Application of Lyophilization Techniques for Pre-storage of Low Volume Reagent on the Microfluidic Chip
碩士 === 逢甲大學 === 化學工程學系 === 102 === The purpose of this study is to develop a technology for reagent storage on a microfluidic disk for point-of-care (POC) diagnostics. In most of the POC devices, samples and reagents need to be added into the disc separately before testing. This could be labor-int...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/19736785483048770584 |
id |
ndltd-TW-102FCU05063008 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102FCU050630082015-10-13T23:49:49Z http://ndltd.ncl.edu.tw/handle/19736785483048770584 Application of Lyophilization Techniques for Pre-storage of Low Volume Reagent on the Microfluidic Chip 於微流體晶片上應用冷凍乾燥技術發展微量藥劑之預儲存方式 Lu, Wei-Han 陸韋翰 碩士 逢甲大學 化學工程學系 102 The purpose of this study is to develop a technology for reagent storage on a microfluidic disk for point-of-care (POC) diagnostics. In most of the POC devices, samples and reagents need to be added into the disc separately before testing. This could be labor-intensive and time-consuming especially when many tests were integrated on the same device. In order to make the POC device more user-friendly, it is desired to have the reagents stored on the device. In this study, we explore the lyophilization technology for reagent pre-storage on the micro-devices. Experimental results showed that the test results from the devices with lyophilized reagent were similar to the one with liquid reagents. 施志欣 2014 學位論文 ; thesis 44 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 逢甲大學 === 化學工程學系 === 102 === The purpose of this study is to develop a technology for reagent storage on a microfluidic disk for point-of-care (POC) diagnostics. In most of the POC devices, samples and reagents need to be added into the disc separately before testing. This could be labor-intensive and time-consuming especially when many tests were integrated on the same device. In order to make the POC device more user-friendly, it is desired to have the reagents stored on the device. In this study, we explore the lyophilization technology for reagent pre-storage on the micro-devices. Experimental results showed that the test results from the devices with lyophilized reagent were similar to the one with liquid reagents.
|
author2 |
施志欣 |
author_facet |
施志欣 Lu, Wei-Han 陸韋翰 |
author |
Lu, Wei-Han 陸韋翰 |
spellingShingle |
Lu, Wei-Han 陸韋翰 Application of Lyophilization Techniques for Pre-storage of Low Volume Reagent on the Microfluidic Chip |
author_sort |
Lu, Wei-Han |
title |
Application of Lyophilization Techniques for Pre-storage of Low Volume Reagent on the Microfluidic Chip |
title_short |
Application of Lyophilization Techniques for Pre-storage of Low Volume Reagent on the Microfluidic Chip |
title_full |
Application of Lyophilization Techniques for Pre-storage of Low Volume Reagent on the Microfluidic Chip |
title_fullStr |
Application of Lyophilization Techniques for Pre-storage of Low Volume Reagent on the Microfluidic Chip |
title_full_unstemmed |
Application of Lyophilization Techniques for Pre-storage of Low Volume Reagent on the Microfluidic Chip |
title_sort |
application of lyophilization techniques for pre-storage of low volume reagent on the microfluidic chip |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/19736785483048770584 |
work_keys_str_mv |
AT luweihan applicationoflyophilizationtechniquesforprestorageoflowvolumereagentonthemicrofluidicchip AT lùwéihàn applicationoflyophilizationtechniquesforprestorageoflowvolumereagentonthemicrofluidicchip AT luweihan yúwēiliútǐjīngpiànshàngyīngyònglěngdònggānzàojìshùfāzhǎnwēiliàngyàojìzhīyùchǔcúnfāngshì AT lùwéihàn yúwēiliútǐjīngpiànshàngyīngyònglěngdònggānzàojìshùfāzhǎnwēiliàngyàojìzhīyùchǔcúnfāngshì |
_version_ |
1718086995527335936 |