Real-time rigid fusion of liver computed tomograph and ultrasound images

碩士 === 國立中央大學 === 機械工程研究所 === 100 === Ultrasound scan is the most common way to detect the disease of liver diseases. Ultrasound imaging is real-time and non-invasive, but its image quality is poor and lack of spatial information. Therefore, subjective interpretation of ultrasound images may cause m...

Full description

Bibliographic Details
Main Authors: Shang-kun Li, 黎尚昆
Other Authors: Ching-shiow Tseng
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/39467708584306742777
id ndltd-TW-100NCU05489022
record_format oai_dc
spelling ndltd-TW-100NCU054890222015-10-13T21:22:21Z http://ndltd.ncl.edu.tw/handle/39467708584306742777 Real-time rigid fusion of liver computed tomograph and ultrasound images 肝臟電腦斷層影像與超音波影像即時剛性融合 Shang-kun Li 黎尚昆 碩士 國立中央大學 機械工程研究所 100 Ultrasound scan is the most common way to detect the disease of liver diseases. Ultrasound imaging is real-time and non-invasive, but its image quality is poor and lack of spatial information. Therefore, subjective interpretation of ultrasound images may cause misdiagnosis. On the other hand, computed tomography images have high quality. If CT and US images are scanned at similar respiration and posture status, the fusion of both images will be able to improve diagnosis quality and biopsy accuracy. Prior to ultrasound scan, the patient''s posture and respiration are monitored and controlled to have similar status as CT scan. Then the grabbed ultrasound images of ribs are processed to find the boundary of the ribs. Using the iterative closet point algorithm, the data of boundary points are then applied to complete surface registration with reconstructed 3D model of rib’s CT images and to obtain the transformation matrix between the two image frames. Experiments of image registration error assessment are performed with an anthropomorphic phantom and a human patient. The edge information of captured characteristics ultrasound images are transformed to CT image frame and compared with the same characteristics on the CT images to calculate their position errors. The results show that position error of anthropomorphic phantom experiment at the xy plane is 2.32mm and the z axis is 4.48mm while that of human patient is approximate 4mm. Since there is clear angular error, press of ultrasound probe on the patient during ultrasound scan may be the factor caused angular error. Ching-shiow Tseng 曾清秀 2012 學位論文 ; thesis 89 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立中央大學 === 機械工程研究所 === 100 === Ultrasound scan is the most common way to detect the disease of liver diseases. Ultrasound imaging is real-time and non-invasive, but its image quality is poor and lack of spatial information. Therefore, subjective interpretation of ultrasound images may cause misdiagnosis. On the other hand, computed tomography images have high quality. If CT and US images are scanned at similar respiration and posture status, the fusion of both images will be able to improve diagnosis quality and biopsy accuracy. Prior to ultrasound scan, the patient''s posture and respiration are monitored and controlled to have similar status as CT scan. Then the grabbed ultrasound images of ribs are processed to find the boundary of the ribs. Using the iterative closet point algorithm, the data of boundary points are then applied to complete surface registration with reconstructed 3D model of rib’s CT images and to obtain the transformation matrix between the two image frames. Experiments of image registration error assessment are performed with an anthropomorphic phantom and a human patient. The edge information of captured characteristics ultrasound images are transformed to CT image frame and compared with the same characteristics on the CT images to calculate their position errors. The results show that position error of anthropomorphic phantom experiment at the xy plane is 2.32mm and the z axis is 4.48mm while that of human patient is approximate 4mm. Since there is clear angular error, press of ultrasound probe on the patient during ultrasound scan may be the factor caused angular error.
author2 Ching-shiow Tseng
author_facet Ching-shiow Tseng
Shang-kun Li
黎尚昆
author Shang-kun Li
黎尚昆
spellingShingle Shang-kun Li
黎尚昆
Real-time rigid fusion of liver computed tomograph and ultrasound images
author_sort Shang-kun Li
title Real-time rigid fusion of liver computed tomograph and ultrasound images
title_short Real-time rigid fusion of liver computed tomograph and ultrasound images
title_full Real-time rigid fusion of liver computed tomograph and ultrasound images
title_fullStr Real-time rigid fusion of liver computed tomograph and ultrasound images
title_full_unstemmed Real-time rigid fusion of liver computed tomograph and ultrasound images
title_sort real-time rigid fusion of liver computed tomograph and ultrasound images
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/39467708584306742777
work_keys_str_mv AT shangkunli realtimerigidfusionoflivercomputedtomographandultrasoundimages
AT líshàngkūn realtimerigidfusionoflivercomputedtomographandultrasoundimages
AT shangkunli gānzàngdiànnǎoduàncéngyǐngxiàngyǔchāoyīnbōyǐngxiàngjíshígāngxìngrónghé
AT líshàngkūn gānzàngdiànnǎoduàncéngyǐngxiàngyǔchāoyīnbōyǐngxiàngjíshígāngxìngrónghé
_version_ 1718061265913380864