A feasibility study of the CTDI measurement by nMAG gel dosimeter
碩士 === 中國醫藥大學 === 臨床醫學研究所碩士班 === 102 === Computer tomography dose index (CTDI) measurement and slice width profile(SWP) assemsment are parts of acceptance test and quality assurance measurements of diagnostic x-ray CT scanners for the determination of patient dose. Normoxic polymer gel dosimeters ha...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2014
|
Online Access: | http://ndltd.ncl.edu.tw/handle/nwt8d3 |
id |
ndltd-TW-102CMCH5521017 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-102CMCH55210172019-09-02T04:21:38Z http://ndltd.ncl.edu.tw/handle/nwt8d3 A feasibility study of the CTDI measurement by nMAG gel dosimeter 評估nMAG凝膠劑量計應用於電腦斷層指標之可行性 Yu-Chen Yeh 葉昱溱 碩士 中國醫藥大學 臨床醫學研究所碩士班 102 Computer tomography dose index (CTDI) measurement and slice width profile(SWP) assemsment are parts of acceptance test and quality assurance measurements of diagnostic x-ray CT scanners for the determination of patient dose. Normoxic polymer gel dosimeters have been proven it has the potential to measure dose and evaluate CTDI during acceptance testing. In this study, we used nMAG gel dosimeter to measure Computer tomography dose index (CTDI)and slice width profile(SWP). The 1.5T MRI scan with the head coil receiver was used to readout the dose information.The results shows the difference of CTDI100 calculated from the normoxic polymer gel dosimeter and 10 cm pencil ion chamber was in 10%. Full-width half-maximum(FWHM) values of slice width profiles from the normoxic polymer gel dosimeter were compared to FWHM values from Gafchromic film, the difference was in 10%. We conclude that polymer gel dosimeters shows great potential as a technique to assess dose distribution of computed tomography. Jay Wu 吳杰 2014 學位論文 ; thesis 40 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 中國醫藥大學 === 臨床醫學研究所碩士班 === 102 === Computer tomography dose index (CTDI) measurement and slice width profile(SWP) assemsment are parts of acceptance test and quality assurance measurements of diagnostic x-ray CT scanners for the determination of patient dose. Normoxic polymer gel dosimeters have been proven it has the potential to measure dose and evaluate CTDI during acceptance testing.
In this study, we used nMAG gel dosimeter to measure Computer tomography dose index (CTDI)and slice width profile(SWP). The 1.5T MRI scan with the head coil receiver was used to readout the dose information.The results shows the difference of CTDI100 calculated from the normoxic polymer gel dosimeter and 10 cm pencil ion chamber was in 10%. Full-width half-maximum(FWHM) values of slice width profiles from the normoxic polymer gel dosimeter were compared to FWHM values from Gafchromic film, the difference was in 10%.
We conclude that polymer gel dosimeters shows great potential as a technique to assess dose distribution of computed tomography.
|
author2 |
Jay Wu |
author_facet |
Jay Wu Yu-Chen Yeh 葉昱溱 |
author |
Yu-Chen Yeh 葉昱溱 |
spellingShingle |
Yu-Chen Yeh 葉昱溱 A feasibility study of the CTDI measurement by nMAG gel dosimeter |
author_sort |
Yu-Chen Yeh |
title |
A feasibility study of the CTDI measurement by nMAG gel dosimeter |
title_short |
A feasibility study of the CTDI measurement by nMAG gel dosimeter |
title_full |
A feasibility study of the CTDI measurement by nMAG gel dosimeter |
title_fullStr |
A feasibility study of the CTDI measurement by nMAG gel dosimeter |
title_full_unstemmed |
A feasibility study of the CTDI measurement by nMAG gel dosimeter |
title_sort |
feasibility study of the ctdi measurement by nmag gel dosimeter |
publishDate |
2014 |
url |
http://ndltd.ncl.edu.tw/handle/nwt8d3 |
work_keys_str_mv |
AT yuchenyeh afeasibilitystudyofthectdimeasurementbynmaggeldosimeter AT yèyùqín afeasibilitystudyofthectdimeasurementbynmaggeldosimeter AT yuchenyeh pínggūnmagníngjiāojìliàngjìyīngyòngyúdiànnǎoduàncéngzhǐbiāozhīkěxíngxìng AT yèyùqín pínggūnmagníngjiāojìliàngjìyīngyòngyúdiànnǎoduàncéngzhǐbiāozhīkěxíngxìng AT yuchenyeh feasibilitystudyofthectdimeasurementbynmaggeldosimeter AT yèyùqín feasibilitystudyofthectdimeasurementbynmaggeldosimeter |
_version_ |
1719242477734461440 |