On-Site Inspection and Management of Air Pollution Control Devices for Stationary Sources

碩士 === 國立臺北科技大學 === 環境工程與管理研究所 === 100 === A well-designed air pollution prevention device can successfully decrease the amount of air pollution as well as increasing the production efficiency. It is also considered as an easier approach in pollution reduction. According to operation laws, regular i...

Full description

Bibliographic Details
Main Authors: Yang-TI Su, 蘇暘堤
Other Authors: Yu-Min Chang
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/cd6ed2
id ndltd-TW-100TIT05087006
record_format oai_dc
spelling ndltd-TW-100TIT050870062019-05-15T20:51:51Z http://ndltd.ncl.edu.tw/handle/cd6ed2 On-Site Inspection and Management of Air Pollution Control Devices for Stationary Sources 固定污染源空氣污染防制成效實場查核與管制之研究 Yang-TI Su 蘇暘堤 碩士 國立臺北科技大學 環境工程與管理研究所 100 A well-designed air pollution prevention device can successfully decrease the amount of air pollution as well as increasing the production efficiency. It is also considered as an easier approach in pollution reduction. According to operation laws, regular inspection is required to stationary pollution sources, while advices or penalty is given to those not qualified. Since the inspection is implemented on a periodical basis, the quality of prevention equipments is essential to the effectiveness of pollution process. The current research aims at delivering a parametric study on the device efficiency based on the theoretical prediction and on-site measurement to five factories of distinct processes. Pollution concentrations before and after the measurement devices are taken from the aforementioned factories according to EPA (Environmental Protection Administration) released standards, such as NIEA A413.74C,A101.73C and A723.72C. These results are served as a reference to the implemention of stationary pollution control. Research results show that no siginificant difficicney is observed between the realistic measurement and theoretical prediction of the prevention devices. For example, WS-1、WS-3、WS-4 yields realistic efficiency as 79.18%, 45.8%, and 93.6%, while the theoretical prediction are 83.53%, 48.36%, and 96.28% respectively. However, both of these results still fall behind the regulations,Considering the factors affecting equipment efficiency, decreasing the pressure of a wet scrubber to a certain ragne increases the liquid-gas ratio and nozzle pressure. Additionally, changing the type of filter medium and spray height remarkably enlarges the removal efficiency to gasous pollutants. To bag houses, choosing filter bags with higher parameter bears better removal efficiency to particulate pollutants. For instance, the removal efficiency of BH with filter fiber parameter (σ)=1000m-1 and t=5min yields removal efficiency up to 92%. The following control strategies to stationary pollution sources are then drawn from the results of current study. 1. Careful control and inspection per pollution components and percentage. 2. Careful examination and verification to equipment specification. 3. Enforcement to the management and inspection of permitted values. 4. Enforcement and implementation to the operation manual of prevention equipments. 5. Proper adjustment to the period of inspection. 6. Implementation to the automatic inspection equipments. Yu-Min Chang 章裕民 2012 學位論文 ; thesis 133 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺北科技大學 === 環境工程與管理研究所 === 100 === A well-designed air pollution prevention device can successfully decrease the amount of air pollution as well as increasing the production efficiency. It is also considered as an easier approach in pollution reduction. According to operation laws, regular inspection is required to stationary pollution sources, while advices or penalty is given to those not qualified. Since the inspection is implemented on a periodical basis, the quality of prevention equipments is essential to the effectiveness of pollution process. The current research aims at delivering a parametric study on the device efficiency based on the theoretical prediction and on-site measurement to five factories of distinct processes. Pollution concentrations before and after the measurement devices are taken from the aforementioned factories according to EPA (Environmental Protection Administration) released standards, such as NIEA A413.74C,A101.73C and A723.72C. These results are served as a reference to the implemention of stationary pollution control. Research results show that no siginificant difficicney is observed between the realistic measurement and theoretical prediction of the prevention devices. For example, WS-1、WS-3、WS-4 yields realistic efficiency as 79.18%, 45.8%, and 93.6%, while the theoretical prediction are 83.53%, 48.36%, and 96.28% respectively. However, both of these results still fall behind the regulations,Considering the factors affecting equipment efficiency, decreasing the pressure of a wet scrubber to a certain ragne increases the liquid-gas ratio and nozzle pressure. Additionally, changing the type of filter medium and spray height remarkably enlarges the removal efficiency to gasous pollutants. To bag houses, choosing filter bags with higher parameter bears better removal efficiency to particulate pollutants. For instance, the removal efficiency of BH with filter fiber parameter (σ)=1000m-1 and t=5min yields removal efficiency up to 92%. The following control strategies to stationary pollution sources are then drawn from the results of current study. 1. Careful control and inspection per pollution components and percentage. 2. Careful examination and verification to equipment specification. 3. Enforcement to the management and inspection of permitted values. 4. Enforcement and implementation to the operation manual of prevention equipments. 5. Proper adjustment to the period of inspection. 6. Implementation to the automatic inspection equipments.
author2 Yu-Min Chang
author_facet Yu-Min Chang
Yang-TI Su
蘇暘堤
author Yang-TI Su
蘇暘堤
spellingShingle Yang-TI Su
蘇暘堤
On-Site Inspection and Management of Air Pollution Control Devices for Stationary Sources
author_sort Yang-TI Su
title On-Site Inspection and Management of Air Pollution Control Devices for Stationary Sources
title_short On-Site Inspection and Management of Air Pollution Control Devices for Stationary Sources
title_full On-Site Inspection and Management of Air Pollution Control Devices for Stationary Sources
title_fullStr On-Site Inspection and Management of Air Pollution Control Devices for Stationary Sources
title_full_unstemmed On-Site Inspection and Management of Air Pollution Control Devices for Stationary Sources
title_sort on-site inspection and management of air pollution control devices for stationary sources
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/cd6ed2
work_keys_str_mv AT yangtisu onsiteinspectionandmanagementofairpollutioncontroldevicesforstationarysources
AT sūyángdī onsiteinspectionandmanagementofairpollutioncontroldevicesforstationarysources
AT yangtisu gùdìngwūrǎnyuánkōngqìwūrǎnfángzhìchéngxiàoshíchǎngcháhéyǔguǎnzhìzhīyánjiū
AT sūyángdī gùdìngwūrǎnyuánkōngqìwūrǎnfángzhìchéngxiàoshíchǎngcháhéyǔguǎnzhìzhīyánjiū
_version_ 1719105297543331840