Energy-saving Analysis on a Data Center of Taipei MRT Control Center

碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 101 === MRT control data center is about 1986 planning period, compared with today''s new setting data of the device has been a great difference in the cost of through analysis, planning, and for the most economical use of energy is more sophis...

Full description

Bibliographic Details
Main Authors: HUNG-JUNG HSU, 許洪榮
Other Authors: 施陽正
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/e4pkz3
id ndltd-TW-101TIT05703040
record_format oai_dc
spelling ndltd-TW-101TIT057030402019-05-15T21:02:30Z http://ndltd.ncl.edu.tw/handle/e4pkz3 Energy-saving Analysis on a Data Center of Taipei MRT Control Center 捷運行控數據中心節能分析 HUNG-JUNG HSU 許洪榮 碩士 國立臺北科技大學 能源與冷凍空調工程系碩士班 101 MRT control data center is about 1986 planning period, compared with today''s new setting data of the device has been a great difference in the cost of through analysis, planning, and for the most economical use of energy is more sophisticated, so that the overall cost can be effectively reduced. This thesis analyzes carried out by computer simulation CFD assisted planning and design, the device can not be run in an existing power off and should be kept under continuous operation can be simulated and analyzed to adjust, and to assess the optimal air box set temperature conditions, with the energy-saving targets , to meet international standards of energy efficient data centers, from the simulation results forecast future data center energy efficiency improvement potential, thus reducing data center operating costs. In this study, CFD simulation software on the Taipei MRT control type room raised floor data center simulation analysis and study the air box failure on the device temperature impact resistance, and can be contacted by simulation analysis to identify energy-saving strategies. 施陽正 2013 學位論文 ; thesis 50 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 101 === MRT control data center is about 1986 planning period, compared with today''s new setting data of the device has been a great difference in the cost of through analysis, planning, and for the most economical use of energy is more sophisticated, so that the overall cost can be effectively reduced. This thesis analyzes carried out by computer simulation CFD assisted planning and design, the device can not be run in an existing power off and should be kept under continuous operation can be simulated and analyzed to adjust, and to assess the optimal air box set temperature conditions, with the energy-saving targets , to meet international standards of energy efficient data centers, from the simulation results forecast future data center energy efficiency improvement potential, thus reducing data center operating costs. In this study, CFD simulation software on the Taipei MRT control type room raised floor data center simulation analysis and study the air box failure on the device temperature impact resistance, and can be contacted by simulation analysis to identify energy-saving strategies.
author2 施陽正
author_facet 施陽正
HUNG-JUNG HSU
許洪榮
author HUNG-JUNG HSU
許洪榮
spellingShingle HUNG-JUNG HSU
許洪榮
Energy-saving Analysis on a Data Center of Taipei MRT Control Center
author_sort HUNG-JUNG HSU
title Energy-saving Analysis on a Data Center of Taipei MRT Control Center
title_short Energy-saving Analysis on a Data Center of Taipei MRT Control Center
title_full Energy-saving Analysis on a Data Center of Taipei MRT Control Center
title_fullStr Energy-saving Analysis on a Data Center of Taipei MRT Control Center
title_full_unstemmed Energy-saving Analysis on a Data Center of Taipei MRT Control Center
title_sort energy-saving analysis on a data center of taipei mrt control center
publishDate 2013
url http://ndltd.ncl.edu.tw/handle/e4pkz3
work_keys_str_mv AT hungjunghsu energysavinganalysisonadatacenteroftaipeimrtcontrolcenter
AT xǔhóngróng energysavinganalysisonadatacenteroftaipeimrtcontrolcenter
AT hungjunghsu jiéyùnxíngkòngshùjùzhōngxīnjiénéngfēnxī
AT xǔhóngróng jiéyùnxíngkòngshùjùzhōngxīnjiénéngfēnxī
_version_ 1719108039524483072