Evaluation for the causes of a femoral neck fracture in hip resurfacing arthroplasty –A finite element study

碩士 === 國立臺北科技大學 === 製造科技研究所 === 100 === With advancements in industrial technologies, resurfacing artificial hip has developed, unlike total hip in the past consumed by unnecessary human bone, the extent of surgery has become a small recovery faster by the medical trend, significant research effort...

Full description

Bibliographic Details
Main Authors: Shou-Hao CHen, 陳首豪
Other Authors: Wenlung Li
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/m8gw44
id ndltd-TW-100TIT05621011
record_format oai_dc
spelling ndltd-TW-100TIT056210112019-05-15T20:51:51Z http://ndltd.ncl.edu.tw/handle/m8gw44 Evaluation for the causes of a femoral neck fracture in hip resurfacing arthroplasty –A finite element study 人工髖關節表面置換術股骨頸骨折預防之研究 Shou-Hao CHen 陳首豪 碩士 國立臺北科技大學 製造科技研究所 100 With advancements in industrial technologies, resurfacing artificial hip has developed, unlike total hip in the past consumed by unnecessary human bone, the extent of surgery has become a small recovery faster by the medical trend, significant research effort has been devoted to total hip resurfacing arthroplasty and clinical trials have been performed in many countries. Thus, the technology is already mature. The increased use of total hip resurfacing arthroplasty is consistent with current trends in medical science. It provides patients with an alternative to total hip arthroplasty. However, clinical trials suggest there are still some issues with total hip resurfacing arthroplasty. Our study analyzes the factors that causes cause failures in the implants, resulting in aseptic loosening and femoral neck fractures. Total hip resurfacing arthroplasty technology is very important for biomechanics, and the implant angle is especially significant. Previous research studies suggest that the implant valgus angle is significant for the overall effectiveness of the total surface replacement artificial hip joint system. Previous studies on implant angles are limited to the 2-D plane, resulting in discrepancies compared to actual surgical conditions. This study also considers the importance of the anteversion angle of the femoral bone in total surface-replacement hip resurfacing arthroplasty. Based on the implant valgus angle, the best implant angle is obtained. Finite element analysis is performed on the location data for scientific verification. This analysis will serve as a reference for clinical surgeons during surgeries. The results of this study suggest that the valgus of an implant does not lead to increased risk of femoral neck fractures. Simulations showed the effect of stress concentration at the bottom of the implant. This may reduce the femoral stress shielding effect, causing failure of the hip replacement. Changes in the nature of different bone will affect the position of maximum stress. When cortical bone and cancellous bone is too large difference, would make the increase in femoral neck stress to fracture risk. This proves that it is possible to cause osteonecrosis will be decline young''s modulus of femoral neck fracture. The anteversion angle is associated with femoral neck section. Choose implant anteversion angle must be to know femoral neck section. In addition, if the valgus angle is greater than 15 degrees, the joint may fail during operation. Thus, we suggest that the suitable valgus angle for the implant is between 5 and 10 degrees. Wenlung Li 黎文龍 2012 學位論文 ; thesis 63 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 製造科技研究所 === 100 === With advancements in industrial technologies, resurfacing artificial hip has developed, unlike total hip in the past consumed by unnecessary human bone, the extent of surgery has become a small recovery faster by the medical trend, significant research effort has been devoted to total hip resurfacing arthroplasty and clinical trials have been performed in many countries. Thus, the technology is already mature. The increased use of total hip resurfacing arthroplasty is consistent with current trends in medical science. It provides patients with an alternative to total hip arthroplasty. However, clinical trials suggest there are still some issues with total hip resurfacing arthroplasty. Our study analyzes the factors that causes cause failures in the implants, resulting in aseptic loosening and femoral neck fractures. Total hip resurfacing arthroplasty technology is very important for biomechanics, and the implant angle is especially significant. Previous research studies suggest that the implant valgus angle is significant for the overall effectiveness of the total surface replacement artificial hip joint system. Previous studies on implant angles are limited to the 2-D plane, resulting in discrepancies compared to actual surgical conditions. This study also considers the importance of the anteversion angle of the femoral bone in total surface-replacement hip resurfacing arthroplasty. Based on the implant valgus angle, the best implant angle is obtained. Finite element analysis is performed on the location data for scientific verification. This analysis will serve as a reference for clinical surgeons during surgeries. The results of this study suggest that the valgus of an implant does not lead to increased risk of femoral neck fractures. Simulations showed the effect of stress concentration at the bottom of the implant. This may reduce the femoral stress shielding effect, causing failure of the hip replacement. Changes in the nature of different bone will affect the position of maximum stress. When cortical bone and cancellous bone is too large difference, would make the increase in femoral neck stress to fracture risk. This proves that it is possible to cause osteonecrosis will be decline young''s modulus of femoral neck fracture. The anteversion angle is associated with femoral neck section. Choose implant anteversion angle must be to know femoral neck section. In addition, if the valgus angle is greater than 15 degrees, the joint may fail during operation. Thus, we suggest that the suitable valgus angle for the implant is between 5 and 10 degrees.
author2 Wenlung Li
author_facet Wenlung Li
Shou-Hao CHen
陳首豪
author Shou-Hao CHen
陳首豪
spellingShingle Shou-Hao CHen
陳首豪
Evaluation for the causes of a femoral neck fracture in hip resurfacing arthroplasty –A finite element study
author_sort Shou-Hao CHen
title Evaluation for the causes of a femoral neck fracture in hip resurfacing arthroplasty –A finite element study
title_short Evaluation for the causes of a femoral neck fracture in hip resurfacing arthroplasty –A finite element study
title_full Evaluation for the causes of a femoral neck fracture in hip resurfacing arthroplasty –A finite element study
title_fullStr Evaluation for the causes of a femoral neck fracture in hip resurfacing arthroplasty –A finite element study
title_full_unstemmed Evaluation for the causes of a femoral neck fracture in hip resurfacing arthroplasty –A finite element study
title_sort evaluation for the causes of a femoral neck fracture in hip resurfacing arthroplasty –a finite element study
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/m8gw44
work_keys_str_mv AT shouhaochen evaluationforthecausesofafemoralneckfractureinhipresurfacingarthroplastyafiniteelementstudy
AT chénshǒuháo evaluationforthecausesofafemoralneckfractureinhipresurfacingarthroplastyafiniteelementstudy
AT shouhaochen réngōngkuānguānjiébiǎomiànzhìhuànshùgǔgǔjǐnggǔzhéyùfángzhīyánjiū
AT chénshǒuháo réngōngkuānguānjiébiǎomiànzhìhuànshùgǔgǔjǐnggǔzhéyùfángzhīyánjiū
_version_ 1719105534048600064