Optimization of contrast and signal homogeneity for high resolution 3D MRI of human brain at 1.5 Tesla

碩士 === 國立中山大學 === 電機工程學系研究所 === 100 === The inhomogeneous B1 field at higher main fields (B0) becomes more serious, leading to unsatisfactory MR image quality. To improve the signal homogeneity of routinely used T1-weighted image, usually acquired by a well-known sequence, Magnetization Prepared Ra...

Full description

Bibliographic Details
Main Authors: Shi-jia Wu, 吳昔嘉
Other Authors: Tzu-Chao Chuang
Format: Others
Language:zh-TW
Published: 2011
Online Access:http://ndltd.ncl.edu.tw/handle/33448198246420141406
id ndltd-TW-100NSYS5442009
record_format oai_dc
spelling ndltd-TW-100NSYS54420092015-10-13T21:17:52Z http://ndltd.ncl.edu.tw/handle/33448198246420141406 Optimization of contrast and signal homogeneity for high resolution 3D MRI of human brain at 1.5 Tesla 三維高解析度人腦磁共振影像:對比與訊號均勻度在1.5 T磁場下之最佳化研究 Shi-jia Wu 吳昔嘉 碩士 國立中山大學 電機工程學系研究所 100 The inhomogeneous B1 field at higher main fields (B0) becomes more serious, leading to unsatisfactory MR image quality. To improve the signal homogeneity of routinely used T1-weighted image, usually acquired by a well-known sequence, Magnetization Prepared Rapid Acquisition Gradient Echo (MPRAGE), a new pulse sequence, Magnetization Prepared 2 Rapid Acquisition Gradient Echoes (MP2RAGE), was proposed in 2009. This technique acquires two sets of high-resolution three- dimentional images at different inversion times after a series of inversion pulses. After any of two simple calculations of the raw images (Ratio or MP2RAGE reconstruction), the output volume was obtained with dramatically reduced spatial inhomogenuity of MR signal. In this study, the contrast-to-noise ratio (CNR) optimation at 3 T was implemented independently to reproduce the previous results of other group. After that, the simulation of scanning parameters was done to optimize CNR of brain tissue at 1.5 T according to different encoding methods, different pulse sequences, and different reconstruction algorithms. Phantom and human experiments were carried on a 1.5 T scanner for further validation. The results of phantom experiment showed that both MP2RAGE and Ratio reconstructions can achiever better B1 homogeneity than MPRAGE, even with the vendor-equipped correction packages, SCIC and PURE. In addition, the agreement was made between simulation and in-vivo imaging that MP2RAGE provides higher CNR than Ratio when centric encoding also outduels linear encoding. Tzu-Chao Chuang 莊子肇 2011 學位論文 ; thesis 103 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中山大學 === 電機工程學系研究所 === 100 === The inhomogeneous B1 field at higher main fields (B0) becomes more serious, leading to unsatisfactory MR image quality. To improve the signal homogeneity of routinely used T1-weighted image, usually acquired by a well-known sequence, Magnetization Prepared Rapid Acquisition Gradient Echo (MPRAGE), a new pulse sequence, Magnetization Prepared 2 Rapid Acquisition Gradient Echoes (MP2RAGE), was proposed in 2009. This technique acquires two sets of high-resolution three- dimentional images at different inversion times after a series of inversion pulses. After any of two simple calculations of the raw images (Ratio or MP2RAGE reconstruction), the output volume was obtained with dramatically reduced spatial inhomogenuity of MR signal. In this study, the contrast-to-noise ratio (CNR) optimation at 3 T was implemented independently to reproduce the previous results of other group. After that, the simulation of scanning parameters was done to optimize CNR of brain tissue at 1.5 T according to different encoding methods, different pulse sequences, and different reconstruction algorithms. Phantom and human experiments were carried on a 1.5 T scanner for further validation. The results of phantom experiment showed that both MP2RAGE and Ratio reconstructions can achiever better B1 homogeneity than MPRAGE, even with the vendor-equipped correction packages, SCIC and PURE. In addition, the agreement was made between simulation and in-vivo imaging that MP2RAGE provides higher CNR than Ratio when centric encoding also outduels linear encoding.
author2 Tzu-Chao Chuang
author_facet Tzu-Chao Chuang
Shi-jia Wu
吳昔嘉
author Shi-jia Wu
吳昔嘉
spellingShingle Shi-jia Wu
吳昔嘉
Optimization of contrast and signal homogeneity for high resolution 3D MRI of human brain at 1.5 Tesla
author_sort Shi-jia Wu
title Optimization of contrast and signal homogeneity for high resolution 3D MRI of human brain at 1.5 Tesla
title_short Optimization of contrast and signal homogeneity for high resolution 3D MRI of human brain at 1.5 Tesla
title_full Optimization of contrast and signal homogeneity for high resolution 3D MRI of human brain at 1.5 Tesla
title_fullStr Optimization of contrast and signal homogeneity for high resolution 3D MRI of human brain at 1.5 Tesla
title_full_unstemmed Optimization of contrast and signal homogeneity for high resolution 3D MRI of human brain at 1.5 Tesla
title_sort optimization of contrast and signal homogeneity for high resolution 3d mri of human brain at 1.5 tesla
publishDate 2011
url http://ndltd.ncl.edu.tw/handle/33448198246420141406
work_keys_str_mv AT shijiawu optimizationofcontrastandsignalhomogeneityforhighresolution3dmriofhumanbrainat15tesla
AT wúxījiā optimizationofcontrastandsignalhomogeneityforhighresolution3dmriofhumanbrainat15tesla
AT shijiawu sānwéigāojiěxīdùrénnǎocígòngzhènyǐngxiàngduìbǐyǔxùnhàojūnyúndùzài15tcíchǎngxiàzhīzuìjiāhuàyánjiū
AT wúxījiā sānwéigāojiěxīdùrénnǎocígòngzhènyǐngxiàngduìbǐyǔxùnhàojūnyúndùzài15tcíchǎngxiàzhīzuìjiāhuàyánjiū
_version_ 1718060553391308800