Studies on the performance improvement of an integrated apparatus for concentration of ferrous debris and viscosity of lubricant

碩士 === 國立中山大學 === 機械與機電工程學系研究所 === 100 === Lubrication is the lifeblood of mechanical device during the operating conditions, so that the lubricating oil detection becomes one of an important modern technology. The operator can be as early as possible to know whether the abnormal wear occurs by dete...

Full description

Bibliographic Details
Main Authors: Ji-Ying Lin, 林奇穎
Other Authors: Rong-Tsong Lee
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/51037462515422433030
id ndltd-TW-100NSYS5490092
record_format oai_dc
spelling ndltd-TW-100NSYS54900922015-10-13T21:22:20Z http://ndltd.ncl.edu.tw/handle/51037462515422433030 Studies on the performance improvement of an integrated apparatus for concentration of ferrous debris and viscosity of lubricant 檢測潤滑油中鐵顆粒濃度與黏度的整合裝置之性能改善研究 Ji-Ying Lin 林奇穎 碩士 國立中山大學 機械與機電工程學系研究所 100 Lubrication is the lifeblood of mechanical device during the operating conditions, so that the lubricating oil detection becomes one of an important modern technology. The operator can be as early as possible to know whether the abnormal wear occurs by detecting concentration of ferrous debris in the lubricating oil. Detecting the viscosity of lubricating oil can also allow the operator to monitor the deterioration degree of lubricating oil due to environmental factors, in order to ensure whether the lubricating oil losing its effectiveness. Our laboratory previously developed a prototype of integrated apparatus for detecting the concentration of ferrous debris and the viscosity of lubricant in a single process. This study focuses on improving this prototype, so that the apparatus possesses a LCD displayer and commercialization. The design of the integrated apparatus contains a sampling unit, a measurement unit of the ferrous debris concentration, a measurement unit of the viscosity, a data acquisition system, and LCD displayer panel. In measurement unit of the ferrous debris concentration, Hall IC is used as a sensor to measure the concentration of ferrous debris by detecting the change of magnetic flux density between the magnetic poles due to the stacking of ferrous debris. In the measurement unit of the viscosity of the lubricating oils, the piston is used to squeeze the oil into the tank to measure the viscosity by detecting the load. These two units are integrated into a measuring device, and there is no interference between the values measured by the Hall IC and the load cell. Finally, these two signals are fed to a personal computer for data analysis to obtain the concentration of ferrous debris and the viscosity of lubricant. Consequently, the operator can directly observe the measured results. Rong-Tsong Lee Yuang-Cherng Chiou 李榮宗 邱源成 2012 學位論文 ; thesis 88 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中山大學 === 機械與機電工程學系研究所 === 100 === Lubrication is the lifeblood of mechanical device during the operating conditions, so that the lubricating oil detection becomes one of an important modern technology. The operator can be as early as possible to know whether the abnormal wear occurs by detecting concentration of ferrous debris in the lubricating oil. Detecting the viscosity of lubricating oil can also allow the operator to monitor the deterioration degree of lubricating oil due to environmental factors, in order to ensure whether the lubricating oil losing its effectiveness. Our laboratory previously developed a prototype of integrated apparatus for detecting the concentration of ferrous debris and the viscosity of lubricant in a single process. This study focuses on improving this prototype, so that the apparatus possesses a LCD displayer and commercialization. The design of the integrated apparatus contains a sampling unit, a measurement unit of the ferrous debris concentration, a measurement unit of the viscosity, a data acquisition system, and LCD displayer panel. In measurement unit of the ferrous debris concentration, Hall IC is used as a sensor to measure the concentration of ferrous debris by detecting the change of magnetic flux density between the magnetic poles due to the stacking of ferrous debris. In the measurement unit of the viscosity of the lubricating oils, the piston is used to squeeze the oil into the tank to measure the viscosity by detecting the load. These two units are integrated into a measuring device, and there is no interference between the values measured by the Hall IC and the load cell. Finally, these two signals are fed to a personal computer for data analysis to obtain the concentration of ferrous debris and the viscosity of lubricant. Consequently, the operator can directly observe the measured results.
author2 Rong-Tsong Lee
author_facet Rong-Tsong Lee
Ji-Ying Lin
林奇穎
author Ji-Ying Lin
林奇穎
spellingShingle Ji-Ying Lin
林奇穎
Studies on the performance improvement of an integrated apparatus for concentration of ferrous debris and viscosity of lubricant
author_sort Ji-Ying Lin
title Studies on the performance improvement of an integrated apparatus for concentration of ferrous debris and viscosity of lubricant
title_short Studies on the performance improvement of an integrated apparatus for concentration of ferrous debris and viscosity of lubricant
title_full Studies on the performance improvement of an integrated apparatus for concentration of ferrous debris and viscosity of lubricant
title_fullStr Studies on the performance improvement of an integrated apparatus for concentration of ferrous debris and viscosity of lubricant
title_full_unstemmed Studies on the performance improvement of an integrated apparatus for concentration of ferrous debris and viscosity of lubricant
title_sort studies on the performance improvement of an integrated apparatus for concentration of ferrous debris and viscosity of lubricant
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/51037462515422433030
work_keys_str_mv AT jiyinglin studiesontheperformanceimprovementofanintegratedapparatusforconcentrationofferrousdebrisandviscosityoflubricant
AT línqíyǐng studiesontheperformanceimprovementofanintegratedapparatusforconcentrationofferrousdebrisandviscosityoflubricant
AT jiyinglin jiǎncèrùnhuáyóuzhōngtiěkēlìnóngdùyǔniándùdezhěnghézhuāngzhìzhīxìngnénggǎishànyánjiū
AT línqíyǐng jiǎncèrùnhuáyóuzhōngtiěkēlìnóngdùyǔniándùdezhěnghézhuāngzhìzhīxìngnénggǎishànyánjiū
_version_ 1718061496454348800