Evaluation on Thermal Spraying Applications of Boiler Tubes

碩士 === 國立交通大學 === 工學院產業安全與防災學程 === 100 === During the annual inspection in April 2007, one coal-fired power plant in Taiwan discovered that the thickness of the broiler’s tube wall was under the borderline. Because it was not the time yet for an overall inspection, this problem was handled by weldin...

Full description

Bibliographic Details
Main Authors: Huang, Wen-Hsuan, 黃汶軒
Other Authors: Fu, Wu-Shung
Format: Others
Language:zh-TW
Published: 2012
Online Access:http://ndltd.ncl.edu.tw/handle/27742482180152434794
id ndltd-TW-100NCTU5707081
record_format oai_dc
spelling ndltd-TW-100NCTU57070812016-03-28T04:20:38Z http://ndltd.ncl.edu.tw/handle/27742482180152434794 Evaluation on Thermal Spraying Applications of Boiler Tubes 鍋爐水牆管噴焊可行性評估 Huang, Wen-Hsuan 黃汶軒 碩士 國立交通大學 工學院產業安全與防災學程 100 During the annual inspection in April 2007, one coal-fired power plant in Taiwan discovered that the thickness of the broiler’s tube wall was under the borderline. Because it was not the time yet for an overall inspection, this problem was handled by welding. Later on in July 2008, this welded waterwall tube ruptured. The section of the broken tube was examined by observing the cross-section of the broken tube, testing the rigidity, and performing a microscopic metallographic analysis. The results suggested that this matter may be stress and corrosion induced rupture, and the stress here may be the residual stress from wielding. It was suggested that some cracks were formed at the internal wall of the starting or stopping end of welding. Once these cracks received water pressure inside the tube, the residual stress from welding and corrosion factors acted together and grew bigger. At the end, cracks were formed throughout the tube wall, causing the high pressure water inside the tube to spout and create more rupture. The objective of this study is to clarify causes for tube rupture using relevant tests and analyses. High velocity oxy fuel will be used to coat the surface of the wall of broiler tubes with WC/Co. This treatment will be followed by onsite testing. Three years later, the thickness of the sprayed surface will be compared for assessing the feasibility of giving broiler tubes comprehensive welding in the future. Fu, Wu-Shung 傅武雄 2012 學位論文 ; thesis 53 zh-TW
collection NDLTD
language zh-TW
format Others
sources NDLTD
description 碩士 === 國立交通大學 === 工學院產業安全與防災學程 === 100 === During the annual inspection in April 2007, one coal-fired power plant in Taiwan discovered that the thickness of the broiler’s tube wall was under the borderline. Because it was not the time yet for an overall inspection, this problem was handled by welding. Later on in July 2008, this welded waterwall tube ruptured. The section of the broken tube was examined by observing the cross-section of the broken tube, testing the rigidity, and performing a microscopic metallographic analysis. The results suggested that this matter may be stress and corrosion induced rupture, and the stress here may be the residual stress from wielding. It was suggested that some cracks were formed at the internal wall of the starting or stopping end of welding. Once these cracks received water pressure inside the tube, the residual stress from welding and corrosion factors acted together and grew bigger. At the end, cracks were formed throughout the tube wall, causing the high pressure water inside the tube to spout and create more rupture. The objective of this study is to clarify causes for tube rupture using relevant tests and analyses. High velocity oxy fuel will be used to coat the surface of the wall of broiler tubes with WC/Co. This treatment will be followed by onsite testing. Three years later, the thickness of the sprayed surface will be compared for assessing the feasibility of giving broiler tubes comprehensive welding in the future.
author2 Fu, Wu-Shung
author_facet Fu, Wu-Shung
Huang, Wen-Hsuan
黃汶軒
author Huang, Wen-Hsuan
黃汶軒
spellingShingle Huang, Wen-Hsuan
黃汶軒
Evaluation on Thermal Spraying Applications of Boiler Tubes
author_sort Huang, Wen-Hsuan
title Evaluation on Thermal Spraying Applications of Boiler Tubes
title_short Evaluation on Thermal Spraying Applications of Boiler Tubes
title_full Evaluation on Thermal Spraying Applications of Boiler Tubes
title_fullStr Evaluation on Thermal Spraying Applications of Boiler Tubes
title_full_unstemmed Evaluation on Thermal Spraying Applications of Boiler Tubes
title_sort evaluation on thermal spraying applications of boiler tubes
publishDate 2012
url http://ndltd.ncl.edu.tw/handle/27742482180152434794
work_keys_str_mv AT huangwenhsuan evaluationonthermalsprayingapplicationsofboilertubes
AT huángwènxuān evaluationonthermalsprayingapplicationsofboilertubes
AT huangwenhsuan guōlúshuǐqiángguǎnpēnhànkěxíngxìngpínggū
AT huángwènxuān guōlúshuǐqiángguǎnpēnhànkěxíngxìngpínggū
_version_ 1718213727571935232