碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 101 === CBCT images had become more and more essential technique in Radiation oncology. Image quality and relative dose of CBCT had been more and more concerned. This study used Taguchi method to optimize the operative parameters in CBCT to achieve better image f...

Full description

Bibliographic Details
Main Authors: Liu, Fang-Hui, 劉芳慧
Other Authors: Pan, Lung-Kwang
Format: Others
Language:zh-TW
Published: 2013
Online Access:http://ndltd.ncl.edu.tw/handle/02395341977494247086
id ndltd-TW-101CTC07770010
record_format oai_dc
spelling ndltd-TW-101CTC077700102016-05-22T04:32:53Z http://ndltd.ncl.edu.tw/handle/02395341977494247086 Optimization the Cone-Beam CT parameters via Taguchi Methodology 利用田口最佳化評量錐形射束電腦斷層影像品質條件 Liu, Fang-Hui 劉芳慧 碩士 中臺科技大學 醫學影像暨放射科學系暨研究所 101 CBCT images had become more and more essential technique in Radiation oncology. Image quality and relative dose of CBCT had been more and more concerned. This study used Taguchi method to optimize the operative parameters in CBCT to achieve better image from practical viewpoint. The Catphan 504 phantom was adopted in this work because of either Teflon or Acrylic had similar HU response to bone and tissue in the real examination and a higher CNR was the optimized recommendation. The recommended combination of CBCT operative parameters was further verified by inspecting the accompanied exposed dose to comply with the ALARA principle. The optimized parameters setting were 27.2*20.6 of FOV, 20*10 of mAs, 720 No. of Projection, 256*256 No. of pixel, 3 of Slice thickness.smooth of Reconstruction filter and weak of Ring Artifact Suppression. The evaluated results were verified from the ANOVA test in this work. The optimal setting had superior to original one in either CNR or lower dose. Using Taguchi method not only minimized the experimental frequencies but also lowered the exposed dose in real examination process. Pan, Lung-Kwang 潘榕光 2013 學位論文 ; thesis 65 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中臺科技大學 === 醫學影像暨放射科學系暨研究所 === 101 === CBCT images had become more and more essential technique in Radiation oncology. Image quality and relative dose of CBCT had been more and more concerned. This study used Taguchi method to optimize the operative parameters in CBCT to achieve better image from practical viewpoint. The Catphan 504 phantom was adopted in this work because of either Teflon or Acrylic had similar HU response to bone and tissue in the real examination and a higher CNR was the optimized recommendation. The recommended combination of CBCT operative parameters was further verified by inspecting the accompanied exposed dose to comply with the ALARA principle. The optimized parameters setting were 27.2*20.6 of FOV, 20*10 of mAs, 720 No. of Projection, 256*256 No. of pixel, 3 of Slice thickness.smooth of Reconstruction filter and weak of Ring Artifact Suppression. The evaluated results were verified from the ANOVA test in this work. The optimal setting had superior to original one in either CNR or lower dose. Using Taguchi method not only minimized the experimental frequencies but also lowered the exposed dose in real examination process.
author2 Pan, Lung-Kwang
author_facet Pan, Lung-Kwang
Liu, Fang-Hui
劉芳慧
author Liu, Fang-Hui
劉芳慧
spellingShingle Liu, Fang-Hui
劉芳慧
Optimization the Cone-Beam CT parameters via Taguchi Methodology
author_sort Liu, Fang-Hui
title Optimization the Cone-Beam CT parameters via Taguchi Methodology
title_short Optimization the Cone-Beam CT parameters via Taguchi Methodology
title_full Optimization the Cone-Beam CT parameters via Taguchi Methodology
title_fullStr Optimization the Cone-Beam CT parameters via Taguchi Methodology
title_full_unstemmed Optimization the Cone-Beam CT parameters via Taguchi Methodology
title_sort optimization the cone-beam ct parameters via taguchi methodology
publishDate 2013
url http://ndltd.ncl.edu.tw/handle/02395341977494247086
work_keys_str_mv AT liufanghui optimizationtheconebeamctparametersviataguchimethodology
AT liúfānghuì optimizationtheconebeamctparametersviataguchimethodology
AT liufanghui lìyòngtiánkǒuzuìjiāhuàpíngliàngzhuīxíngshèshùdiànnǎoduàncéngyǐngxiàngpǐnzhìtiáojiàn
AT liúfānghuì lìyòngtiánkǒuzuìjiāhuàpíngliàngzhuīxíngshèshùdiànnǎoduàncéngyǐngxiàngpǐnzhìtiáojiàn
_version_ 1718274236618899456