Application of Displacement Frequency Response Function in Building Structural Health Monitoring

碩士 === 國立交通大學 === 土木工程學系 === 101 === Recently, non-contact measurement technique has received considerable interest that provides accurate measurements of the full field strain distribution, and the process of the approach is simple. This study proposes a structural health monitoring (SHM) system wh...

Full description

Bibliographic Details
Main Authors: Chen, Xuan-Zhi, 陳宣治
Other Authors: Hung, Shih-Lin
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/71508928612478109672
id ndltd-TW-101NCTU5015044
record_format oai_dc
spelling ndltd-TW-101NCTU50150442016-07-02T04:20:16Z http://ndltd.ncl.edu.tw/handle/71508928612478109672 Application of Displacement Frequency Response Function in Building Structural Health Monitoring 位移頻率響應函數於房屋結構健康監測之應用 Chen, Xuan-Zhi 陳宣治 碩士 國立交通大學 土木工程學系 101 Recently, non-contact measurement technique has received considerable interest that provides accurate measurements of the full field strain distribution, and the process of the approach is simple. This study proposes a structural health monitoring (SHM) system which combined DIC method and a displacement-based structural frequency response function (FRF) analysis method. The system includes three sub-systems, image processing, and numerical simulation analysis and damage diagnosis. A numerical study is first employed to evaluate the validation and performance of the proposed system. An eight-story steel structure was then used as an experiment modal and examined on NCREE via DIC technique to detect the simulated damage of steel frame. Also, a modified curvature of sub-structure FRF (subFRF) approach is developed to detect damage location of structures. In experiment, the index of subFRF is used for evaluation and identification of the damage location. The results from different approaches and data acquisition methods are compared in order to demonstrate the applicability of sub-structure FRF method to structural health monitoring. The simulation and experiment results reveal that the modified subFRF curvature method is more sensitive in experiment than numerical simulations. Also, simulation results indicate that this method has better performance on the discontinuous damage locations of damage cases, but encounter continuous positions would not be able to do the correct judgment. Hung, Shih-Lin 洪士林 2012 學位論文 ; thesis 114 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立交通大學 === 土木工程學系 === 101 === Recently, non-contact measurement technique has received considerable interest that provides accurate measurements of the full field strain distribution, and the process of the approach is simple. This study proposes a structural health monitoring (SHM) system which combined DIC method and a displacement-based structural frequency response function (FRF) analysis method. The system includes three sub-systems, image processing, and numerical simulation analysis and damage diagnosis. A numerical study is first employed to evaluate the validation and performance of the proposed system. An eight-story steel structure was then used as an experiment modal and examined on NCREE via DIC technique to detect the simulated damage of steel frame. Also, a modified curvature of sub-structure FRF (subFRF) approach is developed to detect damage location of structures. In experiment, the index of subFRF is used for evaluation and identification of the damage location. The results from different approaches and data acquisition methods are compared in order to demonstrate the applicability of sub-structure FRF method to structural health monitoring. The simulation and experiment results reveal that the modified subFRF curvature method is more sensitive in experiment than numerical simulations. Also, simulation results indicate that this method has better performance on the discontinuous damage locations of damage cases, but encounter continuous positions would not be able to do the correct judgment.
author2 Hung, Shih-Lin
author_facet Hung, Shih-Lin
Chen, Xuan-Zhi
陳宣治
author Chen, Xuan-Zhi
陳宣治
spellingShingle Chen, Xuan-Zhi
陳宣治
Application of Displacement Frequency Response Function in Building Structural Health Monitoring
author_sort Chen, Xuan-Zhi
title Application of Displacement Frequency Response Function in Building Structural Health Monitoring
title_short Application of Displacement Frequency Response Function in Building Structural Health Monitoring
title_full Application of Displacement Frequency Response Function in Building Structural Health Monitoring
title_fullStr Application of Displacement Frequency Response Function in Building Structural Health Monitoring
title_full_unstemmed Application of Displacement Frequency Response Function in Building Structural Health Monitoring
title_sort application of displacement frequency response function in building structural health monitoring
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/71508928612478109672
work_keys_str_mv AT chenxuanzhi applicationofdisplacementfrequencyresponsefunctioninbuildingstructuralhealthmonitoring
AT chénxuānzhì applicationofdisplacementfrequencyresponsefunctioninbuildingstructuralhealthmonitoring
AT chenxuanzhi wèiyípínlǜxiǎngyīnghánshùyúfángwūjiégòujiànkāngjiāncèzhīyīngyòng
AT chénxuānzhì wèiyípínlǜxiǎngyīnghánshùyúfángwūjiégòujiànkāngjiāncèzhīyīngyòng
_version_ 1718331426419507200