Validity of cardiorespiratory fitness field tests applied in elementary obese male students

碩士 === 國立新竹教育大學 === 人資處體育碩士專班 === 100 === Objective: Investigate and compare the validity of cardiorespiratory fitness tests for elementary obese male students, including 600-meter running, 800-meter running, 9-minute running and 6-minute walk tests. Methods: Eighteen elementary obese male students...

Full description

Bibliographic Details
Main Authors: Lin Chuan-Erh, 林全二
Other Authors: Lin Kuei-Fu
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/98917912639935475975
id ndltd-TW-100NHCT5567017
record_format oai_dc
spelling ndltd-TW-100NHCT55670172016-02-21T04:19:35Z http://ndltd.ncl.edu.tw/handle/98917912639935475975 Validity of cardiorespiratory fitness field tests applied in elementary obese male students 國小肥胖學童心肺耐力實地測量法之效度分析 Lin Chuan-Erh 林全二 碩士 國立新竹教育大學 人資處體育碩士專班 100 Objective: Investigate and compare the validity of cardiorespiratory fitness tests for elementary obese male students, including 600-meter running, 800-meter running, 9-minute running and 6-minute walk tests. Methods: Eighteen elementary obese male students aged 11-12yrs were recruited in the study. Each participant firstly completed an incremental exercise test to evaluate the maximal oxygen consumption (VO2max), and following four cardiorespiratory field tests, including the 600-m and 800-m running, 9-minute run/walk test and 6-minute walk test. The time required or the distances finished in the tests were defined as cardiorespiratory performance. Collected data were analyzed by Pearson's product-moment correlation to verify the correlation between VO2max and each of the four field tests performance. Besides, the coefficient of determination (r2) derived from linear regression analysis was defined as validity. Results: 1) 600-meter running, 800-meter running, 9-minute running and 6-minute walk test were significantly correlated to VO2max respectively (r=-.78, r=-.78, r=.70, r=.60, p<.05). 2) The coefficient of determination (r2) were 0.60、0.61、0.49 and 0.36, while the standard error of estimates (SEE) were 3.34, 3.32, 3.78 and 4.27. Conclusion: All the four tests were effective in evaluating the cardiorespiratory fitness of elementary obese male students. In terms of physiological characteristics and time efficiency, the 600-meter running test was recommended for elementary obese male students. Lin Kuei-Fu 林貴福 2012 學位論文 ; thesis 36 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立新竹教育大學 === 人資處體育碩士專班 === 100 === Objective: Investigate and compare the validity of cardiorespiratory fitness tests for elementary obese male students, including 600-meter running, 800-meter running, 9-minute running and 6-minute walk tests. Methods: Eighteen elementary obese male students aged 11-12yrs were recruited in the study. Each participant firstly completed an incremental exercise test to evaluate the maximal oxygen consumption (VO2max), and following four cardiorespiratory field tests, including the 600-m and 800-m running, 9-minute run/walk test and 6-minute walk test. The time required or the distances finished in the tests were defined as cardiorespiratory performance. Collected data were analyzed by Pearson's product-moment correlation to verify the correlation between VO2max and each of the four field tests performance. Besides, the coefficient of determination (r2) derived from linear regression analysis was defined as validity. Results: 1) 600-meter running, 800-meter running, 9-minute running and 6-minute walk test were significantly correlated to VO2max respectively (r=-.78, r=-.78, r=.70, r=.60, p<.05). 2) The coefficient of determination (r2) were 0.60、0.61、0.49 and 0.36, while the standard error of estimates (SEE) were 3.34, 3.32, 3.78 and 4.27. Conclusion: All the four tests were effective in evaluating the cardiorespiratory fitness of elementary obese male students. In terms of physiological characteristics and time efficiency, the 600-meter running test was recommended for elementary obese male students.
author2 Lin Kuei-Fu
author_facet Lin Kuei-Fu
Lin Chuan-Erh
林全二
author Lin Chuan-Erh
林全二
spellingShingle Lin Chuan-Erh
林全二
Validity of cardiorespiratory fitness field tests applied in elementary obese male students
author_sort Lin Chuan-Erh
title Validity of cardiorespiratory fitness field tests applied in elementary obese male students
title_short Validity of cardiorespiratory fitness field tests applied in elementary obese male students
title_full Validity of cardiorespiratory fitness field tests applied in elementary obese male students
title_fullStr Validity of cardiorespiratory fitness field tests applied in elementary obese male students
title_full_unstemmed Validity of cardiorespiratory fitness field tests applied in elementary obese male students
title_sort validity of cardiorespiratory fitness field tests applied in elementary obese male students
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/98917912639935475975
work_keys_str_mv AT linchuanerh validityofcardiorespiratoryfitnessfieldtestsappliedinelementaryobesemalestudents
AT línquánèr validityofcardiorespiratoryfitnessfieldtestsappliedinelementaryobesemalestudents
AT linchuanerh guóxiǎoféipàngxuétóngxīnfèinàilìshídecèliàngfǎzhīxiàodùfēnxī
AT línquánèr guóxiǎoféipàngxuétóngxīnfèinàilìshídecèliàngfǎzhīxiàodùfēnxī
_version_ 1718192107833786368