The influence factor of convenience store power consumption in Taiwan

碩士 === 國立臺北科技大學 === 建築與都市設計研究所 === 101 === In this study, the energy monitoring and management system for to read shopenvironment and equipment electricity information, energy consumption in order to understand the convenience store. This study screened 30 of the regional location of the convenience...

Full description

Bibliographic Details
Main Authors: Chih-Yung Hsu, 徐智勇
Other Authors: Ding-Chin CHOU
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/8bd4q8
Description
Summary:碩士 === 國立臺北科技大學 === 建築與都市設計研究所 === 101 === In this study, the energy monitoring and management system for to read shopenvironment and equipment electricity information, energy consumption in order to understand the convenience store. This study screened 30 of the regional location of the convenience store measured, the first analysis of the relationship between the physical environment. Finally, the measurement results usingthe SPSS18 statistical software regression analysis pulled out the most relevant factor, and energy evaluation system established convenience store for future access to show design reference. Monthly electricity consumption through the Power Monitoring understand theconvenience store business district power consumption from the future to see the average commercial electricity consumption of 21,619.06 (kW/month), residential type 20,038.5 (kW/month, suburban 20,473.9 (kW/month), roads 20,095.6 (kW/month). In addition, the convenience store volume high and low power consumption is actually related to length of shop equipment use time, that is the pattern of electricity consumption is the most critical factors of energy consumption level of convenience stores. A convenience store equipment type to see frozen possession of the equipment usually has a number of high-wattage characteristics, the frozen reservoirs equipment electricity density facilitate up to 88.58 (W/m2) all device types, space lighting to 19.15 (W/m2), other equipment 37.91 (W/m2), air conditioning equipment for 53.73 (W/m2), hot food equipment 57.34 (W/m2). Finally, this study can easily create energy evaluation system operation, and contribute to the promotion of government energy-saving work. Can be set through EXCEL good form, fill in the relevant data to understand the power consumption of convenience stores composed of too high energy-consuming equipment replacement or change undesirable pattern of electricity consumption in a timely manner own.