Placement of Phasor Measurement Units (PMU) against FalseData Injection Attacks

碩士 === 國立成功大學 === 工程科學系碩博士班 === 101 === A power grid is a large and complex system. To ensure a reliable operation, control center must use state estimation to monitor the state of the system at any time. In recent years, a new type of synchronous phasor measurement unit (PMU) is developed to replac...

Full description

Bibliographic Details
Main Authors: Ko-WeiHsieh, 謝克韡
Other Authors: Wen-Long Chin
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/36059782586446666001
id ndltd-TW-101NCKU5028104
record_format oai_dc
spelling ndltd-TW-101NCKU50281042015-10-13T22:51:44Z http://ndltd.ncl.edu.tw/handle/36059782586446666001 Placement of Phasor Measurement Units (PMU) against FalseData Injection Attacks 針對假數據注入攻擊的PMU最佳擺設方式 Ko-WeiHsieh 謝克韡 碩士 國立成功大學 工程科學系碩博士班 101 A power grid is a large and complex system. To ensure a reliable operation, control center must use state estimation to monitor the state of the system at any time. In recent years, a new type of synchronous phasor measurement unit (PMU) is developed to replace the traditional measurement meter based on the power flow. The PMU can calculate the state of the system more quickly and accurately. It will bring a significant impact on monitoring, control, and protection of the power system. Recently, Liu et al.[1] proposed a new attack which can compromise the existing bad data detection system and arbitrarily manipulate the states of power system. To prevent such an attack, this paper proposed a new algorithm to find the best placement of PMUs. We consider two kinds of attacks, i.e. random false data injection attack and targeted false data injection attack. We verify the proposed algorithm using IEEE 14-bus and 30-bus[2]. Wen-Long Chin 卿文龍 2013 學位論文 ; thesis 67 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立成功大學 === 工程科學系碩博士班 === 101 === A power grid is a large and complex system. To ensure a reliable operation, control center must use state estimation to monitor the state of the system at any time. In recent years, a new type of synchronous phasor measurement unit (PMU) is developed to replace the traditional measurement meter based on the power flow. The PMU can calculate the state of the system more quickly and accurately. It will bring a significant impact on monitoring, control, and protection of the power system. Recently, Liu et al.[1] proposed a new attack which can compromise the existing bad data detection system and arbitrarily manipulate the states of power system. To prevent such an attack, this paper proposed a new algorithm to find the best placement of PMUs. We consider two kinds of attacks, i.e. random false data injection attack and targeted false data injection attack. We verify the proposed algorithm using IEEE 14-bus and 30-bus[2].
author2 Wen-Long Chin
author_facet Wen-Long Chin
Ko-WeiHsieh
謝克韡
author Ko-WeiHsieh
謝克韡
spellingShingle Ko-WeiHsieh
謝克韡
Placement of Phasor Measurement Units (PMU) against FalseData Injection Attacks
author_sort Ko-WeiHsieh
title Placement of Phasor Measurement Units (PMU) against FalseData Injection Attacks
title_short Placement of Phasor Measurement Units (PMU) against FalseData Injection Attacks
title_full Placement of Phasor Measurement Units (PMU) against FalseData Injection Attacks
title_fullStr Placement of Phasor Measurement Units (PMU) against FalseData Injection Attacks
title_full_unstemmed Placement of Phasor Measurement Units (PMU) against FalseData Injection Attacks
title_sort placement of phasor measurement units (pmu) against falsedata injection attacks
publishDate 2013
url http://ndltd.ncl.edu.tw/handle/36059782586446666001
work_keys_str_mv AT koweihsieh placementofphasormeasurementunitspmuagainstfalsedatainjectionattacks
AT xièkèwěi placementofphasormeasurementunitspmuagainstfalsedatainjectionattacks
AT koweihsieh zhēnduìjiǎshùjùzhùrùgōngjīdepmuzuìjiābǎishèfāngshì
AT xièkèwěi zhēnduìjiǎshùjùzhùrùgōngjīdepmuzuìjiābǎishèfāngshì
_version_ 1718080572328247296