Disinfection in Cooling Tower by Chlorine Dioxide:Performance Evaluation

碩士 === 國立交通大學 === 工學院永續環境科技學程 === 101 === The chiller has always been the most powerful consumption operation unit among the factories. One of the most important parameter to remain the chiller operation efficiency is the approach temperature. During the operation, circulating water through cooling...

Full description

Bibliographic Details
Main Authors: Chou, Wen-Cheng, 周文朕
Other Authors: Huang, Chih-Pin
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/c8zdu5
id ndltd-TW-101NCTU5087091
record_format oai_dc
spelling ndltd-TW-101NCTU50870912019-05-15T21:02:53Z http://ndltd.ncl.edu.tw/handle/c8zdu5 Disinfection in Cooling Tower by Chlorine Dioxide:Performance Evaluation 二氧化氯殺菌效能應用於冷卻水塔之實廠評估 Chou, Wen-Cheng 周文朕 碩士 國立交通大學 工學院永續環境科技學程 101 The chiller has always been the most powerful consumption operation unit among the factories. One of the most important parameter to remain the chiller operation efficiency is the approach temperature. During the operation, circulating water through cooling towers for heat exchanged is needed, therefore it has become the significantly important to keep good water quality by cooling tower, particularly the total bacterial count. Bacteria growth has become biofilm attached inside copper pipe within heat exchange unit, it will cause not only additional power consumption but also pipe corrosion. Conventionally, sodium hypochlorite (NaOCl) is the mostly used for disinfectants to water treatment since it’s very cheap and easy to access, however, we are short of the research of cooling tower operation by chlorine dioxide in Taiwan. This study is to evaluate how chlorine dioxide (ClO2) to replace sodium hypochlorite. The high-purity chlorine dioxide was produced via a chemical reaction by sodium chlorite and hydrochloric acid reacted. Continuous monitoring and data recording all the time during the trial for water quality, metal pipe line and inside copper pipe of chiller corrosion rate before and after dosing chlorine dioxide. Finally, we are about to evaluate the operation economical benefits via comparisons of cooling towers supply water addition rate and approach temperature variations. The result indicated that high-purity chlorine dioxide is an extremely effective disinfectant; the total bacterial count in the cooling towers is decreased to the level of 5.0Î102 CFU/mL, chiller’s approach temperature is improved and dropped more than 1 ℃ in average. Also it is achieved and saved more than NT$ 1 million/year cost compared to current trial run plant on site. Huang, Chih-Pin 黃志彬 2013 學位論文 ; thesis 73 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立交通大學 === 工學院永續環境科技學程 === 101 === The chiller has always been the most powerful consumption operation unit among the factories. One of the most important parameter to remain the chiller operation efficiency is the approach temperature. During the operation, circulating water through cooling towers for heat exchanged is needed, therefore it has become the significantly important to keep good water quality by cooling tower, particularly the total bacterial count. Bacteria growth has become biofilm attached inside copper pipe within heat exchange unit, it will cause not only additional power consumption but also pipe corrosion. Conventionally, sodium hypochlorite (NaOCl) is the mostly used for disinfectants to water treatment since it’s very cheap and easy to access, however, we are short of the research of cooling tower operation by chlorine dioxide in Taiwan. This study is to evaluate how chlorine dioxide (ClO2) to replace sodium hypochlorite. The high-purity chlorine dioxide was produced via a chemical reaction by sodium chlorite and hydrochloric acid reacted. Continuous monitoring and data recording all the time during the trial for water quality, metal pipe line and inside copper pipe of chiller corrosion rate before and after dosing chlorine dioxide. Finally, we are about to evaluate the operation economical benefits via comparisons of cooling towers supply water addition rate and approach temperature variations. The result indicated that high-purity chlorine dioxide is an extremely effective disinfectant; the total bacterial count in the cooling towers is decreased to the level of 5.0Î102 CFU/mL, chiller’s approach temperature is improved and dropped more than 1 ℃ in average. Also it is achieved and saved more than NT$ 1 million/year cost compared to current trial run plant on site.
author2 Huang, Chih-Pin
author_facet Huang, Chih-Pin
Chou, Wen-Cheng
周文朕
author Chou, Wen-Cheng
周文朕
spellingShingle Chou, Wen-Cheng
周文朕
Disinfection in Cooling Tower by Chlorine Dioxide:Performance Evaluation
author_sort Chou, Wen-Cheng
title Disinfection in Cooling Tower by Chlorine Dioxide:Performance Evaluation
title_short Disinfection in Cooling Tower by Chlorine Dioxide:Performance Evaluation
title_full Disinfection in Cooling Tower by Chlorine Dioxide:Performance Evaluation
title_fullStr Disinfection in Cooling Tower by Chlorine Dioxide:Performance Evaluation
title_full_unstemmed Disinfection in Cooling Tower by Chlorine Dioxide:Performance Evaluation
title_sort disinfection in cooling tower by chlorine dioxide:performance evaluation
publishDate 2013
url http://ndltd.ncl.edu.tw/handle/c8zdu5
work_keys_str_mv AT chouwencheng disinfectionincoolingtowerbychlorinedioxideperformanceevaluation
AT zhōuwénzhèn disinfectionincoolingtowerbychlorinedioxideperformanceevaluation
AT chouwencheng èryǎnghuàlǜshājūnxiàonéngyīngyòngyúlěngquèshuǐtǎzhīshíchǎngpínggū
AT zhōuwénzhèn èryǎnghuàlǜshājūnxiàonéngyīngyòngyúlěngquèshuǐtǎzhīshíchǎngpínggū
_version_ 1719109212321087488