Evaluation of Knee Ligament Measurement System With Internal/External And Varus/Valgus Rotation Functions

碩士 === 國立臺灣海洋大學 === 機械與機電工程學系 === 100 === The Knee ligament broken of the fission damage is the common sports damage in domestic and overseas. It’s not confined to sportsman, that is affect of the wide range in aspects. Because the Structure effect of anterior cruciate ligament (ACL), the laceration...

Full description

Bibliographic Details
Main Authors: Hsiao-Man Hsu, 許筱曼
Other Authors: Chen-chou Lin
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/50521797605530569196
id ndltd-TW-100NTOU5491010
record_format oai_dc
spelling ndltd-TW-100NTOU54910102015-10-13T22:51:53Z http://ndltd.ncl.edu.tw/handle/50521797605530569196 Evaluation of Knee Ligament Measurement System With Internal/External And Varus/Valgus Rotation Functions 具內外轉與內外翻功能之膝關節韌帶鬆弛度量測系統評估 Hsiao-Man Hsu 許筱曼 碩士 國立臺灣海洋大學 機械與機電工程學系 100 The Knee ligament broken of the fission damage is the common sports damage in domestic and overseas. It’s not confined to sportsman, that is affect of the wide range in aspects. Because the Structure effect of anterior cruciate ligament (ACL), the laceration is not suitable to carry out remedial. Therefore, anterior cruciate ligament reconstruction is one of the most common surgical. At present, the majority of reconstruction can be made use of endoscopic surgery. Although previous single-beam fixed bundled in the recovery knee function of improved, but for the stability of the knee structure is not enough, in some cases will be unstable or displacement, and may even develop into the degenerative joint. Through several vitro exercise testing、flip and rotate the test, the results showed that rely on single-bundle reconstruction is not sufficient to control the rotation and valgus torque on the knee load. In this study, develop of a can be measured knee rotation and turned inside and outside, in addition to through the instrument to quantify the knee laxity rotation test data, can be more clearly understand the and compare with results for anterior cruciate ligament injury and normal knee, and can verify whether the operation succeeded in reconstructing the knee. The main function include:The ACL, PCL, MCL, LCL of Knee ligament conducted varus and valgus angulation , internal and external rotation measurements. High sensitivity and data reproducibility. Operation easier and reduce the impact of the user experience. With good evidence that the consideration due to the interface of the project design. Chen-chou Lin 林鎮洲 2012 學位論文 ; thesis 118 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立臺灣海洋大學 === 機械與機電工程學系 === 100 === The Knee ligament broken of the fission damage is the common sports damage in domestic and overseas. It’s not confined to sportsman, that is affect of the wide range in aspects. Because the Structure effect of anterior cruciate ligament (ACL), the laceration is not suitable to carry out remedial. Therefore, anterior cruciate ligament reconstruction is one of the most common surgical. At present, the majority of reconstruction can be made use of endoscopic surgery. Although previous single-beam fixed bundled in the recovery knee function of improved, but for the stability of the knee structure is not enough, in some cases will be unstable or displacement, and may even develop into the degenerative joint. Through several vitro exercise testing、flip and rotate the test, the results showed that rely on single-bundle reconstruction is not sufficient to control the rotation and valgus torque on the knee load. In this study, develop of a can be measured knee rotation and turned inside and outside, in addition to through the instrument to quantify the knee laxity rotation test data, can be more clearly understand the and compare with results for anterior cruciate ligament injury and normal knee, and can verify whether the operation succeeded in reconstructing the knee. The main function include:The ACL, PCL, MCL, LCL of Knee ligament conducted varus and valgus angulation , internal and external rotation measurements. High sensitivity and data reproducibility. Operation easier and reduce the impact of the user experience. With good evidence that the consideration due to the interface of the project design.
author2 Chen-chou Lin
author_facet Chen-chou Lin
Hsiao-Man Hsu
許筱曼
author Hsiao-Man Hsu
許筱曼
spellingShingle Hsiao-Man Hsu
許筱曼
Evaluation of Knee Ligament Measurement System With Internal/External And Varus/Valgus Rotation Functions
author_sort Hsiao-Man Hsu
title Evaluation of Knee Ligament Measurement System With Internal/External And Varus/Valgus Rotation Functions
title_short Evaluation of Knee Ligament Measurement System With Internal/External And Varus/Valgus Rotation Functions
title_full Evaluation of Knee Ligament Measurement System With Internal/External And Varus/Valgus Rotation Functions
title_fullStr Evaluation of Knee Ligament Measurement System With Internal/External And Varus/Valgus Rotation Functions
title_full_unstemmed Evaluation of Knee Ligament Measurement System With Internal/External And Varus/Valgus Rotation Functions
title_sort evaluation of knee ligament measurement system with internal/external and varus/valgus rotation functions
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/50521797605530569196
work_keys_str_mv AT hsiaomanhsu evaluationofkneeligamentmeasurementsystemwithinternalexternalandvarusvalgusrotationfunctions
AT xǔxiǎomàn evaluationofkneeligamentmeasurementsystemwithinternalexternalandvarusvalgusrotationfunctions
AT hsiaomanhsu jùnèiwàizhuǎnyǔnèiwàifāngōngnéngzhīxīguānjiérèndàisōngchídùliàngcèxìtǒngpínggū
AT xǔxiǎomàn jùnèiwàizhuǎnyǔnèiwàifāngōngnéngzhīxīguānjiérèndàisōngchídùliàngcèxìtǒngpínggū
_version_ 1718081254068322304