A Study on the Effect of Cryogenic Treatment Electrodes for EDM Coke

碩士 === 中州科技大學 === 工程技術研究所 === 101 === ABSTRACT The EDM electrode coke confuses the industry and researchers for a long time. So the copper electrodes after cryogenic treatment were introduced by this research. The relationship of electrode coke and EDMed parameters of polarity, duration time, dis...

Full description

Bibliographic Details
Main Authors: Chen Dung Yan, 陳東演
Other Authors: Huang.Li-Ren
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/10781911354622919634
id ndltd-TW-101CCUT7027014
record_format oai_dc
spelling ndltd-TW-101CCUT70270142016-12-25T04:10:44Z http://ndltd.ncl.edu.tw/handle/10781911354622919634 A Study on the Effect of Cryogenic Treatment Electrodes for EDM Coke 超冷處理對放電加工後電極積碳影響之研究 Chen Dung Yan 陳東演 碩士 中州科技大學 工程技術研究所 101 ABSTRACT The EDM electrode coke confuses the industry and researchers for a long time. So the copper electrodes after cryogenic treatment were introduced by this research. The relationship of electrode coke and EDMed parameters of polarity, duration time, discharge gap distance, high-voltage current, and low-voltage current of electrical discharge machining (EDM) were mainly processing parameters with powder metallurgical sintered alloy steel in this study. The experimental results explored material removal rate (MRR), electrode wear rate (EWR), workpiece and electrode surface roughness highly relates processing parameters. Therefore, the statistical method and the contribution of relation with EDMed sintered alloy steel by Taguchi method of orthogonal array planning experiments. Analysis of variance by polarity, duration time, discharge gap distance, high-voltage current, and low-voltage current are the main processing parameters. Reduced electrode coke by ANOVA were negative polarity, 100 s duration time, 8 % discharge gap distance, 3 amp high-voltage current, and 1 amp low-voltage current. Keywords: EDM, Cryogenic treatment, Taguchi method Huang.Li-Ren 黃立仁 2012 學位論文 ; thesis 66 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 中州科技大學 === 工程技術研究所 === 101 === ABSTRACT The EDM electrode coke confuses the industry and researchers for a long time. So the copper electrodes after cryogenic treatment were introduced by this research. The relationship of electrode coke and EDMed parameters of polarity, duration time, discharge gap distance, high-voltage current, and low-voltage current of electrical discharge machining (EDM) were mainly processing parameters with powder metallurgical sintered alloy steel in this study. The experimental results explored material removal rate (MRR), electrode wear rate (EWR), workpiece and electrode surface roughness highly relates processing parameters. Therefore, the statistical method and the contribution of relation with EDMed sintered alloy steel by Taguchi method of orthogonal array planning experiments. Analysis of variance by polarity, duration time, discharge gap distance, high-voltage current, and low-voltage current are the main processing parameters. Reduced electrode coke by ANOVA were negative polarity, 100 s duration time, 8 % discharge gap distance, 3 amp high-voltage current, and 1 amp low-voltage current. Keywords: EDM, Cryogenic treatment, Taguchi method
author2 Huang.Li-Ren
author_facet Huang.Li-Ren
Chen Dung Yan
陳東演
author Chen Dung Yan
陳東演
spellingShingle Chen Dung Yan
陳東演
A Study on the Effect of Cryogenic Treatment Electrodes for EDM Coke
author_sort Chen Dung Yan
title A Study on the Effect of Cryogenic Treatment Electrodes for EDM Coke
title_short A Study on the Effect of Cryogenic Treatment Electrodes for EDM Coke
title_full A Study on the Effect of Cryogenic Treatment Electrodes for EDM Coke
title_fullStr A Study on the Effect of Cryogenic Treatment Electrodes for EDM Coke
title_full_unstemmed A Study on the Effect of Cryogenic Treatment Electrodes for EDM Coke
title_sort study on the effect of cryogenic treatment electrodes for edm coke
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/10781911354622919634
work_keys_str_mv AT chendungyan astudyontheeffectofcryogenictreatmentelectrodesforedmcoke
AT chéndōngyǎn astudyontheeffectofcryogenictreatmentelectrodesforedmcoke
AT chendungyan chāolěngchùlǐduìfàngdiànjiāgōnghòudiànjíjītànyǐngxiǎngzhīyánjiū
AT chéndōngyǎn chāolěngchùlǐduìfàngdiànjiāgōnghòudiànjíjītànyǐngxiǎngzhīyánjiū
AT chendungyan studyontheeffectofcryogenictreatmentelectrodesforedmcoke
AT chéndōngyǎn studyontheeffectofcryogenictreatmentelectrodesforedmcoke
_version_ 1718405721681297408