An Empirical Study on Seismic Load Reduction Factors for SDOF and MDOF systems

博士 === 國立成功大學 === 土木工程學系 === 102 === For the purpose of safety and economy, the plastic deformations of buildings are allowed to reduce seismic loads. When the ductility design is applied, the domestic building seismic design code provides formulas to estimate the seismic load reduction factor by t...

Full description

Bibliographic Details
Main Authors: Pai-YiHuang, 黃百誼
Other Authors: Li-Ling Hong
Format: Others
Language:en_US
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/09085235664678840780
id ndltd-TW-102NCKU5015001
record_format oai_dc
spelling ndltd-TW-102NCKU50150012016-07-02T04:20:39Z http://ndltd.ncl.edu.tw/handle/09085235664678840780 An Empirical Study on Seismic Load Reduction Factors for SDOF and MDOF systems 單自由度和多自由度系統地震力折減係數之經驗公式研究 Pai-YiHuang 黃百誼 博士 國立成功大學 土木工程學系 102 For the purpose of safety and economy, the plastic deformations of buildings are allowed to reduce seismic loads. When the ductility design is applied, the domestic building seismic design code provides formulas to estimate the seismic load reduction factor by the ductility capacity, and then the seismic load is reduced from the elastic design spectrum. The relationship of the seismic load reduction factor on the ductility capacity depends on the ground motions, so it is necessary to investigate the code formulas or propose a new one on the basis of the elastic design spectrum. This paper proposes an improved Kaul’s method to efficiently generate artificial earthquakes compatible with the design spectra. The original ground accelerograms come from seismic records of TSMIP operated by CWB, and are modified as less as possible in our method. Over than one thousand artificial ground accelerograms are generated and then are classified by different site conditions and design spectra. Through the nonlinear response history analysis on SDOF systems, a lot of seismic load reduction factors corresponding to different parameters, such as natural vibration period, ductility capacity, and stiffness ratio, are obtained for further study. Through the sensitivity analysis on parameters, it is found that the seismic load reduction factor is highly correlated to system properties. On the basis of regression results, a tri-linear relationship of the mean seismic load reduction factor on the normalized natural vibration period is proposed, and the two transition periods locate exactly at both ends of the platform in the elastic response spectra. The code formula generally underestimates the seismic load reduction factor on the short-period region, but our formula considers a compromise between safety and economy. On the other hand, it is observed that the response results of MDOF systems by the static analysis and the response spectrum analysis are more conservative than those by the nonlinear response history analysis. It is also found in the nonlinear response history analysis that only the ductility capacities of the lower stories are well used if the building is designed with uniform story shear yield strength. This paper provides an optimum design procedure to calculate the story shear yield strength in order for achieving the same ductility capacity in each story. Finally, for uniform shear buildings a formula of optimal distribution of the story shear yield strength ratio is proposed. Li-Ling Hong 洪李陵 2014 學位論文 ; thesis 194 en_US
collection NDLTD
language en_US
format Others
sources NDLTD
description 博士 === 國立成功大學 === 土木工程學系 === 102 === For the purpose of safety and economy, the plastic deformations of buildings are allowed to reduce seismic loads. When the ductility design is applied, the domestic building seismic design code provides formulas to estimate the seismic load reduction factor by the ductility capacity, and then the seismic load is reduced from the elastic design spectrum. The relationship of the seismic load reduction factor on the ductility capacity depends on the ground motions, so it is necessary to investigate the code formulas or propose a new one on the basis of the elastic design spectrum. This paper proposes an improved Kaul’s method to efficiently generate artificial earthquakes compatible with the design spectra. The original ground accelerograms come from seismic records of TSMIP operated by CWB, and are modified as less as possible in our method. Over than one thousand artificial ground accelerograms are generated and then are classified by different site conditions and design spectra. Through the nonlinear response history analysis on SDOF systems, a lot of seismic load reduction factors corresponding to different parameters, such as natural vibration period, ductility capacity, and stiffness ratio, are obtained for further study. Through the sensitivity analysis on parameters, it is found that the seismic load reduction factor is highly correlated to system properties. On the basis of regression results, a tri-linear relationship of the mean seismic load reduction factor on the normalized natural vibration period is proposed, and the two transition periods locate exactly at both ends of the platform in the elastic response spectra. The code formula generally underestimates the seismic load reduction factor on the short-period region, but our formula considers a compromise between safety and economy. On the other hand, it is observed that the response results of MDOF systems by the static analysis and the response spectrum analysis are more conservative than those by the nonlinear response history analysis. It is also found in the nonlinear response history analysis that only the ductility capacities of the lower stories are well used if the building is designed with uniform story shear yield strength. This paper provides an optimum design procedure to calculate the story shear yield strength in order for achieving the same ductility capacity in each story. Finally, for uniform shear buildings a formula of optimal distribution of the story shear yield strength ratio is proposed.
author2 Li-Ling Hong
author_facet Li-Ling Hong
Pai-YiHuang
黃百誼
author Pai-YiHuang
黃百誼
spellingShingle Pai-YiHuang
黃百誼
An Empirical Study on Seismic Load Reduction Factors for SDOF and MDOF systems
author_sort Pai-YiHuang
title An Empirical Study on Seismic Load Reduction Factors for SDOF and MDOF systems
title_short An Empirical Study on Seismic Load Reduction Factors for SDOF and MDOF systems
title_full An Empirical Study on Seismic Load Reduction Factors for SDOF and MDOF systems
title_fullStr An Empirical Study on Seismic Load Reduction Factors for SDOF and MDOF systems
title_full_unstemmed An Empirical Study on Seismic Load Reduction Factors for SDOF and MDOF systems
title_sort empirical study on seismic load reduction factors for sdof and mdof systems
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/09085235664678840780
work_keys_str_mv AT paiyihuang anempiricalstudyonseismicloadreductionfactorsforsdofandmdofsystems
AT huángbǎiyì anempiricalstudyonseismicloadreductionfactorsforsdofandmdofsystems
AT paiyihuang dānzìyóudùhéduōzìyóudùxìtǒngdezhènlìzhéjiǎnxìshùzhījīngyàngōngshìyánjiū
AT huángbǎiyì dānzìyóudùhéduōzìyóudùxìtǒngdezhènlìzhéjiǎnxìshùzhījīngyàngōngshìyánjiū
AT paiyihuang empiricalstudyonseismicloadreductionfactorsforsdofandmdofsystems
AT huángbǎiyì empiricalstudyonseismicloadreductionfactorsforsdofandmdofsystems
_version_ 1718332186715750400