The Evaluation of the Affecting Factors on the Pulse Oximeter

碩士 === 國立中興大學 === 生物產業機電工程學系所 === 101 === Oxygen saturation is an important indicator to observe the phenomenon of human life in modern diagnosis currently, and the major tools for measuring oxygen saturation is the non-invasive optical detection of pulse oximeters. The non-invasive optical detecti...

Full description

Bibliographic Details
Main Authors: Ming-Yi Chen, 陳明毅
Other Authors: Chia-Chung Chen
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/29394928857351101559
id ndltd-TW-101NCHU5415009
record_format oai_dc
spelling ndltd-TW-101NCHU54150092016-11-06T04:19:16Z http://ndltd.ncl.edu.tw/handle/29394928857351101559 The Evaluation of the Affecting Factors on the Pulse Oximeter 脈衝式血氧濃度計影響因子之評估 Ming-Yi Chen 陳明毅 碩士 國立中興大學 生物產業機電工程學系所 101 Oxygen saturation is an important indicator to observe the phenomenon of human life in modern diagnosis currently, and the major tools for measuring oxygen saturation is the non-invasive optical detection of pulse oximeters. The non-invasive optical detection could be affected by various influence factors, such as ambient light, nail polish, dyshemoglobins et al. These factors may interference the oxygen saturation value and increase the uncertainty of measurement. In this approach, two different pulse oximeters were used the nail polish and ambient light were the factors of different experimental methods. Statistical tests for pulse oximeters to the influence of outside environment and were applied. Measurements in noisy environments may cause the degree of error. In this study the ambient light interference showed insignificant. However, this result may be related to light intensity disturbance and instrument design. Nail polish interference is a significant factor in this study. The specific error was caused by different color. Black, dark green, blue Nail polish all might cause large errors. The experimental results are available only for limited the following devices: NONIN pulse oximeters tabletop type 9600, handheld type 2500 and Finger clip probes. Chia-Chung Chen 陳加忠 2013 學位論文 ; thesis 88 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中興大學 === 生物產業機電工程學系所 === 101 === Oxygen saturation is an important indicator to observe the phenomenon of human life in modern diagnosis currently, and the major tools for measuring oxygen saturation is the non-invasive optical detection of pulse oximeters. The non-invasive optical detection could be affected by various influence factors, such as ambient light, nail polish, dyshemoglobins et al. These factors may interference the oxygen saturation value and increase the uncertainty of measurement. In this approach, two different pulse oximeters were used the nail polish and ambient light were the factors of different experimental methods. Statistical tests for pulse oximeters to the influence of outside environment and were applied. Measurements in noisy environments may cause the degree of error. In this study the ambient light interference showed insignificant. However, this result may be related to light intensity disturbance and instrument design. Nail polish interference is a significant factor in this study. The specific error was caused by different color. Black, dark green, blue Nail polish all might cause large errors. The experimental results are available only for limited the following devices: NONIN pulse oximeters tabletop type 9600, handheld type 2500 and Finger clip probes.
author2 Chia-Chung Chen
author_facet Chia-Chung Chen
Ming-Yi Chen
陳明毅
author Ming-Yi Chen
陳明毅
spellingShingle Ming-Yi Chen
陳明毅
The Evaluation of the Affecting Factors on the Pulse Oximeter
author_sort Ming-Yi Chen
title The Evaluation of the Affecting Factors on the Pulse Oximeter
title_short The Evaluation of the Affecting Factors on the Pulse Oximeter
title_full The Evaluation of the Affecting Factors on the Pulse Oximeter
title_fullStr The Evaluation of the Affecting Factors on the Pulse Oximeter
title_full_unstemmed The Evaluation of the Affecting Factors on the Pulse Oximeter
title_sort evaluation of the affecting factors on the pulse oximeter
publishDate 2013
url http://ndltd.ncl.edu.tw/handle/29394928857351101559
work_keys_str_mv AT mingyichen theevaluationoftheaffectingfactorsonthepulseoximeter
AT chénmíngyì theevaluationoftheaffectingfactorsonthepulseoximeter
AT mingyichen màichōngshìxuèyǎngnóngdùjìyǐngxiǎngyīnzizhīpínggū
AT chénmíngyì màichōngshìxuèyǎngnóngdùjìyǐngxiǎngyīnzizhīpínggū
AT mingyichen evaluationoftheaffectingfactorsonthepulseoximeter
AT chénmíngyì evaluationoftheaffectingfactorsonthepulseoximeter
_version_ 1718390990447837184