Study of Smooth Transition Among Inverter Operation Modes
碩士 === 國立中正大學 === 電機工程研究所 === 101 === This thesis presents a study of smooth transition among inverter operation modes, including grid connection, rectification and inversion. The inverter system includes battery charging and discharging, power factor correction, harmonic suppression and backup powe...
Main Authors: | , |
---|---|
Other Authors: | |
Format: | Others |
Language: | zh-TW |
Published: |
2013
|
Online Access: | http://ndltd.ncl.edu.tw/handle/59134619545551481598 |
id |
ndltd-TW-101CCU00442042 |
---|---|
record_format |
oai_dc |
spelling |
ndltd-TW-101CCU004420422016-03-23T04:14:22Z http://ndltd.ncl.edu.tw/handle/59134619545551481598 Study of Smooth Transition Among Inverter Operation Modes 換流器操作模式平滑些換研究 Tsai, Ren-Jie 蔡人傑 碩士 國立中正大學 電機工程研究所 101 This thesis presents a study of smooth transition among inverter operation modes, including grid connection, rectification and inversion. The inverter system includes battery charging and discharging, power factor correction, harmonic suppression and backup power. In grid-connection mode, the inverter will inject real power to the utility grid. In rectification mode, the inverter will charge battery. When utility grid fails, the inverter can transit seamlessly from grid-connection mode to inversion mode. The battery can deliver power through the inverter to supply the load continuously and regulate the voltage. Finally, the inverter has been built and tested, and simulated and experimental results have verified the proposed control scheme and feasibility of the system. Wu, Tsai-Fu Yu, Gwo-Ruey 吳財福 余國瑞 2013 學位論文 ; thesis 85 zh-TW |
collection |
NDLTD |
language |
zh-TW |
format |
Others
|
sources |
NDLTD |
description |
碩士 === 國立中正大學 === 電機工程研究所 === 101 === This thesis presents a study of smooth transition among inverter operation modes, including grid connection, rectification and inversion. The inverter system includes battery charging and discharging, power factor correction, harmonic suppression and backup power. In grid-connection mode, the inverter will inject real power to the utility grid. In rectification mode, the inverter will charge battery. When utility grid fails, the inverter can transit seamlessly from grid-connection mode to inversion mode. The battery can deliver power through the inverter to supply the load continuously and regulate the voltage. Finally, the inverter has been built and tested, and simulated and experimental results have verified the proposed control scheme and feasibility of the system.
|
author2 |
Wu, Tsai-Fu |
author_facet |
Wu, Tsai-Fu Tsai, Ren-Jie 蔡人傑 |
author |
Tsai, Ren-Jie 蔡人傑 |
spellingShingle |
Tsai, Ren-Jie 蔡人傑 Study of Smooth Transition Among Inverter Operation Modes |
author_sort |
Tsai, Ren-Jie |
title |
Study of Smooth Transition Among Inverter Operation Modes |
title_short |
Study of Smooth Transition Among Inverter Operation Modes |
title_full |
Study of Smooth Transition Among Inverter Operation Modes |
title_fullStr |
Study of Smooth Transition Among Inverter Operation Modes |
title_full_unstemmed |
Study of Smooth Transition Among Inverter Operation Modes |
title_sort |
study of smooth transition among inverter operation modes |
publishDate |
2013 |
url |
http://ndltd.ncl.edu.tw/handle/59134619545551481598 |
work_keys_str_mv |
AT tsairenjie studyofsmoothtransitionamonginverteroperationmodes AT càirénjié studyofsmoothtransitionamonginverteroperationmodes AT tsairenjie huànliúqìcāozuòmóshìpínghuáxiēhuànyánjiū AT càirénjié huànliúqìcāozuòmóshìpínghuáxiēhuànyánjiū |
_version_ |
1718211398658424832 |