirconium propoxide (ZPO) as cross-linker in the molar ratio of PTMOS/BPA/ZPO/EtOH molar ratio of 1/1/30/80, was infilitraed into the void of the colloidal crystals in N2. Hydrolysis of the precursor solution at a high temperature (60C) and high hymidity (relative humidity: 100 %) leads the imprinted cavities generating at the surface more than in the bulk. The IPC reached an adsorbtion equilibrium within 20 min in 50 mg/L BPA solution, and wavelength shifted from 4.5 to 6.3 nm when the pore diameters increased from 160 to 200 nm (correspondingly the PS size increased from 235 to 305 nm). The optimal IPC exhited two linear rages in 0.5-1.0 mg/L and 1.0-90.0 mg/L, and the detection limit was 0.50 mg/L. Insignificant response for BPA analogues indicates its high selectivity. These results clearly demonstrated that the IPC has high sensitivity and quick response which is promising for in-situ and on-site analysis in the future. Chang, Sue-Min 張淑閔 2013 學位論文 ; thesis 86 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立交通大學 === 環境工程系所 === 102 === In this study, a high sensitive and quick responsive ZrO2 imprinted photonic crystal (IPC) for detection of BPA was developed. The diffraction wavelength shift, resulting from the changes in the refractive index(n) of the IPC after rebinding of BPA, is used for the quantification of the target compound. Polystyrene(PS) microspheres with the sizes in the range of 235-285 nm as the template for inverse opal photonic crystals were prepared using emulsion free and emulsion polymerization method. They self-assembled into opal structure through a heat-assisted method at 50C. Imprinted precursor solution, containing phenyltrimethoxysilane (PTMOS) as the functional monomer and zirconium propoxide (ZPO) as cross-linker in the molar ratio of PTMOS/BPA/ZPO/EtOH molar ratio of 1/1/30/80, was infilitraed into the void of the colloidal crystals in N2. Hydrolysis of the precursor solution at a high temperature (60C) and high hymidity (relative humidity: 100 %) leads the imprinted cavities generating at the surface more than in the bulk. The IPC reached an adsorbtion equilibrium within 20 min in 50 mg/L BPA solution, and wavelength shifted from 4.5 to 6.3 nm when the pore diameters increased from 160 to 200 nm (correspondingly the PS size increased from 235 to 305 nm). The optimal IPC exhited two linear rages in 0.5-1.0 mg/L and 1.0-90.0 mg/L, and the detection limit was 0.50 mg/L. Insignificant response for BPA analogues indicates its high selectivity. These results clearly demonstrated that the IPC has high sensitivity and quick response which is promising for in-situ and on-site analysis in the future.
author2 Chang, Sue-Min
author_facet Chang, Sue-Min
Fang, Chih-Hsiang
方峙翔
author Fang, Chih-Hsiang
方峙翔
spellingShingle Fang, Chih-Hsiang
方峙翔
Lattice-parameter-controlled sensitivities of imprinted photonic crystals for BPA detection
author_sort Fang, Chih-Hsiang
title Lattice-parameter-controlled sensitivities of imprinted photonic crystals for BPA detection
title_short Lattice-parameter-controlled sensitivities of imprinted photonic crystals for BPA detection
title_full Lattice-parameter-controlled sensitivities of imprinted photonic crystals for BPA detection
title_fullStr Lattice-parameter-controlled sensitivities of imprinted photonic crystals for BPA detection
title_full_unstemmed Lattice-parameter-controlled sensitivities of imprinted photonic crystals for BPA detection
title_sort lattice-parameter-controlled sensitivities of imprinted photonic crystals for bpa detection
publishDate 2013
url http://ndltd.ncl.edu.tw/handle/57743510136412379233
work_keys_str_mv AT fangchihhsiang latticeparametercontrolledsensitivitiesofimprintedphotoniccrystalsforbpadetection
AT fāngzhìxiáng latticeparametercontrolledsensitivitiesofimprintedphotoniccrystalsforbpadetection
AT fangchihhsiang jīnggécānshùdiàokòngtàyìnguāngzijīngtǐgǎncèshuāngfēnazhīlíngmǐndù
AT fāngzhìxiáng jīnggécānshùdiàokòngtàyìnguāngzijīngtǐgǎncèshuāngfēnazhīlíngmǐndù
_version_ 1718331941000839168