Application of Resistivity Image Profiling Method to Understand the Underground Electrical Distribution of Chihshang Fault at Tien-Kuang
碩士 === 國立成功大學 === 地球科學系 === 102 === Taiwan is located between the Eurasian Plate and the Philippine Sea plate, Longitudinal Valley Fault in Taiwan is a common geological structure. Because of creep characteristic, most of geological surveys in this area to date. Chihshang Fault probably has more tha...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/43802256375806839883 |
id |
ndltd-TW-102NCKU5135154 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102NCKU51351542015-10-14T00:12:48Z http://ndltd.ncl.edu.tw/handle/43802256375806839883 Application of Resistivity Image Profiling Method to Understand the Underground Electrical Distribution of Chihshang Fault at Tien-Kuang 應用地電阻法初勘池上斷層在電光地區地下電性分佈 Jui-ChiLin 林瑞騏 碩士 國立成功大學 地球科學系 102 Taiwan is located between the Eurasian Plate and the Philippine Sea plate, Longitudinal Valley Fault in Taiwan is a common geological structure. Because of creep characteristic, most of geological surveys in this area to date. Chihshang Fault probably has more than one fault line like different branches and small faults. We use “Resistivity” to describe the electrical properties of material and matters. In this study we use digital ground resistivity meter to detect the area at Tien-Kuang in Chihshang in Taitung. Input this survey data, we use an iterative program to output the resistivity model, finally produce resistivity image profile,RIP. We set three lines at Tien-Kuang in this study. Bounded by rupture observed in ditches, in the north is line 107 and 108, the south is line 101. Through the program processing, the thickness of the alluvial layer with high resistivity is about 30 meters in this area. Under this layer is a low resistivity layer. The thickness is about 100 meters. There is an electrical discontinuity about 50 to 60 meters in the west side of this survey lines. These surface rupture should be producing by Chihshang fault when acting. Ting-Li Lin 樂鍇‧祿璞崚岸 2014 學位論文 ; thesis 69 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立成功大學 === 地球科學系 === 102 === Taiwan is located between the Eurasian Plate and the Philippine Sea plate, Longitudinal Valley Fault in Taiwan is a common geological structure. Because of creep characteristic, most of geological surveys in this area to date. Chihshang Fault probably has more than one fault line like different branches and small faults.
We use “Resistivity” to describe the electrical properties of material and matters. In this study we use digital ground resistivity meter to detect the area at Tien-Kuang in Chihshang in Taitung. Input this survey data, we use an iterative program to output the resistivity model, finally produce resistivity image profile,RIP.
We set three lines at Tien-Kuang in this study. Bounded by rupture observed in ditches, in the north is line 107 and 108, the south is line 101. Through the program processing, the thickness of the alluvial layer with high resistivity is about 30 meters in this area. Under this layer is a low resistivity layer. The thickness is about 100 meters. There is an electrical discontinuity about 50 to 60 meters in the west side of this survey lines. These surface rupture should be producing by Chihshang fault when acting.
|
author2 |
Ting-Li Lin |
author_facet |
Ting-Li Lin Jui-ChiLin 林瑞騏 |
author |
Jui-ChiLin 林瑞騏 |
spellingShingle |
Jui-ChiLin 林瑞騏 Application of Resistivity Image Profiling Method to Understand the Underground Electrical Distribution of Chihshang Fault at Tien-Kuang |
author_sort |
Jui-ChiLin |
title |
Application of Resistivity Image Profiling Method to Understand the Underground Electrical Distribution of Chihshang Fault at Tien-Kuang |
title_short |
Application of Resistivity Image Profiling Method to Understand the Underground Electrical Distribution of Chihshang Fault at Tien-Kuang |
title_full |
Application of Resistivity Image Profiling Method to Understand the Underground Electrical Distribution of Chihshang Fault at Tien-Kuang |
title_fullStr |
Application of Resistivity Image Profiling Method to Understand the Underground Electrical Distribution of Chihshang Fault at Tien-Kuang |
title_full_unstemmed |
Application of Resistivity Image Profiling Method to Understand the Underground Electrical Distribution of Chihshang Fault at Tien-Kuang |
title_sort |
application of resistivity image profiling method to understand the underground electrical distribution of chihshang fault at tien-kuang |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/43802256375806839883 |
work_keys_str_mv |
AT juichilin applicationofresistivityimageprofilingmethodtounderstandtheundergroundelectricaldistributionofchihshangfaultattienkuang AT línruìqí applicationofresistivityimageprofilingmethodtounderstandtheundergroundelectricaldistributionofchihshangfaultattienkuang AT juichilin yīngyòngdediànzǔfǎchūkānchíshàngduàncéngzàidiànguāngdeqūdexiàdiànxìngfēnbù AT línruìqí yīngyòngdediànzǔfǎchūkānchíshàngduàncéngzàidiànguāngdeqūdexiàdiànxìngfēnbù |
_version_ |
1718087662955397120 |