Design and Implementation of a 3kW Wind Turbine Power Factor Corrector

碩士 === 國立彰化師範大學 === 電機工程學系 === 100 === This thesis develops a wind turbine power factor corrector. It is composed of a three-phase power factor corrector and a output voltage regulation controller. It can realize the function of the wind turbine power factor correction, reducing current total harmon...

Full description

Bibliographic Details
Main Authors: Shih-Chieh Hsieh, 謝士傑
Other Authors: Liang-Rui Chen
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/02973720777009416013
id ndltd-TW-100NCUE5442060
record_format oai_dc
spelling ndltd-TW-100NCUE54420602015-10-13T21:28:01Z http://ndltd.ncl.edu.tw/handle/02973720777009416013 Design and Implementation of a 3kW Wind Turbine Power Factor Corrector 3kW風力發電機功率因數修正器之研製 Shih-Chieh Hsieh 謝士傑 碩士 國立彰化師範大學 電機工程學系 100 This thesis develops a wind turbine power factor corrector. It is composed of a three-phase power factor corrector and a output voltage regulation controller. It can realize the function of the wind turbine power factor correction, reducing current total harmonic distortion and output voltage regulation. Three-phase power factor corrector uses a full-controlled AC/DC converter with a current controller. The output voltage regulation controller is achieved by the UC3854 internal multiplier. The power factor correction with fast dynamic response can improve the efficiency and operation noise of wind turbine power generation. Finally, a 3000W wind generator power factor corrector is designed and implemented to verify the feasibility of the proposed system. The experimental results show that the proposed wind turbine power factor corrector can improve the power factor, the efficiency and the temperature rising of the wind turbine when the wind turbine operates at different wind speeds. Liang-Rui Chen 陳良瑞 2012 學位論文 ; thesis 71 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立彰化師範大學 === 電機工程學系 === 100 === This thesis develops a wind turbine power factor corrector. It is composed of a three-phase power factor corrector and a output voltage regulation controller. It can realize the function of the wind turbine power factor correction, reducing current total harmonic distortion and output voltage regulation. Three-phase power factor corrector uses a full-controlled AC/DC converter with a current controller. The output voltage regulation controller is achieved by the UC3854 internal multiplier. The power factor correction with fast dynamic response can improve the efficiency and operation noise of wind turbine power generation. Finally, a 3000W wind generator power factor corrector is designed and implemented to verify the feasibility of the proposed system. The experimental results show that the proposed wind turbine power factor corrector can improve the power factor, the efficiency and the temperature rising of the wind turbine when the wind turbine operates at different wind speeds.
author2 Liang-Rui Chen
author_facet Liang-Rui Chen
Shih-Chieh Hsieh
謝士傑
author Shih-Chieh Hsieh
謝士傑
spellingShingle Shih-Chieh Hsieh
謝士傑
Design and Implementation of a 3kW Wind Turbine Power Factor Corrector
author_sort Shih-Chieh Hsieh
title Design and Implementation of a 3kW Wind Turbine Power Factor Corrector
title_short Design and Implementation of a 3kW Wind Turbine Power Factor Corrector
title_full Design and Implementation of a 3kW Wind Turbine Power Factor Corrector
title_fullStr Design and Implementation of a 3kW Wind Turbine Power Factor Corrector
title_full_unstemmed Design and Implementation of a 3kW Wind Turbine Power Factor Corrector
title_sort design and implementation of a 3kw wind turbine power factor corrector
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/02973720777009416013
work_keys_str_mv AT shihchiehhsieh designandimplementationofa3kwwindturbinepowerfactorcorrector
AT xièshìjié designandimplementationofa3kwwindturbinepowerfactorcorrector
AT shihchiehhsieh 3kwfēnglìfādiànjīgōnglǜyīnshùxiūzhèngqìzhīyánzhì
AT xièshìjié 3kwfēnglìfādiànjīgōnglǜyīnshùxiūzhèngqìzhīyánzhì
_version_ 1718064997513297920