A Full-Bridge Phase-Shifted Inverter for Induction Heating
碩士 === 國立成功大學 === 電機工程學系 === 102 === The main purpose of this thesis is to study and implement a full-bridge phase-shifted load-parallel-resonant inverter for induction heating. Zero-voltage-switching operation of all switches can be achieved with stray components of the power transformer and four p...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/61123032480087062346 |
id |
ndltd-TW-102NCKU5442151 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102NCKU54421512016-03-07T04:11:05Z http://ndltd.ncl.edu.tw/handle/61123032480087062346 A Full-Bridge Phase-Shifted Inverter for Induction Heating 應用於感應加熱之全橋相移換流器 Chien-ChihChen 陳建智 碩士 國立成功大學 電機工程學系 102 The main purpose of this thesis is to study and implement a full-bridge phase-shifted load-parallel-resonant inverter for induction heating. Zero-voltage-switching operation of all switches can be achieved with stray components of the power transformer and four power switches. Parallel resonance occurs between the load and the resonant capacitor at a resonant frequency equal to the switching frequency, which results in maximum power transfer for induction heating. In this thesis, first, the basic theory of induction heating is introduced. Second, the analysis of operating principles of full-bridge phase-shifted load-parallel-resonant inverter is performed. Then, the design procedure is described. Finally, a prototype of the inverter with input voltage 500 Vdc, output voltage 50 Vrms,ac, and output power 2 kW is implemented to verify the theoretical analysis. Jiann-Fuh Chen 陳建富 2014 學位論文 ; thesis 62 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 電機工程學系 === 102 === The main purpose of this thesis is to study and implement a full-bridge phase-shifted load-parallel-resonant inverter for induction heating. Zero-voltage-switching operation of all switches can be achieved with stray components of the power transformer and four power switches. Parallel resonance occurs between the load and the resonant capacitor at a resonant frequency equal to the switching frequency, which results in maximum power transfer for induction heating. In this thesis, first, the basic theory of induction heating is introduced. Second, the analysis of operating principles of full-bridge phase-shifted load-parallel-resonant inverter is performed. Then, the design procedure is described. Finally, a prototype of the inverter with input voltage 500 Vdc, output voltage 50 Vrms,ac, and output power 2 kW is implemented to verify the theoretical analysis.
|
author2 |
Jiann-Fuh Chen |
author_facet |
Jiann-Fuh Chen Chien-ChihChen 陳建智 |
author |
Chien-ChihChen 陳建智 |
spellingShingle |
Chien-ChihChen 陳建智 A Full-Bridge Phase-Shifted Inverter for Induction Heating |
author_sort |
Chien-ChihChen |
title |
A Full-Bridge Phase-Shifted Inverter for Induction Heating |
title_short |
A Full-Bridge Phase-Shifted Inverter for Induction Heating |
title_full |
A Full-Bridge Phase-Shifted Inverter for Induction Heating |
title_fullStr |
A Full-Bridge Phase-Shifted Inverter for Induction Heating |
title_full_unstemmed |
A Full-Bridge Phase-Shifted Inverter for Induction Heating |
title_sort |
full-bridge phase-shifted inverter for induction heating |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/61123032480087062346 |
work_keys_str_mv |
AT chienchihchen afullbridgephaseshiftedinverterforinductionheating AT chénjiànzhì afullbridgephaseshiftedinverterforinductionheating AT chienchihchen yīngyòngyúgǎnyīngjiārèzhīquánqiáoxiāngyíhuànliúqì AT chénjiànzhì yīngyòngyúgǎnyīngjiārèzhīquánqiáoxiāngyíhuànliúqì AT chienchihchen fullbridgephaseshiftedinverterforinductionheating AT chénjiànzhì fullbridgephaseshiftedinverterforinductionheating |
_version_ |
1718199608384946176 |