Investigation of the Non-Invasive Measurement of Arterial Endothelial Vasodilatation
碩士 === 義守大學 === 生物醫學工程學系 === 102 === Vascular endothelial dysfunction has been shown to be an early indicator of atherosclerosis as well as a risk factor of cardiovascular disease. In the clinical trials, 33 subjects (Control group: N=26, Patient group: N=7) were recruited and asked to undergo a 5-m...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/32875488287811947679 |
id |
ndltd-TW-102ISU05114008 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102ISU051140082015-10-14T00:23:51Z http://ndltd.ncl.edu.tw/handle/32875488287811947679 Investigation of the Non-Invasive Measurement of Arterial Endothelial Vasodilatation 非侵入式測量動脈內皮細胞舒張功能之研究 Jia-Fu Yang 楊家福 碩士 義守大學 生物醫學工程學系 102 Vascular endothelial dysfunction has been shown to be an early indicator of atherosclerosis as well as a risk factor of cardiovascular disease. In the clinical trials, 33 subjects (Control group: N=26, Patient group: N=7) were recruited and asked to undergo a 5-minute occlusion of the brachial artery. The flow-mediated dilatation (FMD) was assessed by the air cuff oscillometry, the photo-plethysmography (PPG) and the ultrasound, respectively. Another 30 normal and young participants were asked to perform 1, 3 and 5-minute occlusion of the brachial artery to observe the occlusion effects on FMD. Experimental results showed that the oscillometry-based FMD of the radial artery was significantly greater in the Control group than in the Patient group (129±35 vs 92±31 %, p=0.009). However, there was no significant difference in the PPG-based FMD of the finger artery together with microcirculation between the two groups. After the 5-minute occlusion, the Control group had significantly larger maximum reaction time than that in the Patient group (54±10 vs 23±6 sec, p<0.001). For the 30 normal and young participants, their FMD through a 3-minute occlusion of the brachial artery was significantly smaller than that through a 5-minute occlusion (p<0.001), but not with that through a 1-minute occlusion. In summary, the proposed air cuff oscillometry can be used to effectively assess the endothelial FMD of a conduit artery. Jia-Jung Wang 王家鍾 2014 學位論文 ; thesis 75 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 義守大學 === 生物醫學工程學系 === 102 === Vascular endothelial dysfunction has been shown to be an early indicator of atherosclerosis as well as a risk factor of cardiovascular disease. In the clinical trials, 33 subjects (Control group: N=26, Patient group: N=7) were recruited and asked to undergo a 5-minute occlusion of the brachial artery. The flow-mediated dilatation (FMD) was assessed by the air cuff oscillometry, the photo-plethysmography (PPG) and the ultrasound, respectively. Another 30 normal and young participants were asked to perform 1, 3 and 5-minute occlusion of the brachial artery to observe the occlusion effects on FMD. Experimental results showed that the oscillometry-based FMD of the radial artery was significantly greater in the Control group than in the Patient group (129±35 vs 92±31 %, p=0.009). However, there was no significant difference in the PPG-based FMD of the finger artery together with microcirculation between the two groups. After the 5-minute occlusion, the Control group had significantly larger maximum reaction time than that in the Patient group (54±10 vs 23±6 sec, p<0.001). For the 30 normal and young participants, their FMD through a 3-minute occlusion of the brachial artery was significantly smaller than that through a 5-minute occlusion (p<0.001), but not with that through a 1-minute occlusion. In summary, the proposed air cuff oscillometry can be used to effectively assess the endothelial FMD of a conduit artery.
|
author2 |
Jia-Jung Wang |
author_facet |
Jia-Jung Wang Jia-Fu Yang 楊家福 |
author |
Jia-Fu Yang 楊家福 |
spellingShingle |
Jia-Fu Yang 楊家福 Investigation of the Non-Invasive Measurement of Arterial Endothelial Vasodilatation |
author_sort |
Jia-Fu Yang |
title |
Investigation of the Non-Invasive Measurement of Arterial Endothelial Vasodilatation |
title_short |
Investigation of the Non-Invasive Measurement of Arterial Endothelial Vasodilatation |
title_full |
Investigation of the Non-Invasive Measurement of Arterial Endothelial Vasodilatation |
title_fullStr |
Investigation of the Non-Invasive Measurement of Arterial Endothelial Vasodilatation |
title_full_unstemmed |
Investigation of the Non-Invasive Measurement of Arterial Endothelial Vasodilatation |
title_sort |
investigation of the non-invasive measurement of arterial endothelial vasodilatation |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/32875488287811947679 |
work_keys_str_mv |
AT jiafuyang investigationofthenoninvasivemeasurementofarterialendothelialvasodilatation AT yángjiāfú investigationofthenoninvasivemeasurementofarterialendothelialvasodilatation AT jiafuyang fēiqīnrùshìcèliàngdòngmàinèipíxìbāoshūzhānggōngnéngzhīyánjiū AT yángjiāfú fēiqīnrùshìcèliàngdòngmàinèipíxìbāoshūzhānggōngnéngzhīyánjiū |
_version_ |
1718089125185191936 |