Finite Element Evaluation for Lumbar Disc Prostheses with the Application of Compressive-Shearing Test Method

碩士 === 國立陽明大學 === 醫學工程研究所 === 100 === Security verifications with international testing standards before marketing are essential for orthopaedic implants. Lumbar disc prosthesis, as a non-fusion implant for treatment of degenerated lumbar intervertebral disc, has met the basic biomechanical requirem...

Full description

Bibliographic Details
Main Authors: Jou-Wen Chen, 陳柔文
Other Authors: Cheng-Kung Cheng
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/90102317864924938253
id ndltd-TW-100YM005530023
record_format oai_dc
spelling ndltd-TW-100YM0055300232015-10-13T21:22:39Z http://ndltd.ncl.edu.tw/handle/90102317864924938253 Finite Element Evaluation for Lumbar Disc Prostheses with the Application of Compressive-Shearing Test Method 應用改良型壓剪測試於腰椎人工椎間盤評估之有限元素分析研究 Jou-Wen Chen 陳柔文 碩士 國立陽明大學 醫學工程研究所 100 Security verifications with international testing standards before marketing are essential for orthopaedic implants. Lumbar disc prosthesis, as a non-fusion implant for treatment of degenerated lumbar intervertebral disc, has met the basic biomechanical requirements through the examination with ASTM F-2646. It has been claimed that the defined testing conditions in ASTM standard cannot include all the possible situations after implantation, thus failures of disc prostheses in clinical practice may be the evidences that the current testing method may be a perfect way. A modified compressive-shearing test (MCS test), based on ASTM standard, has been developed utilized for evaluating the security of polyethylene (PE) component in disc prosthesis. However, loading conditions in the MCS test have not been completely evaluated, neither has the comparison between the MCS test and ASTM standard been performed. Purpose of current study was to accomplish a more completed finite element evaluation to the MCS test method with 2 commercial lumbar disc prostheses, and also compared with traditional ASTM standard testing method to confirm the differences between the methods. The values and distributions of von Mises stresses on PE components were considered as the main mechanical parameter for evaluation. Results revealed that, lower resultant force was required for PE component failure in the MCS test method than the ASTM standard testing method. With the application of MCS test method, the mechanical safe zones can be respectively defined for the different prosthetic disc designs. Current study has accomplished more detailed evaluations of the MCS test method, and represented that the mechanical failure of PE component in lumbar disc prosthesis can be more conservatively evaluated using the MCS test method than the ASTM standard testing method. The MCS test method can be beneficial for future lumbar disc prosthesis in the early stage of its designing process. Cheng-Kung Cheng 鄭誠功 2012 學位論文 ; thesis 75 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立陽明大學 === 醫學工程研究所 === 100 === Security verifications with international testing standards before marketing are essential for orthopaedic implants. Lumbar disc prosthesis, as a non-fusion implant for treatment of degenerated lumbar intervertebral disc, has met the basic biomechanical requirements through the examination with ASTM F-2646. It has been claimed that the defined testing conditions in ASTM standard cannot include all the possible situations after implantation, thus failures of disc prostheses in clinical practice may be the evidences that the current testing method may be a perfect way. A modified compressive-shearing test (MCS test), based on ASTM standard, has been developed utilized for evaluating the security of polyethylene (PE) component in disc prosthesis. However, loading conditions in the MCS test have not been completely evaluated, neither has the comparison between the MCS test and ASTM standard been performed. Purpose of current study was to accomplish a more completed finite element evaluation to the MCS test method with 2 commercial lumbar disc prostheses, and also compared with traditional ASTM standard testing method to confirm the differences between the methods. The values and distributions of von Mises stresses on PE components were considered as the main mechanical parameter for evaluation. Results revealed that, lower resultant force was required for PE component failure in the MCS test method than the ASTM standard testing method. With the application of MCS test method, the mechanical safe zones can be respectively defined for the different prosthetic disc designs. Current study has accomplished more detailed evaluations of the MCS test method, and represented that the mechanical failure of PE component in lumbar disc prosthesis can be more conservatively evaluated using the MCS test method than the ASTM standard testing method. The MCS test method can be beneficial for future lumbar disc prosthesis in the early stage of its designing process.
author2 Cheng-Kung Cheng
author_facet Cheng-Kung Cheng
Jou-Wen Chen
陳柔文
author Jou-Wen Chen
陳柔文
spellingShingle Jou-Wen Chen
陳柔文
Finite Element Evaluation for Lumbar Disc Prostheses with the Application of Compressive-Shearing Test Method
author_sort Jou-Wen Chen
title Finite Element Evaluation for Lumbar Disc Prostheses with the Application of Compressive-Shearing Test Method
title_short Finite Element Evaluation for Lumbar Disc Prostheses with the Application of Compressive-Shearing Test Method
title_full Finite Element Evaluation for Lumbar Disc Prostheses with the Application of Compressive-Shearing Test Method
title_fullStr Finite Element Evaluation for Lumbar Disc Prostheses with the Application of Compressive-Shearing Test Method
title_full_unstemmed Finite Element Evaluation for Lumbar Disc Prostheses with the Application of Compressive-Shearing Test Method
title_sort finite element evaluation for lumbar disc prostheses with the application of compressive-shearing test method
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/90102317864924938253
work_keys_str_mv AT jouwenchen finiteelementevaluationforlumbardiscprostheseswiththeapplicationofcompressiveshearingtestmethod
AT chénróuwén finiteelementevaluationforlumbardiscprostheseswiththeapplicationofcompressiveshearingtestmethod
AT jouwenchen yīngyònggǎiliángxíngyājiǎncèshìyúyāochuíréngōngchuíjiānpánpínggūzhīyǒuxiànyuánsùfēnxīyánjiū
AT chénróuwén yīngyònggǎiliángxíngyājiǎncèshìyúyāochuíréngōngchuíjiānpánpínggūzhīyǒuxiànyuánsùfēnxīyánjiū
_version_ 1718062137006358528