Performance Analysis Of Fixed c-Si PV Modules With The Optimum Tilt And Azimuth Angles For Electric Peak Load In Taiwan
碩士 === 國立高雄應用科技大學 === 應用工程科學研究所 === 101 === During the process about energy of Sun was transformed into electric power directly by the photovoltaic, it is fewer to pollute the environment and so be considered the main choices instead of fossil fuel for future. But the photovoltaic can not keep gener...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
102
|
Online Access: | http://ndltd.ncl.edu.tw/handle/84213968219555240620 |
id |
ndltd-TW-101KUAS8028003 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-101KUAS80280032016-05-04T04:31:50Z http://ndltd.ncl.edu.tw/handle/84213968219555240620 Performance Analysis Of Fixed c-Si PV Modules With The Optimum Tilt And Azimuth Angles For Electric Peak Load In Taiwan 台灣電力尖峰負載下固定式晶矽太陽電池模組最佳方位角及傾斜角之發電效益 TienPao Fu 傅添保 碩士 國立高雄應用科技大學 應用工程科學研究所 101 During the process about energy of Sun was transformed into electric power directly by the photovoltaic, it is fewer to pollute the environment and so be considered the main choices instead of fossil fuel for future. But the photovoltaic can not keep generating electric power stably and detain its development because it is easy to be effected by the weather. How to using the sunlight efficiently to promote the electric power of the photovoltaic when the hot weather cause power load gaining extremely is a worth researched direction. The research bases on the characteristic of Taiwan power load and using its recent-year system load data to conclude peak load time. It will decide tilt angle and azimuth angle when install its photovoltaic, this way will gain the maximum electric power to approve the ability of supplement of photovoltaic for the peak load to reducing the low-efficient reserve margin. Dedicating to strengthen the present stage of photovoltaic power system becomes a role of alternative energy. The experiment shows that it can boost the c-Si photovoltaic to generate electric power about 19% to 43% when using at peak load time to decide the tilt angle and azimuth angle of fixed- c-Si photovoltaic, that generating electric power will match the peak demand of Taiwanese power load and is different when comparing of the installation which using by latitude to decide the tilt angle and azimuth angle. Herchang Ay 艾和昌 102 學位論文 ; thesis 70 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立高雄應用科技大學 === 應用工程科學研究所 === 101 === During the process about energy of Sun was transformed into electric power directly by the photovoltaic, it is fewer to pollute the environment and so be considered the main choices instead of fossil fuel for future. But the photovoltaic can not keep generating electric power stably and detain its development because it is easy to be effected by the weather. How to using the sunlight efficiently to promote the electric power of the photovoltaic when the hot weather cause power load gaining extremely is a worth researched direction.
The research bases on the characteristic of Taiwan power load and using its recent-year system load data to conclude peak load time. It will decide tilt angle and azimuth angle when install its photovoltaic, this way will gain the maximum electric power to approve the ability of supplement of photovoltaic for the peak load to reducing the low-efficient reserve margin. Dedicating to strengthen the present stage of photovoltaic power system becomes a role of alternative energy. The experiment shows that it can boost the c-Si photovoltaic to generate electric power about 19% to 43% when using at peak load time to decide the tilt angle and azimuth angle of fixed- c-Si photovoltaic, that generating electric power will match the peak demand of Taiwanese power load and is different when comparing of the installation which using by latitude to decide the tilt angle and azimuth angle.
|
author2 |
Herchang Ay |
author_facet |
Herchang Ay TienPao Fu 傅添保 |
author |
TienPao Fu 傅添保 |
spellingShingle |
TienPao Fu 傅添保 Performance Analysis Of Fixed c-Si PV Modules With The Optimum Tilt And Azimuth Angles For Electric Peak Load In Taiwan |
author_sort |
TienPao Fu |
title |
Performance Analysis Of Fixed c-Si PV Modules With The Optimum Tilt And Azimuth Angles For Electric Peak Load In Taiwan |
title_short |
Performance Analysis Of Fixed c-Si PV Modules With The Optimum Tilt And Azimuth Angles For Electric Peak Load In Taiwan |
title_full |
Performance Analysis Of Fixed c-Si PV Modules With The Optimum Tilt And Azimuth Angles For Electric Peak Load In Taiwan |
title_fullStr |
Performance Analysis Of Fixed c-Si PV Modules With The Optimum Tilt And Azimuth Angles For Electric Peak Load In Taiwan |
title_full_unstemmed |
Performance Analysis Of Fixed c-Si PV Modules With The Optimum Tilt And Azimuth Angles For Electric Peak Load In Taiwan |
title_sort |
performance analysis of fixed c-si pv modules with the optimum tilt and azimuth angles for electric peak load in taiwan |
publishDate |
102 |
url |
http://ndltd.ncl.edu.tw/handle/84213968219555240620 |
work_keys_str_mv |
AT tienpaofu performanceanalysisoffixedcsipvmoduleswiththeoptimumtiltandazimuthanglesforelectricpeakloadintaiwan AT fùtiānbǎo performanceanalysisoffixedcsipvmoduleswiththeoptimumtiltandazimuthanglesforelectricpeakloadintaiwan AT tienpaofu táiwāndiànlìjiānfēngfùzàixiàgùdìngshìjīngxìtàiyángdiànchímózǔzuìjiāfāngwèijiǎojíqīngxiéjiǎozhīfādiànxiàoyì AT fùtiānbǎo táiwāndiànlìjiānfēngfùzàixiàgùdìngshìjīngxìtàiyángdiànchímózǔzuìjiāfāngwèijiǎojíqīngxiéjiǎozhīfādiànxiàoyì |
_version_ |
1718260304970776576 |