Condensation heat transfer of R-22 and R-410A in U-bend smooth and microfin tubes

碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 100 === This study investigates the condensation heat transfer experiments for two pure refrigerants, R-410A and R-22, in the U-bend smooth and micro-fin tubes. U-bend situated in a vertical plane, including two straight and a bend section. Refrigerants flow fr...

Full description

Bibliographic Details
Main Authors: Cheng-Sheng Liu, 劉政昇
Other Authors: 簡良翰
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/wvz577
id ndltd-TW-100TIT05703036
record_format oai_dc
spelling ndltd-TW-100TIT057030362019-05-15T20:51:53Z http://ndltd.ncl.edu.tw/handle/wvz577 Condensation heat transfer of R-22 and R-410A in U-bend smooth and microfin tubes 冷媒R-22與R-410A在U型平滑與微鰭片管內之冷凝熱傳研究 Cheng-Sheng Liu 劉政昇 碩士 國立臺北科技大學 能源與冷凍空調工程系碩士班 100 This study investigates the condensation heat transfer experiments for two pure refrigerants, R-410A and R-22, in the U-bend smooth and micro-fin tubes. U-bend situated in a vertical plane, including two straight and a bend section. Refrigerants flow from the upper horizontal straight section to the lower horizontal straight section. Experiments were performed at saturation temperatures of 30℃ and 40℃. The mass flux varied from 50 to 200 kg/m2s, and the inlet quality varied from 0.2 to 0.9. The heat transfer rate of the test section was controlled to a decrease of vapor quality of 0.2 in the present experiment. The test results showed that heat transfer coefficient increased as mass flux and quality increased. Condensation heat transfer coefficient of R-22 was higher than R-410A in both the smooth and microfin tubes. The average condensation heat transfer coefficient of the microfin tubes for R-22 and R-410A were 1.63-2.2 and 1.5-1.97 times larger than those of the smooth tube, respectively. In average, the local heat transfer coefficients of R-22 and R-410A in the bend section were, 1.21 and 1.12 times larger than those in the upper straight section, respectively. The maximum local heat transfer coefficient occurs at the midle (90° position) of the bend. Heat transfer correlations of straight horizontal condensation on smooth and microfin tubes predict the data in this study with r.m.s. 9.68% and 5.49% respectively. A correlation of local heat transfer coefficient of the U-bend section based on the straight tube is provided. It predicts the present data of smooth and finned tubes with r.m.s. 9.16% and 5.8%. 簡良翰 2012 學位論文 ; thesis 76 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 能源與冷凍空調工程系碩士班 === 100 === This study investigates the condensation heat transfer experiments for two pure refrigerants, R-410A and R-22, in the U-bend smooth and micro-fin tubes. U-bend situated in a vertical plane, including two straight and a bend section. Refrigerants flow from the upper horizontal straight section to the lower horizontal straight section. Experiments were performed at saturation temperatures of 30℃ and 40℃. The mass flux varied from 50 to 200 kg/m2s, and the inlet quality varied from 0.2 to 0.9. The heat transfer rate of the test section was controlled to a decrease of vapor quality of 0.2 in the present experiment. The test results showed that heat transfer coefficient increased as mass flux and quality increased. Condensation heat transfer coefficient of R-22 was higher than R-410A in both the smooth and microfin tubes. The average condensation heat transfer coefficient of the microfin tubes for R-22 and R-410A were 1.63-2.2 and 1.5-1.97 times larger than those of the smooth tube, respectively. In average, the local heat transfer coefficients of R-22 and R-410A in the bend section were, 1.21 and 1.12 times larger than those in the upper straight section, respectively. The maximum local heat transfer coefficient occurs at the midle (90° position) of the bend. Heat transfer correlations of straight horizontal condensation on smooth and microfin tubes predict the data in this study with r.m.s. 9.68% and 5.49% respectively. A correlation of local heat transfer coefficient of the U-bend section based on the straight tube is provided. It predicts the present data of smooth and finned tubes with r.m.s. 9.16% and 5.8%.
author2 簡良翰
author_facet 簡良翰
Cheng-Sheng Liu
劉政昇
author Cheng-Sheng Liu
劉政昇
spellingShingle Cheng-Sheng Liu
劉政昇
Condensation heat transfer of R-22 and R-410A in U-bend smooth and microfin tubes
author_sort Cheng-Sheng Liu
title Condensation heat transfer of R-22 and R-410A in U-bend smooth and microfin tubes
title_short Condensation heat transfer of R-22 and R-410A in U-bend smooth and microfin tubes
title_full Condensation heat transfer of R-22 and R-410A in U-bend smooth and microfin tubes
title_fullStr Condensation heat transfer of R-22 and R-410A in U-bend smooth and microfin tubes
title_full_unstemmed Condensation heat transfer of R-22 and R-410A in U-bend smooth and microfin tubes
title_sort condensation heat transfer of r-22 and r-410a in u-bend smooth and microfin tubes
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/wvz577
work_keys_str_mv AT chengshengliu condensationheattransferofr22andr410ainubendsmoothandmicrofintubes
AT liúzhèngshēng condensationheattransferofr22andr410ainubendsmoothandmicrofintubes
AT chengshengliu lěngméir22yǔr410azàiuxíngpínghuáyǔwēiqípiànguǎnnèizhīlěngníngrèchuányánjiū
AT liúzhèngshēng lěngméir22yǔr410azàiuxíngpínghuáyǔwēiqípiànguǎnnèizhīlěngníngrèchuányánjiū
_version_ 1719106226559647744