Application of Water and Soil Interfacer on Riverbed Variations Measurement

碩士 === 逢甲大學 === 水利工程與資源保育學系 === 102 ===   Rivers are steep with rapid flows in Taiwan due to the geographical reasons. Severe variations in a streambed may have negative effects on the safety and stability of hydraulic structures and land beside the river. For example, the foundations of bridge pier...

Full description

Bibliographic Details
Main Authors: LIU, WEI-TING, 劉韋廷
Other Authors: WANG, CHUAN-YI
Format: Others
Language:zh-TW
Published: 2014
Online Access:http://ndltd.ncl.edu.tw/handle/03833820615599122481
id ndltd-TW-102FCU05398012
record_format oai_dc
spelling ndltd-TW-102FCU053980122015-10-13T23:49:49Z http://ndltd.ncl.edu.tw/handle/03833820615599122481 Application of Water and Soil Interfacer on Riverbed Variations Measurement 水土界面儀應用於河床沖淤量測之研究 LIU, WEI-TING 劉韋廷 碩士 逢甲大學 水利工程與資源保育學系 102   Rivers are steep with rapid flows in Taiwan due to the geographical reasons. Severe variations in a streambed may have negative effects on the safety and stability of hydraulic structures and land beside the river. For example, the foundations of bridge piers and levees may collapse due to severe scours. The flood disaster can be reduced if the riverbed variation tendency can be properly evaluated based on the field measurements. The objective of this study is to develop a durable and reliable measuring technique - water and soil interface monitoring system. Formulas for the prediction of general scour can be developed based on these field data. Hopefully, it can be served as a reference of structure design for relevant engineers in the future.   The results show that the scour depth can be accurately detected under different types of unsteady flows in the laboratory. The system is able to measure the back silting without digging the river bed. The instrument of water and soil interface was installed in the main channel of the Cho-Shui River downstream of Tzu-Chiang Bridge. The test result in the field shows that it can accurately detect the water level and the riverbed elevation. The water level obtained from the water and soil interface monitoring system is consistent with that measured by the Fourth River Management Bureau (WRA) of typhoon Soulik (2013). Although the water level had exceeded the maximum elevation of 12.767 meters, the riverbed was still detectable, and a scour depth of 1.12 meters was measured after 2 hours of observation. Overall, the system is feasible to measure the real time dynamic general scour depth of riverbed during a flood event. WANG, CHUAN-YI 王傳益 2014 學位論文 ; thesis 117 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 逢甲大學 === 水利工程與資源保育學系 === 102 ===   Rivers are steep with rapid flows in Taiwan due to the geographical reasons. Severe variations in a streambed may have negative effects on the safety and stability of hydraulic structures and land beside the river. For example, the foundations of bridge piers and levees may collapse due to severe scours. The flood disaster can be reduced if the riverbed variation tendency can be properly evaluated based on the field measurements. The objective of this study is to develop a durable and reliable measuring technique - water and soil interface monitoring system. Formulas for the prediction of general scour can be developed based on these field data. Hopefully, it can be served as a reference of structure design for relevant engineers in the future.   The results show that the scour depth can be accurately detected under different types of unsteady flows in the laboratory. The system is able to measure the back silting without digging the river bed. The instrument of water and soil interface was installed in the main channel of the Cho-Shui River downstream of Tzu-Chiang Bridge. The test result in the field shows that it can accurately detect the water level and the riverbed elevation. The water level obtained from the water and soil interface monitoring system is consistent with that measured by the Fourth River Management Bureau (WRA) of typhoon Soulik (2013). Although the water level had exceeded the maximum elevation of 12.767 meters, the riverbed was still detectable, and a scour depth of 1.12 meters was measured after 2 hours of observation. Overall, the system is feasible to measure the real time dynamic general scour depth of riverbed during a flood event.
author2 WANG, CHUAN-YI
author_facet WANG, CHUAN-YI
LIU, WEI-TING
劉韋廷
author LIU, WEI-TING
劉韋廷
spellingShingle LIU, WEI-TING
劉韋廷
Application of Water and Soil Interfacer on Riverbed Variations Measurement
author_sort LIU, WEI-TING
title Application of Water and Soil Interfacer on Riverbed Variations Measurement
title_short Application of Water and Soil Interfacer on Riverbed Variations Measurement
title_full Application of Water and Soil Interfacer on Riverbed Variations Measurement
title_fullStr Application of Water and Soil Interfacer on Riverbed Variations Measurement
title_full_unstemmed Application of Water and Soil Interfacer on Riverbed Variations Measurement
title_sort application of water and soil interfacer on riverbed variations measurement
publishDate 2014
url http://ndltd.ncl.edu.tw/handle/03833820615599122481
work_keys_str_mv AT liuweiting applicationofwaterandsoilinterfaceronriverbedvariationsmeasurement
AT liúwéitíng applicationofwaterandsoilinterfaceronriverbedvariationsmeasurement
AT liuweiting shuǐtǔjièmiànyíyīngyòngyúhéchuángchōngyūliàngcèzhīyánjiū
AT liúwéitíng shuǐtǔjièmiànyíyīngyòngyúhéchuángchōngyūliàngcèzhīyánjiū
_version_ 1718087128498307072